Eujgoov PZEM-017

Eujgoov PZEM-017 DC Consumption Meter User Manual

Model: PZEM-017

1. Introduction

The Eujgoov PZEM-017 is a DC consumption meter designed for measuring DC voltage, current, active power, and energy consumption. It features an RS485 communication interface and supports the Modbus-RTU protocol, allowing for integration into various monitoring systems. This manual provides essential information for the proper installation, operation, and maintenance of your device.

Front view of the Eujgoov PZEM-017 DC Consumption Meter, a black rectangular device with green terminal blocks on each side.

Figure 1.1: Eujgoov PZEM-017 DC Consumption Meter. This image shows the front of the meter, highlighting its compact design and terminal connections.

2. Setup and Wiring

Proper wiring is crucial for the safe and accurate operation of the PZEM-017 meter. Refer to the wiring diagrams below for connection instructions.

Wiring diagram for PZEM-017 DC Consumption Meter showing connections for load, shunt, and RS485 to USB cable to PC.

Figure 2.1: Wiring Diagram for PZEM-017. This diagram illustrates how to connect the DC Consumption Meter to a load, a shunt (50A, 100A, 200A, or 300A), and an RS485 to USB cable for PC communication. Note the warning regarding independent power supply when input test voltage is less than 7V.

Connection Steps:

  1. Connect the load to the meter as indicated in the diagram.
  2. Connect the appropriate current shunt (50A, 100A, 200A, or 300A) to the meter's shunt terminals. The shunt is essential for current measurement.
  3. For communication, connect an RS485 to USB cable to the RS485 port on the meter and to your PC.
  4. Important Power Supply Note: If the input test voltage is less than 7V, an independent 5V power supply must be used via the USB port. Do not use a PC's USB port for this independent power supply if the input voltage is below 7V, as it may damage the PC.
Back view of the PZEM-017 DC Communication Module with wiring instructions and warnings.

Figure 2.2: Back Panel and Wiring Details. This image shows the back of the meter with terminal labels for shunt and RS485 port, along with a warning about using an independent 5V power supply when the input test voltage is less than 7V.

3. Operating Instructions

The PZEM-017 meter measures various DC electrical parameters. Once properly wired and powered, it can communicate data via its RS485 interface.

3.1 Data Measurement

The meter continuously measures and provides the following data:

  • Voltage: 0.05-300V DC
  • Current: 0.02-300A (depending on shunt used)
  • Active Power: 0.2-90kW
  • Energy Consumption: 0-9999kWh

3.2 Communication Protocol

The meter uses a UART to RS485 communication interface with a baud rate of 9600, 8 data bits, 2 stop bits, and no parity. The application layer utilizes the Modbus-RTU protocol, supporting function codes such as 0x03, 0x04, 0x06, 0x41, and 0x42.

For detailed register addresses and their resolutions, refer to the specifications section.

3.3 Alarm Functions

The device includes configurable over-voltage and low-voltage alarm thresholds. Default settings are 300V for high voltage and 7V for low voltage. These thresholds can be adjusted via the Modbus-RTU interface.

4. Maintenance

To ensure the longevity and accurate performance of your PZEM-017 meter, follow these general maintenance guidelines:

  • Keep the device clean and free from dust and moisture. Use a soft, dry cloth for cleaning.
  • Avoid exposing the meter to extreme temperatures or direct sunlight for extended periods. The recommended working temperature range is -20°C to 60°C.
  • Ensure all connections are secure and free from corrosion. Periodically check wiring for any signs of wear or damage.
  • Do not attempt to open the device casing, as this may void any applicable warranty and could expose you to electrical hazards.

5. Troubleshooting

If you encounter issues with your PZEM-017 meter, consider the following troubleshooting steps:

  • No Power/Display: Verify that the power supply is correctly connected and within the specified voltage range (0.05-300V). If the input test voltage is below 7V, ensure an independent 5V power supply is used via the USB port, as described in the Setup section.
  • Incorrect Readings: Check all wiring connections, especially to the shunt, for proper polarity and secure contact. Ensure the correct shunt rating is selected in your software configuration if applicable.
  • Communication Issues: Confirm the RS485 to USB cable is correctly connected. Verify the baud rate (9600), data bits (8), stop bits (2), and parity (none) settings in your communication software. Check the Modbus-RTU address.
  • Device Not Functioning: If the device does not work upon initial setup, double-check all connections and power sources. If issues persist, contact your retailer for support.

6. Specifications

Detailed technical specifications for the Eujgoov PZEM-017 DC Consumption Meter:

ParameterSpecificationResolution / Accuracy
ModelPZEM-017N/A
Voltage Measuring Range0.05-300V DC0.01V / 1%
Current Measuring Range0.02-300A (with appropriate shunt)0.01A / 1%
Power Measuring Range0.2-90kW0.1W / 1%
Energy Consumption Range0-9999kWh1Wh / 1%
Reset EnergyVia SoftwareN/A
Over Voltage Alarm Threshold (Default)300VConfigurable
Low Voltage Alarm Threshold (Default)7VConfigurable
Communication InterfaceRS485N/A
Baud Rate9600N/A
Data Bits8N/A
Stop Bits2N/A
ParityNoneN/A
Working Temperature-20°C to 60°CN/A
Product SizeApprox. 9 x 6 x 2.3 cmN/A
WeightApprox. 77g - 287g (depending on kit)N/A

6.1 Modbus Register Addresses (Read-Only)

Register AddressDescriptionResolution
0x0000Voltage value1 LSB = 0.01V
0x0001Current value1 LSB = 0.01A
0x0002Power value low 16 bits1 LSB = 0.1W
0x0003Power value high 16 bitsN/A
0x0004Energy value low 16 bits1 LSB = 1Wh
0x0005Energy value high 16 bitsN/A
0x0006High voltage alarm status0xFFFF = alarm, 0x0000 = no alarm
0x0007Low voltage alarm status0xFFFF = alarm, 0x0000 = no alarm

6.2 Modbus Register Addresses (Configurable)

Register AddressDescriptionResolution / Range
0x0000High voltage alarm threshold5-350V, 1 LSB = 0.01V (Default: 300V)
0x0001Low voltage alarm threshold1-350V, 1 LSB = 0.01V (Default: 7V)
0x0002Modbus-RTU address0x0001-0x00F7
0x0003Current range0x0000: 100A, 0x0001: 50A, 0x0002: 200A, 0x0003: 300A

7. Warranty and Support

7.1 Warranty Information

This product typically comes with a 10-day replacement policy from the date of purchase. For specific warranty terms, duration, and conditions, please refer to the documentation provided at the time of purchase or contact your retailer directly. Extended warranty options may be available from third-party providers.

7.2 Technical Support

For technical assistance, troubleshooting beyond the scope of this manual, or inquiries regarding product functionality, please contact the retailer or the manufacturer's authorized support channels. When contacting support, please have your product model (PZEM-017) and purchase details readily available.

© 2023 Eujgoov. All rights reserved. Information in this manual is subject to change without notice.