1. Introduction

The FireAngel FA6813 Carbon Monoxide (CO) Detector is designed to provide early warning of dangerous carbon monoxide levels in your home. This device utilizes an advanced electrochemical sensor to accurately detect CO gas, which is colorless, odorless, and highly toxic. It is a crucial safety device for any household.

This model is designed to replace previous FireAngel CO-9B and CO-9X models, offering enhanced features and reliability. It is powered by 2 AA batteries, ensuring continuous operation even during power outages.

FireAngel FA6813 Carbon Monoxide Detector front view

Figure 1: Front view of the FireAngel FA6813 Carbon Monoxide Detector.

FireAngel FA6813 Carbon Monoxide Detector with packaging highlighting features

Figure 2: The FA6813 detector with its packaging, emphasizing its 10-year sensor life, 85 dB(A) alarm, and included AA batteries.

2. Important Safety Information

WARNING: This device detects carbon monoxide gas. It is not designed to detect smoke, fire, or other gases. Carbon monoxide is a silent killer; it is invisible, odorless, and potentially fatal.

In Case of a CO Alarm:

  1. Ventilate: Immediately open all doors and windows to air out the premises. Turn off all combustion appliances (e.g., furnaces, water heaters, gas stoves).
  2. Evacuate: Leave the building immediately. Ensure everyone, including pets, is out of the affected area.
  3. Call for Help: From a safe location outside the building, contact your gas supplier or emergency services. Do not re-enter the premises until it has been declared safe by a qualified professional.
  4. Do Not Reuse: Do not use any combustion appliances again until they have been inspected and verified safe by a qualified technician.
FireAngel FA6813 Carbon Monoxide Detector side view with safety information

Figure 3: Side view of the FA6813, emphasizing its role in domestic safety and the properties of carbon monoxide.

3. Package Contents

Please check the box to ensure all components are present:

  • FireAngel Carbon Monoxide Alarm (FA6813)
  • 2 x AA Batteries
  • User Manual

4. Setup and Installation

4.1 Battery Installation

The FA6813 detector operates on 2 AA batteries. These are included in the package. To install:

  1. Locate the battery compartment on the back of the unit.
  2. Open the compartment cover.
  3. Insert the 2 AA batteries, ensuring correct polarity (+ and -).
  4. Close the battery compartment cover securely.

4.2 Placement and Mounting

The FA6813 is designed for versatile placement, suitable for both home use and travel. It can be wall-mounted or placed freestanding on a flat surface.

  • Wall Mounting: The device comes with an integrated mounting bracket and screws. Choose a location according to local regulations and manufacturer guidelines (typically near combustion appliances but not directly above them, and at breathing height). Mark the screw positions, drill pilot holes, insert wall plugs if necessary, and secure the bracket. Slide the detector onto the bracket.
  • Freestanding: For portable use or temporary placement, the detector can stand on its own. Place it on a stable, flat surface where it will not be easily knocked over.
FireAngel FA6813 Carbon Monoxide Detector in a travel setting

Figure 4: The FA6813 detector shown in a travel context, highlighting its portability and integrated mounting support for optional wall installation.

5. Operating Instructions

5.1 Normal Operation

Once batteries are installed, the device will perform a self-test and then enter normal monitoring mode. A small LED indicator may flash periodically to confirm it is active and monitoring.

5.2 Test Button Functionality

The large test button on the front of the detector serves multiple purposes:

  • Safety Test: Press the test button briefly to verify the proper functioning of the detector. A loud, sharp audible signal and 4 flashes of the red LED will confirm the alarm is working correctly. Perform this test regularly (e.g., weekly or monthly).
  • Sound Level Adjustment (Sound Test): Hold the test button down to cycle through different sound levels for the test alarm, allowing you to choose a comfortable volume.

5.3 Alarm Indications

When dangerous levels of carbon monoxide are detected, the FA6813 will alert you with:

  • Audible Alarm: 4 loud beeps (85 dB(A) at 3 meters).
  • Visual Alarm: A flashing red "CO" LED indicator.

5.4 Low Battery Indication and Sleep Easy™ Function

When the batteries are low, the device will indicate this with:

  • Visual Indication: A flashing orange "!" LED symbol.
  • Audible Indication: An audible beep.

To temporarily silence the low battery alert for 8 hours, press the test button. This activates the Sleep Easy™ mode, allowing you to silence the low battery beep, while the orange LED continues to flash as a reminder to replace the batteries.

FireAngel FA6813 Carbon Monoxide Detector with batteries and box

Figure 5: The FA6813 detector with its components, illustrating the advanced electrochemical sensor, Sleep Easy™ function, LED indicators, and sound amplification feature.

6. Maintenance

6.1 Battery Replacement

When the low battery indicator (flashing orange LED and beep) activates, it is time to replace the batteries. Follow the battery installation steps outlined in Section 4.1. Always use new, high-quality AA alkaline batteries.

6.2 Regular Testing

It is crucial to test your CO detector regularly, at least once a week or monthly, by pressing the test button. This ensures the alarm and its internal circuitry are functioning correctly.

6.3 Cleaning

Clean the exterior of the detector periodically with a soft, damp cloth. Do not use cleaning solvents or polishes, as these can damage the unit or interfere with the sensor's operation. Do not paint the unit.

7. Troubleshooting

ProblemPossible CauseSolution
Alarm sounds (4 beeps, red LED)Carbon monoxide detected.Follow the "In Case of a CO Alarm" procedure (Section 2). Do not ignore the alarm.
Orange LED flashes and unit beeps periodicallyLow battery warning.Replace both AA batteries immediately. Use the Sleep Easy™ function if needed to silence for 8 hours.
Test button does not activate alarmBatteries are dead or incorrectly installed; unit malfunction.Check battery installation and replace if necessary. If problem persists, the unit may need replacement.
Unit does not power onBatteries are dead or incorrectly installed.Ensure batteries are new and inserted with correct polarity.

8. Specifications

FeatureDetail
Model NumberFA6813-EUX10
ManufacturerFireAngel
Dimensions (L x W x H)12.3 x 7.3 x 3.55 cm (approx. 5 x 12.3 x 8 cm from other spec)
Weight141 Grams
ColorWhite
Power Source2 x AA Alkaline Batteries (included)
Sensor TypeElectrochemical
Alarm Loudness85 dB(A) at 3 meters
Operating Humidity25 to 95% relative humidity
Sensor Life10 years
FireAngel FA6813 Carbon Monoxide Detector with dimensions

Figure 6: The compact design of the FA6813, illustrating its dimensions and weight.

9. Warranty and Support

FireAngel is committed to providing high-quality safety products. For any questions, technical assistance, or warranty claims, please contact your supplier or refer to the FireAngel official website for support information.

Regular maintenance and adherence to the instructions in this manual will help ensure the longevity and proper functioning of your CO detector.

FireAngel brand image with a person looking up

Figure 7: FireAngel's commitment to protecting and improving lives through advanced and innovative technology.

Related Documents - FA6813-EUX10

Preview FireAngel FA6813 Carbon Monoxide Alarm User Manual
Comprehensive user manual for the FireAngel FA6813 Carbon Monoxide Alarm, covering installation, operation, maintenance, troubleshooting, and safety information.
Preview FireAngel FA6812/FA6813 Carbon Monoxide Alarm User Manual
User manual for the FireAngel FA6812 and FA6813 Carbon Monoxide (CO) alarms, providing installation, operation, safety, and maintenance instructions.
Preview FireAngel SCB10 Combination Smoke and Carbon Monoxide Alarm User Manual
User manual for the FireAngel SCB10, a combination smoke and carbon monoxide alarm, providing comprehensive instructions on installation, operation, maintenance, and safety for residential use.
Preview FireAngel CO-9X 7 Year Life Carbon Monoxide Detector User Manual
Comprehensive user manual for the FireAngel CO-9X 7 Year Life Carbon Monoxide Poisonous Gas Alarm. Learn about installation, operation, maintenance, safety, and troubleshooting.
Preview FireAngel Multisensor Plus User Manual: Smoke, Heat, CO Detector
Comprehensive user manual for the FireAngel Multisensor Plus and Multisensor Plus Kitchen, detailing installation, operation, safety, troubleshooting, and technical specifications for smoke, heat, and carbon monoxide detection.
Preview FireAngel CO Alarms FA3313, FA3322, FA3328, FA3820 User Manual
Comprehensive user manual for FireAngel Carbon Monoxide alarms (models FA3313, FA3322, FA3328, FA3820), covering positioning, installation, CO alarm awareness, maintenance, status indicators, sleep easy feature, LCD screen indicators, and technical specifications. Includes warranty and disposal information.