Bell+Howell Vacutrim
Bell+Howell Vacutrim Cordless Body Shaver User Manual
Model: Vacutrim
Introduction
The Bell+Howell Vacutrim is a cordless, rechargeable body shaver designed for men, featuring an integrated vacuum system to collect hair clippings. It offers 20 precise trim length settings for versatile grooming.

Image: The Bell+Howell Vacutrim Cordless Body Shaver shown alongside its retail packaging, highlighting its key features.
Safety Information
For your safety and to ensure proper operation, please adhere to the following guidelines:
- Avoid touching the blades directly to prevent injury.
- Refer to the complete product manual for specific safety instructions, including details on water resistance capabilities.
- Keep the device out of reach of children.
- Do not use the device if it is damaged or malfunctioning.
- Ensure the charging cable and adapter are in good condition before use.
Package Contents
The Bell+Howell Vacutrim package includes the following components:
- Bell+Howell Vacutrim Cordless Body Shaver
- Charging cable (USB)
- Home adapter for electrical socket charging
- Cleaning brush
- Lubricating oil
- 2 comb attachments
- User manual (this document)

Image: All components included with the Bell+Howell Vacutrim: the shaver, two comb attachments, a cleaning brush, blade oil, and a USB charging cable.
Setup
Charging the Device
Before initial use, fully charge the Bell+Howell Vacutrim. The device can be charged using the provided USB cable and home adapter.
- Connect the USB charging cable to the Vacutrim.
- Plug the USB cable into the home adapter, then into an electrical socket, or directly into any compatible USB port (e.g., laptop).
- The initial charge time is approximately 2.5 hours (150 minutes).
- A full charge provides approximately 90 minutes of run time.
- The Vacutrim can be used while it is plugged in and charging.

Image: The Bell+Howell Vacutrim can be charged via USB, connecting to a laptop or a wall adapter, with details on charge and run times.
Operating Instructions
Selecting Trim Length
The Vacutrim features a calibration dial with 20 trim length settings, eliminating the need for multiple comb attachments. Simply turn the dial to select your desired length.

Image: A close-up view of the Vacutrim's calibration dial, which allows for easy adjustment of the trim length without changing comb attachments.
Trimming Procedure
Follow these steps for effective grooming:
- Ensure the device is fully charged or plugged in.
- Select the desired trim length using the calibration dial.
- Turn on the device.
- Trim in an upward and downward motion, moving against the direction of hair growth for best results.
- The integrated vacuum system will collect hair clippings during use.

Image: A man demonstrating the use of the Bell+Howell Vacutrim for body grooming, highlighting its versatility for various body areas.
Maintenance
Emptying Hair Clippings
The built-in vacuum system collects hair clippings in an internal chamber. Empty this chamber after each use or as needed to maintain optimal performance.
- To access the compartment, push up on the top section of the shaver.
- Discard the accumulated hair clippings.
- Close the compartment securely after emptying.

Image: Visual guide demonstrating how to open the Vacutrim's compartment to empty collected hair clippings.
Cleaning and Lubrication
Regular cleaning and lubrication ensure the longevity and performance of your Vacutrim.
- Use the provided cleaning brush to remove any remaining hair from the blades and internal components.
- Apply a few drops of the lubricating oil to the blades after cleaning to maintain smooth operation.
- The ceramic blade is washable; rinse with water for easy cleanup. Ensure the device is off and unplugged before rinsing.

Image: A detailed view of the Vacutrim's ceramic blade, designed for durability, longevity, precision, and safety.
Troubleshooting
If you encounter issues with your Bell+Howell Vacutrim, refer to the following common solutions:
| Problem | Possible Cause | Solution |
|---|---|---|
| Device does not turn on or charge. | Battery is depleted; charging cable or adapter is faulty; device malfunction. | Ensure the device is fully charged (2.5 hours for initial charge). Check if the charging cable and adapter are securely connected and functional. Try charging from a different USB port or outlet. If the issue persists, contact customer support. |
| Poor trimming performance or pulling hair. | Blades are dull or clogged with hair; insufficient lubrication. | Clean the blades thoroughly with the provided brush. Apply lubricating oil to the blades. Ensure the hair collection chamber is not full. |
| Vacuum system not collecting hair effectively. | Hair collection chamber is full; vacuum intake is blocked. | Empty the hair collection chamber. Check for any blockages in the vacuum intake area and clear them. |
Specifications
| Feature | Detail |
|---|---|
| Model Name | Vacutrim |
| Dimensions | 7.5 inches (length) |
| Weight | 1.01 Pounds |
| Power Source | Battery Powered (Rechargeable Lithium-Ion) |
| Initial Charge Time | 2.5 hours (150 minutes) |
| Run Time | 90 minutes (after full charge) |
| Trim Settings | 20 precise length settings via calibration dial |
| Blade Material | Stainless Steel / Ceramic Blade |
| Color | Black |
| Integrated Feature | Vacuum System for hair collection |
Warranty and Support
For warranty information and customer support, please refer to the documentation included with your product or contact Bell+Howell customer service directly. Keep your proof of purchase for any warranty claims.
Manufacturer: Emson
Ask a question about this manual
Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.