sinocare SafeAQSmart10
SINOCARE SAFE AQ SMART Blood Glucose Monitor User Manual
Model: SafeAQSmart10 | Brand: sinocare
1. Product Overview
The SINOCARE SAFE AQ SMART Blood Glucose Monitor is designed for fast, accurate, and reliable measurement of blood sugar/diabetes levels. This device utilizes code-free test strips and requires only a small blood sample, providing results in a short time.

Image: Complete SINOCARE SAFE AQ SMART Blood Glucose Monitor kit, including the meter, test strips, lancets, and lancing device.
2. What's in the Box
Your SINOCARE SAFE AQ SMART kit includes the following components:
- Glucometer Device
- Test Strips (quantity as per pack)
- Lancets (quantity as per pack)
- Lancet Device

Image: Individual components of the blood glucose monitoring kit, including the meter, test strips, lancets, and lancing device.
3. Device Components and Display
Familiarize yourself with the parts of your blood glucose monitor and test strip:

Image: Detailed diagram illustrating the various parts of the Safe AQ Smart meter (test strip slot, Sannuo logo, date & time, test value, unit value, power button, battery case) and the test strip (blood sample collection end, inserting end).
4. Setup and First Use
4.1. Battery Installation
The Safe AQ Smart monitor requires batteries (not included). Open the battery case at the back of the device and insert the required batteries, ensuring correct polarity. Close the battery case securely.
4.2. Preparing the Lancing Device
- Unscrew the cap of the lancing device.
- Insert a new sterile lancet firmly into the lancet holder.
- Twist off the protective cap of the lancet.
- Replace the lancing device cap.
- Adjust the penetration depth by rotating the cap (9 different settings available for comfort).
- Pull back the cocking control until it clicks, indicating it is ready for use.
5. Operating Instructions: Taking a Blood Glucose Reading
Follow these steps for an accurate blood glucose measurement:
- Prepare: Wash your hands thoroughly with soap and warm water. Dry them completely.
- Insert Test Strip: Insert a new test strip into the test strip slot of the meter with the black blocks facing up. The meter will automatically turn on. No coding is required.
- Obtain Blood Sample: Puncture the side of your fingertip with the prepared lancing device. Gently squeeze your finger to form a small drop of blood.
- Apply Blood Sample: Touch the tip of the test strip to the blood drop. The strip will draw the blood into the reaction area. Only 0.6µL of blood is needed.
- Read Result: The meter will display your blood glucose reading in approximately 5 seconds.

Image: Visual step-by-step guide showing how to insert a test strip, puncture a finger with the lancing device, apply a blood sample to the strip, and view the result on the meter.
Important Note: The delicate FAD-GDH test strips have strong resistance to multi-material interference, ensuring high accuracy.
6. Maintenance and Storage
6.1. Cleaning the Meter
Wipe the meter's exterior with a soft, damp cloth. Do not immerse the meter in water or use harsh cleaning agents. Ensure no liquid enters the test strip slot.
6.2. Test Strip Storage
Store test strips in their original vial with the cap tightly closed. Keep them in a cool, dry place away from direct sunlight and heat. Test strips have a storage period of up to 24 months, but should be used within 6 months after the vial is opened.
6.3. Disposal of Used Materials
Dispose of used test strips and lancets in a proper sharps container or according to local regulations for biohazardous waste.
7. Troubleshooting
If you encounter issues with your SINOCARE SAFE AQ SMART monitor, refer to the following common problems and solutions:
| Problem | Possible Cause | Solution |
|---|---|---|
| Meter does not turn on | Dead or incorrectly installed batteries | Replace batteries or ensure they are installed correctly. |
| Inaccurate readings | Expired test strips, improper blood sample application, dirty meter, or environmental factors. | Check strip expiry date. Ensure sufficient blood sample. Clean meter. Perform a control solution test if available. Consult a healthcare professional if readings remain inconsistent. |
| Error message on display | Refer to the specific error code in the full manual (if available) or contact customer support. | Turn off the meter, remove the strip, and restart the process. If the error persists, contact customer support. |
| Blood sample not drawn into strip | Insufficient blood sample or incorrect application. | Ensure a sufficient blood drop is formed. Touch the tip of the strip to the blood drop, not the skin. Use a new strip. |
8. Specifications
Key technical specifications for the SINOCARE SAFE AQ SMART Blood Glucose Monitor:
- Brand: sinocare
- Model Number: SafeAQSmart10
- Measurement Time: Approximately 5 seconds
- Blood Sample Volume: 0.6µL
- Coding: No coding required
- Test Strip Type: FAD-GDH Test Strip
- Memory: 1 (Number of Memory Sticks, likely means 1 device)
- Item Weight: 200 g
- Product Dimensions: 18.5 x 6 x 16.5 cm
- Manufacturer: Changsha Sinocare Inc.
- Accuracy: High accuracy, anti-interference (error range within +-15%)

Image: Diagram highlighting technical improvements such as dedicated FAD-GDH test strip, upgraded chip, upgraded needle, no coding, and compliance with national standards (ISO15197~2013).

Image: Close-up of the dedicated FAD-GDH Test Strip, emphasizing its strong resistance to multi-material interference and suitability for a wider range of people.
9. Warranty and Support
For product support, inquiries, or warranty information, please contact Sinocare customer service. While specific warranty details are not provided here, Sinocare is committed to product quality and customer satisfaction.
You can visit the official Sinocare store for more information and contact details: Sinocare Official Store
Ask a question about this manual