1. Introduction
This manual provides essential information for the safe and efficient operation, installation, and maintenance of your SBONNI 100mm Bathroom Extractor Fan. Please read this manual thoroughly before installation and use, and retain it for future reference.
The SBONNI 100mm Extractor Fan is designed to improve air quality by removing humidity, odors, and stale air from various indoor environments such as bathrooms, kitchens, utility rooms, garages, and attics. It features a 12W motor, a powerful 130m³/h airflow, and operates quietly at 34 dB. Equipped with a 1.5-meter power cable and an integrated on/off switch, it offers convenient and immediate control.
2. Safety Information
WARNING: Electrical Shock Hazard
- Always disconnect power at the main circuit breaker before installing, servicing, or cleaning the unit. Failure to do so can result in serious injury or death.
- Installation must be performed by a qualified electrician and in accordance with all local and national electrical codes.
- Do not install this fan in areas where it may be directly exposed to water spray or submersion.
- Ensure the power supply voltage matches the specifications of the fan (230V).
- Do not operate the fan with a damaged cord or plug. If the cord is damaged, it must be replaced by the manufacturer, its service agent, or similarly qualified persons to avoid a hazard.
- This appliance is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety.
3. Product Overview
The SBONNI 100mm Extractor Fan is designed for efficient and quiet operation. Key components include the cover, central panel, base, motor, and fan blades.

Figure 3.1: Exploded view of the SBONNI Extractor Fan, highlighting its main components and performance metrics.
The fan features a ball-bearing motor for extended lifespan (over 30,000 hours) and reduced heat generation. Its seven precisely balanced blades ensure stable operation and minimize noise. The casing is constructed from durable PC+ABS material, offering resistance to corrosion and wear.
4. Specifications
| Feature | Specification |
|---|---|
| Brand | SBONNI |
| Model | SBONNI-100-EX |
| Color | White |
| Diameter | 100 mm |
| Wattage | 12 watts |
| Voltage | 230 Volts |
| Noise Level | 34 dB |
| Special Features | Integrated On/Off Switch |
| Item Weight | 480 g |
| Power Source | Corded Electric |
| Product Dimensions | 15.5P x 15.5L x 12.5H cm |
| Recommended Use | Air Circulation |

Figure 4.1: Product dimensions of the SBONNI 100mm Extractor Fan.
5. Setup and Installation
Before beginning installation, ensure you have all necessary tools and materials. Always disconnect power at the main circuit breaker.
5.1. Package Contents
Verify that all items are present in the package:

Figure 5.1: Packaging contents.
- SBONNI 100mm Extractor Fan Unit
- Instruction Manual
- Mounting Screws and Wall Plugs
- Adhesive Pads (for certain installation types)
5.2. Wall Installation
There are two methods for wall installation: with adhesive or with screws.
Method A: Installation with Silicone Adhesive
- Drill a 100mm diameter hole in the wall at the desired location.
- Insert the fan unit into the hole and secure it with silicone adhesive around the edges for a firm seal.

Figure 5.2: Wall installation using silicone adhesive.
Method B: Installation with Screws
- Gently loosen the screws on the fan's front panel to remove it.
- Mark the screw positions on the wall using the fan's base as a template.
- Drill holes at the marked positions and insert plastic wall plugs.
- Secure the fan base to the wall with screws. Reattach the front panel and tighten its screws to complete the installation.

Figure 5.3: Wall installation using screws.
5.3. Window Installation
- Cut a 100mm diameter hole in the glass window.
- Position the gasket around the edge of the hole in the glass.
- Insert the fan unit into the opening. For a secure installation, it is recommended to use glass adhesive.

Figure 5.4: Window installation steps.
5.4. Ceiling Installation
- If your ceiling is made of thin aluminum or plasterboard panels and cannot support the unit's weight, we recommend adding wooden reinforcement.
- Drill a 100mm diameter installation hole in the ceiling.
- Use screws to firmly attach the unit to the ceiling.
- Connect to the flexible duct with a clamp in the lower part and cover it with the panel to complete the installation.

Figure 5.5: Ceiling installation steps.
6. Operating Instructions
The SBONNI 100mm Extractor Fan is equipped with a simple on/off switch for ease of use.

Figure 6.1: Extractor fan with integrated on/off switch.
- Ensure the fan is correctly installed and securely plugged into a 230V power outlet.
- Locate the in-line on/off switch on the power cable.
- To turn the fan ON, slide the switch to the 'I' position.
- To turn the fan OFF, slide the switch to the 'O' position.
The fan will begin to extract air immediately upon activation. Its quiet operation ensures minimal disturbance.
7. Maintenance
Regular cleaning and maintenance will ensure optimal performance and longevity of your extractor fan.
7.1. Cleaning the Fan
- Disconnect Power: Always turn off the fan and unplug it from the power outlet before cleaning.
- Remove Front Panel: Gently loosen the screws on the front panel and remove it.
- Clean Surfaces: Use a soft, damp cloth with a mild detergent to wipe down the exterior surfaces and the inside of the front panel. Avoid abrasive cleaners or solvents.
- Clean Fan Blades: Carefully clean the fan blades with a soft brush or cloth to remove dust and debris. Do not bend the blades.
- Dry Thoroughly: Ensure all parts are completely dry before reassembling.
- Reassemble: Reattach the front panel and tighten the screws.
Note: Do not immerse the fan unit in water. Do not spray water directly onto the motor or electrical components.
8. Troubleshooting
If you encounter any issues with your SBONNI Extractor Fan, refer to the following common problems and solutions:
| Problem | Possible Cause | Solution |
|---|---|---|
| Fan does not turn on | No power supply Switch is off Damaged power cable/plug | Check if the power outlet is working. Ensure the switch is in the 'ON' position. Inspect the cable and plug for damage. If damaged, contact support. |
| Low airflow | Blocked air vents Dirty fan blades | Check for obstructions in the intake or exhaust vents. Clean the fan blades as described in the Maintenance section. |
| Excessive noise or vibration | Loose mounting Debris in fan blades Damaged motor/bearings | Ensure the fan is securely mounted to the wall/ceiling/window. Clean the fan blades for any foreign objects. If noise persists, contact customer support. |
| Fan stops unexpectedly | Overheating protection activated | Disconnect power and allow the fan to cool down. Check for obstructions that might cause overheating. Reconnect power after 15-20 minutes. |
If the problem persists after attempting these solutions, please contact SBONNI customer support.
9. Warranty and Support
Your SBONNI Extractor Fan comes with a 24-month warranty from the date of purchase, covering manufacturing defects. Additionally, we offer a 30-day fast refund policy.
The product has obtained CE, RoHS, and LVD certifications, ensuring compliance with European quality and safety standards.

Figure 9.1: Product Certifications.
For any questions, technical assistance, or warranty claims, our customer service team is available 24/7. Please refer to your purchase documentation for contact details or visit the official SBONNI website.