1. Product Overview
This manual provides essential information for the installation, operation, and maintenance of your EMKE 60x30 cm Double Layer Anthracite Hot Water Radiator. Please read these instructions carefully before installation and use to ensure safe and efficient operation.
The EMKE radiator is designed for central heating systems, offering efficient heat distribution and a modern aesthetic. It is constructed from high-quality SPCC steel, ensuring durability and excellent thermal conductivity.
Image: EMKE Panel Radiator in a living room, illustrating key features such as high-quality materials, seamless welding technology, high-quality protective coating, and high thermal conductivity.
Key Features:
- Dimensions: 60 cm (Height) x 30 cm (Width).
- Heat Output: 327 Watts.
- Number of Tubes: 4+4 (Double Layer).
- Material: High-quality SPCC steel, compliant with BS EN 442 and CE certified.
- Connection: Central connection, G1/2" thread, 50 mm connection size.
- Design: Flat panel, vertical wall-mounted design in Anthracite finish.
- High Thermal Conductivity: Efficiently heats air due to quality materials.
Image: Detailed view of the radiator's construction, highlighting the multi-layer protection: corrosion protection layer, low-carbon SPCC steel, and ecological powder coating.
Image: Illustration of the advanced lap welding technology used, which enhances welding strength and ensures a good seal.
Image: Detail showing the 1.5mm thick SPCC low-carbon steel, indicating its resistance to corrosion for a prolonged product lifespan.
2. Safety Information
Please observe the following safety precautions to prevent injury and damage to the product:
- Professional Installation: Installation should be carried out by a qualified professional in accordance with local building and plumbing regulations.
- Hot Surfaces: Radiator surfaces can become very hot during operation. Avoid prolonged contact to prevent burns. Supervise children and individuals with reduced physical, sensory, or mental capabilities.
- Pressure System: This is a pressurized hot water system. Do not attempt to open or modify the radiator while it is under pressure or hot.
- Leakage: Regularly inspect for any signs of leakage. If a leak is detected, immediately shut off the water supply to the radiator and contact a professional.
- Mounting: Ensure the wall mounting is secure and capable of supporting the radiator's weight when filled with water.
- Ventilation: Ensure proper ventilation during and after installation to prevent moisture buildup.
- Cleaning: Disconnect from the heating system and allow to cool completely before cleaning. Use only mild cleaning agents.
3. Setup and Installation
The EMKE hot water radiator is designed for wall mounting. A mounting kit is included. Please ensure you have the necessary tools and expertise for installation.
3.1. Unpacking and Inspection
- Carefully unpack the radiator and all components.
- Inspect for any damage during transit. Report any damage immediately to the supplier.
- Verify all parts listed in the packing list are present.
Image: Included accessories for installation, consisting of brackets, washers, long screws, screw dowels, and a rubber strip. The image also details the four-layer packaging for protection during transport.
3.2. Wall Mounting
- Choose Location: Select a suitable wall location, ensuring it can support the weight of the radiator when filled with water. Consider the distance from the wall (55 mm from interface to wall).
- Mark Drilling Points: Use the provided brackets as a template to mark the drilling points on the wall. Ensure the marks are level.
- Drill Holes: Drill holes of appropriate size and depth for the screw dowels.
- Insert Dowels: Insert the screw dowels into the drilled holes.
- Attach Brackets: Securely attach the mounting brackets to the wall using the long screws.
- Mount Radiator: Carefully lift the radiator and place it onto the installed brackets. Ensure it is securely seated.
3.3. Plumbing Connection
The radiator features a central connection with a G1/2" thread and a 50 mm connection size. Note: Valves are not included and must be purchased separately.
- Connect the radiator to your central heating system using appropriate G1/2" valves and fittings.
- Ensure all connections are tight and sealed to prevent leaks.
- Double-layer radiators can be mounted in both directions (flow and return can be swapped), while single-layer radiators have a fixed mounting direction.
Image: Various connection methods for the radiator, illustrating the G1/2" connection thread. A note clarifies that appropriate fittings and valves are available separately and are not included with the product.
4. Operating Instructions
Your EMKE radiator operates as part of a hot water central heating system. Once installed and connected, its operation is typically controlled by your home's central heating thermostat and boiler.
4.1. Initial Startup
- After installation, slowly fill the heating system with water, ensuring all air is bled from the radiator using the bleed valve (if present on your valve setup).
- Check all connections for leaks once the system is pressurized.
- Gradually increase the system temperature to allow the radiator to heat up.
4.2. Normal Operation
- The radiator will heat up when hot water from your central heating system circulates through it.
- The recommended inlet and outlet water temperatures are 75°C / 55°C for optimal performance.
- The wall-mounted design ensures efficient heat distribution and saves space.
Image: Radiator in a bathroom setting, demonstrating its high thermal conductivity and ability to quickly heat the surrounding air, providing sufficient warmth.
5. Maintenance
Regular maintenance ensures the longevity and efficiency of your EMKE radiator.
5.1. Cleaning
- Ensure the radiator is cool before cleaning.
- Wipe the surface with a soft, damp cloth.
- Do not use abrasive cleaners, solvents, or harsh chemicals, as these can damage the finish.
- For stubborn dirt, a mild soap solution can be used, followed by wiping with a clean, damp cloth.
5.2. Bleeding the Radiator
- If the radiator is not heating evenly (cold spots at the top), it may contain trapped air.
- Turn off your central heating system and wait for the radiator to cool down.
- Use a radiator key to slowly open the bleed valve (usually located at the top corner of the radiator).
- Hold a cloth or container under the valve to catch any water.
- Air will hiss out. Once water starts to come out steadily, close the valve.
- Check the system pressure and top it up if necessary after bleeding.
5.3. Annual Checks
- Have your central heating system, including radiators, checked annually by a qualified heating engineer.
- Ensure system pressure is maintained within the recommended range.
6. Troubleshooting
This section addresses common issues you might encounter with your radiator.
| Problem | Possible Cause | Solution |
|---|---|---|
| Radiator cold at the top, warm at the bottom. | Trapped air in the system. | Bleed the radiator (see Section 5.2). |
| Entire radiator is cold. |
|
|
| Radiator making gurgling noises. | Trapped air. | Bleed the radiator (see Section 5.2). |
| Water leaking from connections. | Loose connections or faulty seals. | Immediately shut off water supply. Tighten connections or replace seals. Contact a professional if unsure. |
If you are unable to resolve an issue, please contact a qualified heating engineer or EMKE customer support.
7. Specifications
Detailed technical specifications for your EMKE Hot Water Radiator.
Image: Panel Radiator Specifications table, detailing operation mode (Hot Water Circulation), installation type (Wall Mounted), connection thread (G1/2"), connection size (50mm), wall distance (86mm to outer edge heating body), and recommended inlet/outlet water temperatures (75°C / 55°C). It also shows examples of suitable locations like bathrooms, living rooms, and bedrooms.
| Specification | Value |
|---|---|
| Brand | EMKE |
| Model | 60x30cm Double layer |
| Color | Anthracite |
| Dimensions (H x W) | 60 x 30 cm |
| Heat Output | 327 W |
| Number of Tubes | 4+4 |
| Application Area | 4.4 m² |
| Layers | Double layer |
| Weight | 25 kg |
| Connection Type | Central Connection |
| Connection Thread | G1/2" |
| Connection Size | 50 mm |
| Distance from Wall | 55 mm (interface to wall) |
| Material | SPCC Steel |
| Certifications | BS EN 442, CE certified |
| Recommended Inlet/Outlet Water Temperature | 75°C / 55°C |
| Power Source | Hot Water Central Heating |
| Mounting Type | Wall Mount |
| Recommended Use | Indoor heating for bathrooms, living rooms, bedrooms, etc. |
8. Warranty and Support
EMKE products are manufactured to high standards and come with a standard warranty. Please refer to your purchase documentation for specific warranty terms and conditions.
For technical support, spare parts, or warranty claims, please contact EMKE customer service through the retailer where you purchased the product or visit the official EMKE website.
Note: Valves are not included with the radiator. Information on spare parts availability is currently unavailable.