1. Introduction
The Viconor Red Light Therapy Lamp is designed to provide targeted light therapy using a combination of 660nm red light and 850nm infrared light. This device is intended for personal use to support skin health, muscle recovery, and joint comfort. Its curved design and adjustable stand allow for versatile application across various body areas.
2. Important Safety Information
- Eye Protection: Always wear the provided protective goggles during operation to shield your eyes from direct light exposure.
- Medical Conditions: Consult a healthcare professional before using this device if you have any pre-existing medical conditions, are pregnant, or are taking photosensitive medications.
- Skin Sensitivity: Do not use on broken, irritated, or infected skin. Discontinue use if you experience discomfort or adverse reactions.
- Children and Pets: Keep the device out of reach of children and pets.
- Electrical Safety: Ensure the power cord is not damaged and is properly connected. Unplug the device when not in use or before cleaning. Do not operate with wet hands.
- Ventilation: Ensure adequate ventilation around the device during use.
3. Package Contents
Please verify that all components are present in the package:
- Viconor Red Light Therapy Lamp Panel
- Adjustable Stand Assembly (base, pole, adjustable arm)
- Power Cord
- Hook (for hanging option)
- Protective Goggles
4. Setup Instructions
Follow these steps to assemble your Viconor Red Light Therapy Lamp:
- Assemble the Stand: Connect the pole sections to the heavy base. Ensure all connections are secure.
- Attach the Adjustable Arm: Secure the adjustable arm to the top of the stand pole.
- Mount the Lamp Panel: Attach the red light therapy panel to the adjustable arm. The arm allows for 180-degree swivel and angle adjustments. After adjusting the angle, tighten the screws carefully to avoid thread damage.
- Positioning: Place the assembled unit on a stable, flat surface. Ensure the arm and base are aligned in the same direction (forward) for optimal stability. If positioning towards the side or back, place heavy objects on the base to increase stability.
- Power Connection: Plug the power cord into the device and then into a standard electrical outlet.

Figure 4.1: Installation in Three Steps

Figure 4.2: Flexibility with Adjustable Arm Angle
Video 4.1: Official Viconor video demonstrating the setup and use of the Red Light Therapy Lamp for face and body.
5. Operating Instructions
To use your Viconor Red Light Therapy Lamp:
- Wear Goggles: Always put on the protective goggles before turning on the device.
- Power On: Use the remote control to turn on the device.
- Select Mode: Choose your desired light mode: 660nm Red Light, 850nm Infrared Light, or both combined.
- Set Timer: Adjust the session duration using the remote control. Recommended session times are typically 15-30 minutes per area.
- Positioning: Position the lamp approximately 6 to 18 inches away from the target area of your body or face. The intensity of the light decreases with distance.
- Session Frequency: For best results, use the device daily or as recommended by a healthcare professional.

Figure 5.1: User applying red light therapy to the face.

Figure 5.2: User relaxing during a red light therapy session.

Figure 5.3: Light intensity at various distances.
6. Maintenance
Proper maintenance ensures the longevity and optimal performance of your device:
- Cleaning: Always unplug the device before cleaning. Use a soft, dry cloth to wipe the lamp panel and stand. Do not use abrasive cleaners or immerse the device in water.
- Storage: Store the device in a cool, dry place away from direct sunlight and moisture when not in use.
- Inspection: Periodically inspect the power cord and connections for any signs of damage. If damage is found, discontinue use and contact customer support.
7. Troubleshooting
If you encounter any issues with your Viconor Red Light Therapy Lamp, please refer to the following common solutions:
- Device Not Turning On:
- Ensure the power cord is securely plugged into both the device and a working electrical outlet.
- Check if the power outlet is functional by plugging in another appliance.
- Verify that the remote control batteries are not depleted.
- Lights Not Emitting:
- Confirm the device is powered on and the correct light mode is selected.
- Note that 850nm infrared light is invisible to the naked eye, so you will not see it illuminate.
- Unstable Stand:
- Ensure all stand connections are tightened.
- Verify the arm and base are aligned forward. If not, place a heavy object on the base for added stability.
If these steps do not resolve the issue, please contact Viconor customer service for further assistance.
8. Specifications
| Feature | Detail |
|---|---|
| Model Number | Viconor |
| Product Dimensions | 0.39 x 0.39 x 0.39 inches |
| Weight | 7.23 Pounds |
| Light Source Type | LED (Red Light & Infrared) |
| Wavelengths | 660nm (Red Light), 850nm (Infrared Light) |
| Number of LEDs | 120 |
| Wattage | 30 watts |
| Control Method | Remote |
| Power Source | Corded Electric |
| Mounting Type | Floor Mount |
| Indoor/Outdoor Usage | Indoor |
| Water Resistance Level | Not Water Resistant |
9. Warranty and Support
Viconor is committed to providing quality products and customer satisfaction. If you have any questions, concerns, or require assistance with your Red Light Therapy Lamp, our customer service team is available 24 hours a day to help you.
Please refer to your purchase documentation for specific warranty details. For direct support, you may visit the official Viconor store or contact us through the platform where you purchased the device.
Viconor Store: Viconor Official Store