Adamson A9000

Adamson A9000 Silent 3-in-1 Mobile Air Conditioner User Manual

Model: A9000 | Brand: Adamson

1. Introduction

Thank you for choosing the Adamson A9000 Silent 3-in-1 Mobile Air Conditioner. This appliance is designed to provide efficient cooling, dehumidification, and air circulation for your indoor spaces. Please read this manual thoroughly before operation to ensure proper use, maintenance, and safety.

2. Safety Instructions

To reduce the risk of fire, electric shock, or injury when using your air conditioner, follow these basic precautions:

3. Product Overview

Familiarize yourself with the components of your Adamson A9000 unit.

Adamson A9000 Mobile Air Conditioner front view with cool air flowing out

Figure 3.1: Front view of the Adamson A9000 Mobile Air Conditioner, showing the air outlet and control panel.

Adamson A9000 Mobile Air Conditioner packaging label with specifications and energy rating

Figure 3.2: Packaging label for the Adamson A9000, displaying model information, weight, and energy efficiency class A.

Package Contents:

4. Setup and Installation

The Adamson A9000 is designed for easy installation. Follow these steps for optimal performance:

  1. Unpacking: Carefully remove the unit and all accessories from the packaging. Keep the unit upright as indicated on the packaging.
  2. Positioning: Place the air conditioner on a flat, stable surface. Ensure there is at least 20 cm (8 inches) of space around the unit for proper airflow.
  3. Exhaust Hose Installation:
    • Attach one end of the exhaust hose to the air outlet on the back of the unit.
    • Extend the hose to the nearest window.
  4. Window Seal Kit Installation (for sliding windows):
    • Open your sliding window (horizontally or vertically).
    • Install the window seal kit according to the instructions provided with the kit, ensuring a tight seal to prevent hot air from re-entering the room.
    • Insert the other end of the exhaust hose into the opening of the window seal kit.
  5. Power Connection: Plug the power cord into a grounded 2.3E+2 Volts (AC) electrical outlet.

Note: If you have casement windows, a specific KLIM AC window seal (available separately on Amazon) is recommended for proper installation.

5. Operating Instructions

The Adamson A9000 offers three primary operating modes: Cooling, Fan, and Dehumidifier.

5.1 Control Panel and Remote Control

The unit can be operated via the control panel on top of the unit or the included digital display remote control. The remote control allows for convenient operation from a distance.

5.2 Operating Modes

Cooling Mode

This mode provides powerful cooling for rooms up to 20 m² (80 m³).

  1. Press the Power button to turn on the unit.
  2. Press the Mode button until "Cool" or a snowflake icon is displayed.
  3. Use the Temperature Up/Down buttons to set your desired temperature. The unit can cool down to 16°C.
  4. Adjust the Fan Speed as needed.

Fan Mode

Circulates air without cooling, ideal for light breezes.

  1. Press the Mode button until "Fan" or a fan icon is displayed.
  2. Adjust the Fan Speed (Low, Medium, High) to your preference.

Dehumidifier Mode

Reduces excess moisture in the air, improving comfort and preventing mold growth.

  1. Press the Mode button until "Dry" or a water drop icon is displayed.
  2. The unit will automatically operate to remove moisture. No temperature setting is available in this mode.
  3. The A9000 features a self-evaporation function in cooling mode, reducing the need for manual draining. However, in high humidity conditions or extended dehumidifier mode use, you may need to drain accumulated water from the drainage port. Refer to the maintenance section for details.

Sleep Mode

For quiet operation during rest periods.

6. Maintenance

Regular maintenance ensures the longevity and efficient operation of your Adamson A9000.

6.1 Cleaning the Air Filter

The air filter should be cleaned every two weeks or more frequently depending on usage and air quality.

  1. Unplug the air conditioner from the power outlet.
  2. Locate and remove the air filter (usually at the back or side of the unit).
  3. Clean the filter with a vacuum cleaner or wash it gently with warm water and mild detergent.
  4. Rinse thoroughly and allow the filter to air dry completely before reinserting it into the unit.

6.2 Draining Water

While the unit has a self-evaporation function in cooling mode, manual draining may be necessary, especially in dehumidifier mode or high humidity environments.

  1. Turn off and unplug the unit.
  2. Place a shallow pan or tray under the drainage port (located at the bottom rear of the unit).
  3. Remove the drain plug. Water will begin to flow out.
  4. Once all water has drained, replace the drain plug securely.

6.3 Unit Cleaning and Storage

7. Troubleshooting

Before contacting customer support, please refer to the following troubleshooting guide:

ProblemPossible CauseSolution
Unit does not turn on.No power, power cord loose, circuit breaker tripped.Check power connection, ensure outlet is working, reset circuit breaker.
Unit not cooling effectively.Air filter dirty, exhaust hose blocked/disconnected, room too large, windows/doors open.Clean air filter, check exhaust hose connection, ensure room size is within limits, close windows/doors.
Unit is noisy.Unit not on a flat surface, fan speed too high.Place on a flat surface, select a lower fan speed or Sleep Mode. (Note: 65 dB is the specified noise level).
Water leakage.Drain plug loose, unit tilted, drainage pan full (if applicable).Ensure drain plug is secure, place unit on a level surface, drain water if necessary.

8. Specifications

FeatureDetail
BrandAdamson
ModelA9000
Functionality3-in-1 (Air Conditioner, Dehumidifier, Fan)
Cooling Power9000 BTU
Energy Efficiency ClassA
RefrigerantR290 (Natural Refrigerant Gas)
Noise Level65 dB
Voltage2.3E+2 Volts (AC)
Installation TypeWindow (with included kit)
Item Weight23 kg 900 g
Item Dimensions (LxWxH)70.2 x 32.5 x 29.5 Centimeters

9. Warranty and Support

The Adamson A9000 comes with a 5-year warranty, ensuring peace of mind regarding your purchase. For warranty claims, technical support, or any inquiries not covered in this manual, please contact Adamson customer service through the retailer where the product was purchased or visit the official Adamson website for contact information.

Please have your model number (A9000) and purchase details ready when contacting support.

Related Documents - A9000

Preview Adamson S10p Sub Compact Point Source User Manual
User manual for the Adamson S10p Sub Compact Point Source loudspeaker, covering safety, product introduction, wiring, amplification, presets, technical data, and accessories.
Preview Adamson Network Distribution System (NDS) User Manual
User manual for the Adamson Network Distribution System (NDS), detailing its features, specifications, and network redundancy for signal distribution to CS-Series loudspeakers and other audio equipment.
Preview Adamson S118 Ultra-Compact Subwoofer User Manual
Comprehensive user manual for the Adamson S118 Ultra-Compact Subwoofer, detailing its features, specifications, wiring, amplification, presets, and accessories. Includes safety guidelines and EU declarations.
Preview Adamson IS213 Ultra-Compact Subwoofer User Manual
Comprehensive user manual for the Adamson IS213 ultra-compact subwoofer, detailing product features, wiring, amplification, presets, weatherized options, and technical specifications. Includes safety warnings and EU Declaration of Conformity.
Preview Adamson S7 Ultra Compact Line Array User Manual
Comprehensive user manual for the Adamson S7 Ultra Compact Line Array loudspeaker, covering product introduction, wiring, amplification, presets, technical specifications, and accessories. Includes safety warnings and EU Declaration of Conformity.
Preview Adamson IS213 User Manual: Technical Specifications, Wiring, and Usage Guide
Comprehensive user manual for the Adamson IS213 ultra-compact subwoofer, detailing its technical specifications, wiring diagrams, amplification compatibility, preset configurations, weatherized features, and safety warnings. Includes product information and company contact details.