EARUMZDQ SCT-T10

EARUMZDQ PC311 Smart Two-Way Bilateral WiFi Energy Meter Instruction Manual

Brand: EARUMZDQ | Model: SCT-T10

Product Overview

The EARUMZDQ PC311 Smart Two-Way Bilateral WiFi Energy Meter is designed to monitor electricity consumption and generation in both AC110V and 220V systems. It provides real-time data on voltage, current, active power, and power factor, accessible via the Tuya or Smart Life mobile applications. This device is ideal for tracking energy usage from the city grid and power generated by solar PV systems, offering comprehensive insights into your home's energy flow.

EARUMZDQ PC311 Smart Energy Meter with two 80A CT clamps

Image: The EARUMZDQ PC311 Smart Energy Meter module connected to two 80A Current Transformer (CT) clamps.

Key Features:

What's in the Box

Setup and Installation

1. Physical Installation

The PC311 module is designed for 35MM DIN RAIL installation. Ensure the device is installed in a location with stable 2.4G WiFi coverage and within the specified ambient temperature and humidity ranges.

Technical specifications and component diagram of the energy meter

Image: Diagram showing the PC311 module with AC input, CT clamp connections, LED indicator, and reset button, along with mounting bracket details.

2. Wiring Diagram

Proper wiring is crucial for accurate measurement. Refer to the diagrams below for connecting the CT clamps based on your monitoring needs (consumption from grid, generation from solar, or load monitoring).

Wiring diagram for energy meter with CT clamps for grid, inverter, and load

Image: Comprehensive wiring diagram illustrating how to connect CT clamps for measuring energy from the grid, from an inverter (solar generation), and from a specific load.

Important: The direction of the CT clamp matters for accurate readings. For measuring energy generation, the arrow on the clamp should face the inverter. For measuring consumption from the grid, install the CT on the leads coming from your mains.

Detailed wiring diagrams for measuring energy generation and grid consumption

Image: Two separate wiring diagrams. The top diagram shows CT2 connected to monitor energy generation from an inverter. The bottom diagram shows CT1 connected to monitor energy consumption from the grid, with arrows indicating current direction for 'From Grid' and 'To Grid' energy accumulation.

3. App Connection (Tuya/Smart Life)

The device connects to your home's 2.4G WiFi network. 5G WiFi is not supported. Follow these steps to pair the device with the Tuya or Smart Life app:

  1. Download and install the Tuya Smart or Smart Life app from your mobile app store.
  2. Register or log in to your account.
  3. Power on the PC311 module. The LED indicator should blink, indicating pairing mode.
  4. Open the app, tap "Add Device" or the "+" icon.
  5. The app should automatically discover the device (PC311_TY). Tap "Add".
  6. Enter your 2.4G WiFi network name and password when prompted.
  7. Wait for the device to connect. Once connected, you can rename it and start monitoring.

Video: A demonstration of the PC311 App Operation, showing the process of adding the device to the Tuya/Smart Life app and navigating through its features.

Operating Instructions

Monitoring Energy Data

Once connected, the Tuya or Smart Life app provides a comprehensive interface for monitoring your energy data. The data refreshes every 15 seconds.

App interface showing two-phase current measurement and energy overview

Image: Screenshots of the mobile application interface, demonstrating how to view total forward energy, total generation, and detailed information for Circuit 1 and Circuit 2, including forward and reverse current measurements.

App interface showing daily energy consumption graph

Image: A screenshot of the app displaying a daily energy consumption graph, showing total forward energy and total generation over time, with example appliances in the background.

Automation and Scene Creation

Leverage the "Tap-to-Run" and automation features within the Tuya/Smart Life app to integrate the energy meter with other smart devices. For example, you can set up automations based on energy consumption thresholds.

Maintenance

The EARUMZDQ PC311 energy meter requires minimal maintenance. Ensure the device is kept within its specified operating environment conditions:

Regularly check the physical connections of the CT clamps and power input to ensure they are secure. Keep the device clean and free from dust and moisture.

Troubleshooting

ProblemPossible CauseSolution
Device not connecting to WiFi.Incorrect WiFi password; 5G WiFi network; device too far from router; router issues.
  • Verify WiFi password.
  • Ensure you are connecting to a 2.4G WiFi network (5G is not supported).
  • Move the device closer to the WiFi router.
  • Restart your WiFi router.
Inaccurate energy readings.Incorrect CT clamp direction; loose CT clamp connection; faulty CT clamp.
  • Check the direction of the CT clamp (arrow should point towards the load/inverter as per wiring diagram).
  • Ensure CT clamps are securely closed around the wire.
  • Verify wiring connections to the module.
  • If issues persist, contact customer support.
No data displayed in the app.Device offline; app synchronization issue; power supply issue.
  • Check if the device's LED indicator is solid (connected).
  • Ensure the device has stable power.
  • Restart the app.
  • If the device is offline, re-pair it with the app.

For further assistance, please refer to the manufacturer's support channels.

Specifications

FeatureDetail
Model NumberSCT-T10
Rated VoltageAC90-250V, 50/60HZ
Current Measure Range80A+80A (with 2PCS 80A CT Clamp Sensors)
CT Clamp Hole Diameter10MM
Wireless Connectivity2.4G WiFi (IEEE 802.11 b/g/n), Bluetooth 4.2 Low Energy
Compatible AppsTuya App, SMART LIFE App
Data Refresh Rate1 time / 15 seconds
Installation35MM DIN RAIL
Ambient Temperature Range-10°C ~ 55°C
Humidity≤90% non-condensing
Product Dimensions1.81 x 1.81 x 0.71 inches
Weight6 ounces
ManufacturerZHEJIANG EARU ELECTRONICS CO.,LTD
Country of OriginChina
Product dimensions of the energy meter and CT clamps

Image: Detailed diagram illustrating the dimensions of the PC311 module and the 80A CT clamp, including length, width, height, and CT hole diameter.

Warranty and Support

For warranty information and technical support, please contact EARUMZDQ directly through their official website or the contact information provided with your purchase. Keep your purchase receipt as proof of purchase.

Manufacturer: ZHEJIANG EARU ELECTRONICS CO.,LTD

Related Documents - SCT-T10

Preview Novatek-Electro SCT-T Series Current Transformer Operating Manual
Operating manual for Novatek-Electro SCT-T series split core current transformers, covering models SCT-T24, SCT-T36, and SCT-T50. Includes technical specifications, application, product description, safety guidelines, warranty, and contact information.
Preview SEL Fault Indicators, Sensors, and CTs: Product Overview and Applications
Explore Schweitzer Engineering Laboratories' comprehensive range of fault indicators, sensors, and current transformers (CTs) designed to enhance distribution system reliability, speed fault locating, and optimize outage management. Learn about products like SEL-FLT, SEL-FLR, SEL-AR, SEL-8301, and more.
Preview Magnelab AC Current Transformer (CT) Connection Instructions for HOBO Data Loggers
Detailed instructions for connecting Magnelab AC Current Transformers (CTs) to HOBO H22 and U30 Series Data Loggers using the FlexSmart TRMS Module. Includes safety warnings, required components, wiring diagrams, and HOBOware Pro software configuration values.
Preview TREE SCT Series Small Counting Scale: Operating Manual
This operating manual provides detailed instructions for the TREE SCT Series Small Counting Scales, covering setup, operation, features, calibration, maintenance, and troubleshooting for models SCT 600, SCT 1200, SCT 7, SCT 16, and SCT 33.
Preview Linortek iTrixx-Ultra 300 Ethernet Hour Meter: Quick Setup Guide
This guide provides quick setup instructions for the Linortek iTrixx-Ultra 300 Ethernet Hour Meter, covering installation, configuration, triggering methods, network setup, and monitoring.
Preview Rice Lake SCT-4X Series Operation Manual: Installation, Configuration, and Use
This operation manual provides detailed instructions for the installation, configuration, operation, and maintenance of the Rice Lake SCT-4X Series digital weight transmitter. It covers wiring diagrams, display functions, calibration procedures, communication protocols, and troubleshooting.