1. Safety Information
Please read and understand all safety information before using the REVASRI Laser Distance Meter KL02. Failure to follow these instructions may result in laser radiation exposure, electric shock, fire, or serious injury.
1.1 Laser Safety
- CAUTION: This device emits a Class 2 laser. Do not stare directly into the laser beam.
- Avoid direct eye exposure to the laser beam.
- Do not point the laser beam at people or animals.
- Do not disassemble the device. Repairs should only be performed by authorized service personnel.
1.2 General Safety
- Keep the device out of reach of children.
- Do not use the device in explosive atmospheres or near flammable materials.
- Protect the device from moisture and direct sunlight.
- Use only the specified charging cable and power adapter.
2. Product Overview
The REVASRI KL02 is a professional laser distance meter designed for accurate and efficient measurements. Its compact and lightweight design makes it easy to carry and use in various environments.
2.1 Device Components

- Screen: Displays measurement data, battery status, and mode indicators.
- Measurement Button (Red Triangle): Initiates single measurements.
- Unit Button: Switches between measurement units (m/in/ft).
- +/- Button: For addition and subtraction measurements.
- FUNC Button: Selects different measurement modes (Area, Volume, Pythagorean, Continuous).
- Front/Rear Reference Button: Changes the measurement reference point.
- Power/Backlight Button: Turns the device on/off and controls screen backlight.
- History/Preset Button: Accesses stored data or sets preset values.
2.2 Electronic Bubble Level

The integrated electronic bubble level provides real-time horizontal and vertical angle updates, ensuring more accurate measurements, especially for leveling tasks.
3. Setup
3.1 Charging the Device

The REVASRI KL02 features a built-in rechargeable lithium battery. To charge, connect the provided USB-C cable to the device's charging port and a suitable USB power source. The battery indicator on the screen will show the charging status.
3.2 Power On/Off
- To Power On: Press the Power/Backlight button once.
- To Power Off: Press and hold the Power/Backlight button for a few seconds. The device will also automatically power off after a period of inactivity to save battery.
4. Operation
The REVASRI KL02 offers multiple measurement modes to suit various applications. Use the FUNC button to cycle through the modes.
4.1 Basic Distance Measurement
- Ensure the device is in single distance measurement mode (default or select via FUNC).
- Point the laser at the target surface.
- Press the Measurement button once. The measured distance will appear on the screen.
4.2 Continuous Measurement (Min/Max)
- From single distance mode, press and hold the Measurement button for 1 second to enter continuous measurement.
- Move the device slowly. The screen will display real-time maximum, minimum, and current distances.
- Press the Measurement button again to stop.
4.3 Area Measurement

- Press FUNC until the area icon appears.
- Measure the first side (length) by pressing the Measurement button.
- Measure the second side (width) by pressing the Measurement button again.
- The device will automatically calculate and display the area.
4.4 Volume Measurement

- Press FUNC until the volume icon appears.
- Measure length, width, and height sequentially by pressing the Measurement button for each dimension.
- The device will automatically calculate and display the volume.
4.5 Pythagorean Measurement (Indirect Measurement)

The Pythagorean mode allows for indirect measurement of heights or distances when direct measurement is not possible.
- Press FUNC until the desired Pythagorean icon appears (e.g., 2-point or 3-point).
- Follow the on-screen prompts to take the required measurements (e.g., hypotenuse, base).
- The device will calculate and display the unknown dimension.
4.6 Addition and Subtraction
- Perform a measurement.
- Press the +/- button to select addition or subtraction.
- Perform the next measurement. The result will be added to or subtracted from the previous measurement.
4.7 Unit Switching
- Press the Unit button to cycle through available units: meters (m), inches (in), and feet (ft).
4.8 Stakeout Function

The stakeout function allows you to set a predetermined target value. For example, to cut a piece of wood to 1 meter, set the target value to 1m. The device will guide you to the precise point.
5. Data Storage

The REVASRI KL02 can store up to 28 groups of measurement data. To access stored data, press the History/Preset button. Use the arrow buttons (if available, or repeat pressing the history button) to navigate through the stored measurements.
6. Specifications
| Feature | Specification |
|---|---|
| Model Number | KL02 |
| Measurement Accuracy | ±2 mm |
| Measurement Time | 0.25 seconds |
| Units | m / in / ft |
| Data Storage | 28 groups |
| Battery Type | Lithium-ion (250mAh) |
| Charging Port | USB Type-C |
| Measurements per Charge | Approx. 3000 single measurements |
| Electronic Bubble Level | Yes (real-time angle updates) |
| Dimensions | 8.5 x 8.5 x 8.5 cm |
| Weight | 39 g |
| Material | Aluminum-magnesium alloy |
| Water Resistance | IP54 (Water-resistant) |
7. Troubleshooting
If you encounter issues with your REVASRI KL02, refer to the following common problems and solutions:
- Problem: Cannot obtain a reading.
Solution: The minimum range is typically 0.05m. Ensure the distance is within the allowed range. Avoid measuring through glass or in very small rooms. Strong light, rain, fog, or heavy dust can also affect laser transmission and measurement accuracy. - Problem: Measurement accuracy seems inconsistent.
Solution: Environmental factors such as strong sunlight, fog, rain, or dust can interfere with the laser. Ensure the target surface is clear and the environment is suitable for laser measurement. - Problem: Device does not turn on.
Solution: Check the battery level. If the battery is low or depleted, charge the device using the provided USB-C cable.
8. Maintenance
- Cleaning: Use a soft, damp cloth to clean the device. Do not use abrasive cleaners or solvents.
- Storage: Store the device in a cool, dry place when not in use. Avoid extreme temperatures.
- Battery Care: For optimal battery life, avoid fully discharging the battery frequently. Charge the device regularly, even if not in constant use.
9. Warranty and Support
The REVASRI KL02 Laser Distance Meter comes with a 1-year product warranty from the date of purchase.
For technical support, warranty claims, or any questions regarding your device, please contact REVASRI customer service through the platform where you purchased the product or visit the official REVASRI website for contact information.