HOCANFLO HO-FLO750-1
HOCANFLO 750W Macerator Pump User Manual
Model: HO-FLO750-1
1. Introduction
This manual provides essential information for the safe and efficient installation, operation, and maintenance of your HOCANFLO 750W Macerator Pump. Please read all instructions carefully before installation and use. Retain this manual for future reference.
The HOCANFLO 750W Macerator Pump is designed for efficient wastewater management, capable of handling sewage, bathroom waste, and kitchen waste. It features a powerful 750W motor and versatile inlet/outlet options, making it suitable for various applications in basements, kitchens, and bathrooms.

Image 1.1: HOCANFLO 750W Macerator Pump with included accessories, including various pipes, clamps, and covers.
2. Safety Information
WARNING: Electrical shock hazard. Always disconnect power before servicing or installing the pump.
- Ensure the power supply matches the pump's voltage requirements (110-Volt).
- Do not operate the pump if the power cord is damaged.
- Keep hands and foreign objects clear of the pump's inlet and outlet during operation.
- This appliance is not intended for use by persons (including children) with reduced physical, sensory, or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety.
- Do not dispose of objects such as key chains, sanitary napkins, plastic bags, or sharp blades into the system, as this can cause blockages and damage the impeller.
3. Product Overview
The HOCANFLO 750W Macerator Pump is designed for efficient waste disposal in areas where traditional gravity drainage is not feasible. Key features include:
- Powerful 750W Motor: Equipped with a robust copper-wire motor for effective pulverization and waste removal.
- Low Noise Operation: Engineered for quieter performance.
- Versatile Inlets/Outlets: Features four inlet options and dual drainage outlets for flexible connection to multiple fixtures.
- Easy Maintenance: Designed with two repair covers for convenient access and troubleshooting.
- High Efficiency: Maximum flow rate of 190 L/Min and vertical lift up to 29.5ft.

Image 3.1: Illustration of the 750W copper wire motor, highlighting its power, strong crushing capability, 9m max lift, 190L/min max flow, and less than 39 dB(A) sound pressure level.
4. Setup and Installation
Proper installation is crucial for the optimal performance and longevity of your macerator pump. Follow these steps carefully:
4.1 Connecting Inlets and Outlets
The pump features four water inlets and two sewage outlets, allowing connection to various bathroom and kitchen fixtures.

Image 4.1: Diagram illustrating the four water inlets (for shower/sink, toilet, laundry room) and two sewage outlets, along with an activated carbon/vent pipe interface.

Image 4.2: Detailed view of the inlet and outlet ports on the macerator pump.
4.2 Piping Guidelines
Adhere to the following guidelines for proper piping to prevent backflow and ensure efficient drainage:

Image 4.3: Visual guide for correct piping, showing the sewage outlet pipe extended above the main sewage pipe to avoid backflow, and recommended pipe slopes.
- The pipe connecting to the sewage outlet should be extended and raised above the main sewage pipe to avoid backflow.
- All incoming pipes must have a slight downward slope (1/4" per foot) to ensure proper drainage when the pump is turned off.
- It is recommended to first install pipes vertically and then horizontally. Avoid using right-angle elbows whenever possible to ensure smooth flow.
4.3 Flexible Drainage Options
The pump offers flexible drainage configurations. If the top drainage pipe is blocked, sewage can be drained through the side drainage hole.

Image 4.4: Two options for drainage, demonstrating how the pump can be configured to drain sewage either through the top or side outlets, depending on installation requirements.
5. Operating Instructions
Once properly installed and connected to the power supply, the HOCANFLO 750W Macerator Pump operates automatically. It activates when wastewater enters the unit and reaches a predetermined level, then macerates and pumps the waste to the main drainage system.
- Ensure all connections are secure and leak-free before initial operation.
- Verify that the power supply is stable and matches the pump's requirements.
- The pump is designed for continuous use in appropriate applications.
6. Maintenance
Regular maintenance ensures the longevity and efficient operation of your macerator pump.
6.1 Routine Checks
- Periodically inspect all pipe connections for leaks.
- Ensure the pump area is clean and free from debris.
- Listen for unusual noises during operation, which may indicate a blockage or mechanical issue.
6.2 Access for Repair and Cleaning
The macerator pump is designed with two repair covers on the top for convenient access.

Image 6.1: Illustration of the two repair lids on the macerator pump. The right lid allows for motor replacement, while the left lid provides access to clear blockages without disassembling the entire pump.
To clear blockages or replace the motor:
- For Blockages: Open the maintenance panel on the left side of the top cover. If blocked, stir the blades and remove foreign objects without having to dismantle the entire water pump.
- For Motor Replacement: Open the repair cover on the right side of the top to access and replace the motor.

Image 6.2: View of the non-blocking blade design, which aids in preventing clogs.
7. Troubleshooting
If you encounter issues with your macerator pump, refer to the following common problems and solutions:

Image 7.1: Visual guide for troubleshooting, showing how to access the repair panel and clear debris from the impeller.
- Pump Not Activating or Blocked:
a. Disconnect power to the pump.
b. Open the repair panel on the top (left side).
c. Disconnect the connection between the pump and the toilet.
d. Use a screwdriver to rotate the impeller and remove any debris from the bottom impeller until the blade rotates smoothly. - Unusual Noises:
a. Check for foreign objects in the pump chamber (refer to blockage clearing steps).
b. Ensure the pump is securely mounted and not vibrating against other surfaces. - Leakage:
a. Inspect all pipe connections and tighten clamps if necessary.
b. Check seals and gaskets for damage and replace if worn.
If problems persist after following these steps, contact HOCANFLO customer support.
8. Specifications
| Feature | Specification |
|---|---|
| Brand | HOCANFLO |
| Model Number | HO-FLO750-1 |
| Power Source | Corded Electric |
| Voltage | 110 Volts |
| Wattage | 750 Watts |
| Maximum Flow Rate | 190 Liters Per Minute |
| Vertical Lift | 29.5 ft (approx. 9 meters) |
| Material | Polypropylene (PP), Stainless Steel |
| Product Dimensions | 19 x 14 x 7 inches |
| Item Weight | 20.9 pounds |
| Noise Level | <39 dB(A) |
9. Warranty and Support
The HOCANFLO 750W Macerator Pump typically comes with a 2-year warranty. Please refer to your purchase documentation for specific warranty terms and conditions.

Image 9.1: The macerator pump featuring activated carbon deodorization and ventilation duct deodorization for air freshness.
For technical support, warranty claims, or further assistance, please contact HOCANFLO customer service through the retailer where the product was purchased or visit the official HOCANFLO website.
Ask a question about this manual