RWRAPS TM612

RWRAPS TM612 Programmable Timer Switch User Manual

Model: TM612 | Brand: RWRAPS

1. Introduction

The RWRAPS TM612 is a high-accuracy, programmable 24-hour time clock designed for automatic control of various electrical equipment. Featuring a large display and two relay outputs, this timer switch allows for precise scheduling with up to 44 ON/OFF programs per day or week. Its robust design includes a long-life silicone button and a high-power relay, ensuring reliable operation for extended periods. The device also incorporates a clock correction function and a keyboard lock to prevent unintended adjustments.

This manual provides detailed instructions for the installation, operation, maintenance, and troubleshooting of your TM612 timer switch.

2. Key Features

  • High Accuracy: Time error less than 1 second per day, ensuring precise timing.
  • Programmable Schedules: Supports up to 44 ON/OFF programs daily or weekly for flexible control.
  • Dual Relay Outputs: Equipped with two independent relay outputs (2NO 2NC) for versatile applications.
  • Large Digital Display: Clear and easy-to-read big display for monitoring time and program status.
  • Clock Correction/Calibration: Functionality to maintain accurate timekeeping.
  • Keyboard Lock: Prevents accidental changes to programmed settings.
  • Durable Construction: Features long-life silicone buttons and a high-power relay for extended service life.
  • Battery Backup: Built-in 3V rechargeable battery provides up to 60 days of blackout memory.
  • Wide Application: Suitable for automatic control of street lights, neon lights, production equipment, radio and television, and other electrical appliances.

3. Setup and Installation

Important Safety Information: Before proceeding with installation, ensure that the main power supply is disconnected to prevent electrical shock. Installation should only be performed by a qualified electrician or a knowledgeable individual familiar with electrical wiring.

3.1 Wiring Diagram

The TM612 timer switch features 6 pins for connection. Refer to the diagram below for proper wiring. The device operates on a 220-250 VAC power supply.

Front view of the RWRAPS TM612 timer switch showing the display, buttons, and wiring terminals.

Figure 1: Front view of the RWRAPS TM612 timer switch. This image displays the digital screen, control buttons (Menu, Res, directional arrows, OK), and the terminal block connections at the top and bottom for power input and relay outputs. The model number "TM-612 top" is visible on the side.

  • Power Input (L, N): Connect the live (L) and neutral (N) wires from your 220-250 VAC power source to the corresponding terminals.
  • Relay Outputs (C1, 1, 2, C2, 4, 5): The TM612 has two independent relay outputs. Each relay has a common (C), normally open (NO), and normally closed (NC) contact.
    • Relay 1: C1 (Common), 1 (Normally Open), 2 (Normally Closed)
    • Relay 2: C2 (Common), 4 (Normally Open), 5 (Normally Closed)
    Connect your load (e.g., light, motor) to the appropriate relay contacts based on whether you need it to turn ON when the timer activates (NO) or turn OFF (NC).

3.2 Initial Power-Up

Upon initial power-up or after a prolonged power outage, the display may be blank. The internal rechargeable battery will charge automatically. Allow a few minutes for the display to activate. If the display remains blank, press the "Res" button to reset the device.

RWRAPS TM612 timer switch next to its retail packaging box.

Figure 2: The TM612 timer switch displayed alongside its product packaging. This image displays the digital screen, control buttons, and terminal block connections, indicating its compact size and design.

4. Operating Instructions

4.1 Setting Current Time and Day

  1. Press the "Menu" button to enter the main menu.
  2. Use the "+" or "-" buttons to navigate to the "Time" setting.
  3. Press "OK" to select.
  4. The hour digit will flash. Use "+" or "-" to adjust the hour. Press "OK" to confirm and move to minutes.
  5. Adjust minutes and then the day of the week (1=Monday, 7=Sunday) using the same method.
  6. Press "Menu" to exit and save settings.

4.2 Programming ON/OFF Schedules

The TM612 supports up to 44 ON/OFF programs. Each program consists of an ON time and an OFF time for a specific day or group of days.

  1. Press the "Menu" button.
  2. Navigate to "Program" using "+" or "-". Press "OK".
  3. The display will show "1 ON". This is your first ON program.
  4. Use "+" or "-" to set the desired ON hour, then press "OK". Repeat for minutes.
  5. Next, select the day(s) for this program. You can choose:
    • Specific day (e.g., Mon, Tue)
    • Weekdays (Mon-Fri)
    • Weekends (Sat-Sun)
    • Every day (Mon-Sun)
    • Custom combinations
    Use "+" or "-" to cycle through options, then "OK" to confirm.
  6. After setting the ON time and day(s), the display will show "1 OFF". Set the desired OFF hour and minutes using the same method.
  7. Press "OK" to confirm the OFF time.
  8. The display will now show "2 ON", ready for the next program. Repeat steps 4-7 for additional programs.
  9. To exit programming mode and save, press "Menu".

Note: If you do not set an OFF time for an ON program, the device will remain ON until the next programmed OFF time or until manually switched.

4.3 Manual Override

The TM612 allows for manual override of the current ON/OFF state without affecting programmed schedules. This is typically done via a dedicated button or a combination of buttons (e.g., pressing "OK" outside of menu mode).

Look for a button labeled "Manual" or "Mode" or try pressing the "OK" button when the device is displaying the current time. Each press will cycle through states like ON, OFF, AUTO ON, AUTO OFF.

Side view of the RWRAPS TM612 timer switch, showing its compact profile and DIN rail mounting clips.

Figure 3: Side profile of the TM612 timer switch. This view highlights the compact design and the integrated clips for easy mounting on a DIN rail, common in electrical enclosures.

5. Maintenance

  • Cleaning: Use a soft, dry cloth to clean the exterior of the timer switch. Do not use abrasive cleaners, solvents, or spray directly onto the device.
  • Battery: The internal rechargeable battery is designed for long life and typically does not require replacement. Ensure the device is regularly connected to power to keep the battery charged.
  • Environment: Operate the device within its specified temperature range (-10°C to +50°C) and avoid environments with excessive dust, moisture, or corrosive gases.
  • Inspection: Periodically inspect the wiring connections to ensure they are secure and free from corrosion.
Back and bottom view of the RWRAPS TM612 timer switch, showing the mounting mechanism and additional terminal details.

Figure 4: Rear and bottom view of the TM612 timer switch. This perspective shows the back casing, ventilation slots, and the lower set of wiring terminals, providing a comprehensive view of its physical structure.

6. Troubleshooting

ProblemPossible CauseSolution
Display is blank.No power supply; internal battery discharged.Check power connections. Allow device to charge for a few minutes. Press the "Res" (Reset) button.
Programs not executing.Incorrect time/day setting; program not saved; manual override active; wiring issue.Verify current time and day. Re-enter and save programs. Check if the device is in "AUTO" mode. Inspect wiring connections.
Device does not respond to button presses.Keyboard lock active; internal malfunction.Check for keyboard lock (refer to manual for specific unlock procedure, usually a long press or combination). Try pressing the "Res" button. If issue persists, contact support.
Time drifts significantly.Environmental factors; internal clock issue.Ensure device is within operating temperature range. The device has a clock correction function; if drift is excessive, contact support.

7. Technical Specifications

ParameterValue
ModelTM612
Temperature Range-10°C to +50°C
Power Supply220-250 VAC
Power Consumption4.5VA (MAX)
Switching Contact2 changeover switches (2NO 2NC)
Programs44 ON/OFF per day or week
Hysteresis2 sec/day (at 25°C)
Minimum Interval1 Minute
Capacity16A 250V AC
Black-out Memory60 days (with fully charged internal battery)
Timer Range1 minute to 168 hours
Recharge Battery3 V
Average Error±1 second / 24 hours (at 25°C)
Weight0.175 kg (6.2 ounces)
MaterialSilicone (for buttons)
Three RWRAPS timer switches, including the TM612, displayed side-by-side.

Figure 5: A comparative view of multiple RWRAPS timer switches, including the TM612. This image illustrates the consistent design language across the product line and their compact form factor suitable for various installations.

8. Warranty and Support

For warranty information, technical support, or service inquiries regarding your RWRAPS TM612 Programmable Timer Switch, please contact the manufacturer or your point of purchase. Keep your purchase receipt as proof of purchase for warranty claims.

For the most up-to-date support resources, visit the official RWRAPS website or refer to the contact information provided with your product packaging.

© 2023 RWRAPS. All rights reserved.

This manual is subject to change without notice.