1. Introduction and Overview
The VENLAB VM500A is a versatile 6000-count True RMS digital multimeter designed for accurate and reliable electrical measurements. It is suitable for a wide range of applications, from household use to industrial settings, including automotive circuit troubleshooting and testing electronics. This manual provides detailed instructions for safe and effective operation of your multimeter.

Figure 1.1: VENLAB VM500A Digital Multimeter and accessories.
Key Features:
- Measures AC/DC Current & Voltage, Frequency, Battery, Resistance, Continuity, Diode, Capacitance, and Temperature.
- CAT III 600V safety rating with CE and RoHS certification.
- Equipped with double fuses for anti-burning and overload protection.
- Non-Contact Voltage (NCV) function for enhanced safety.
- Features data hold, hanging magnet, rubber sleeve support stand, continuity buzzer, auto power-off.
- Built-in backlight LCD display and flashlight for clear readings in low-light conditions.

Figure 1.2: Key features of the VM500A Multimeter.
2. Safety Information
WARNING: To avoid possible electric shock, fire, or personal injury, please read all safety information before you use the product. Improper use of this meter can cause damage, shock, injury or death. Always follow all safety precautions.
- Do not exceed the maximum input value specified for each range.
- Use caution when working with voltages above 30V AC RMS, 42V peak, or 60V DC. Such voltages pose a shock hazard.
- Before measuring current, ensure the meter's fuses are intact and the test leads are connected to the correct input jacks.
- Always disconnect the test leads from the circuit before changing functions.
- Inspect the test leads for damaged insulation or exposed metal before use. Replace if damaged.
- Do not operate the meter if it appears damaged or if it is not operating properly.
- Ensure the battery cover is securely closed before operation.
3. Product Components and Parts Identification
Familiarize yourself with the components of your VENLAB VM500A Digital Multimeter:

Figure 3.1: Front view of the VM500A Multimeter with labeled parts.
- LCD Display: Shows measurement readings, units, and function indicators.
- NCV Sensor: Detects non-contact voltage.
- Flashlight: Illuminates the work area.
- NCV Indicator Light: Illuminates when NCV is detected.
- Hold Button: Freezes the current display reading.
- Function Choose Button (FUNC): Cycles through sub-functions within a rotary switch position.
- Backlight/Flashlight Button: Activates the display backlight and flashlight.
- Gear Rotary Switch: Selects the desired measurement function.
- Common Port (COM): Negative input terminal for all measurements.
- 10A Port: Input terminal for high current (up to 10A) measurements.
- Input Port (VΩmA): Positive input terminal for voltage, resistance, capacitance, diode, continuity, frequency, and low current (mA) measurements.
- Built-in Dual Ceramic Fuse: Provides anti-burning and overload protection.
4. Setup
4.1 Unpacking and Inspection
Upon receiving your VENLAB VM500A Digital Multimeter, carefully unpack all contents and inspect for any damage. The package should include:
- 1 x VENLAB VM500A Digital Multimeter
- 1 x Pair of Test Leads (Red and Black)
- 1 x Thermocouple (for temperature measurement)
- Batteries (AAA)
- Spare Fuses
- User Manual

Figure 4.1: Complete accessories included with the VM500A Multimeter.
4.2 Battery Installation
The VM500A multimeter requires 3 AAA batteries for operation. To install or replace batteries:
- Ensure the multimeter is turned OFF.
- Locate the battery compartment on the back of the multimeter.
- Use a screwdriver to loosen the screw securing the battery cover.
- Remove the battery cover.
- Insert the 3 AAA batteries, observing the correct polarity (+/-) as indicated inside the compartment.
- Replace the battery cover and tighten the screw securely.
Video 4.1: Demonstrates battery installation and fuse inspection for the VENLAB VM500A Digital Multimeter.
5. Operating Instructions
This section details how to use the various measurement functions of your VM500A Digital Multimeter.
5.1 General Operation Tips
- Always select the appropriate function and range before connecting the test leads to the circuit.
- Connect the black test lead to the COM jack.
- Connect the red test lead to the VΩmA jack for voltage, resistance, capacitance, diode, continuity, frequency, and low current measurements.
- Connect the red test lead to the 10A jack for high current measurements (up to 10A).
- Use the 'HOLD' button to freeze the display reading.
- Press the 'Backlight/Flashlight' button to activate the display backlight or flashlight.
5.2 AC/DC Voltage Measurement
To measure AC or DC voltage:
- Turn the rotary switch to the 'V' position (AC or DC, auto-ranging).
- Connect the black test lead to the COM jack and the red test lead to the VΩmA jack.
- Connect the test probes across the circuit or component to be measured.
- The display will show the voltage reading.

Figure 5.1: Performing AC/DC Voltage Test.
5.3 AC/DC Current Measurement
To measure AC or DC current:
- Turn the rotary switch to the 'A' or 'mA' position (AC or DC, auto-ranging).
- For currents up to 600mA, connect the red test lead to the VΩmA jack. For currents up to 10A, connect the red test lead to the 10A jack. Always connect the black test lead to the COM jack.
- Open the circuit where current is to be measured and connect the meter in series with the circuit.
- The display will show the current reading.

Figure 5.2: Performing AC/DC Current Test.
5.4 Resistance Measurement
To measure resistance:
- Turn the rotary switch to the 'Ω' position.
- Connect the black test lead to the COM jack and the red test lead to the VΩmA jack.
- Connect the test probes across the component to be measured. Ensure the circuit is de-energized before measuring resistance.
- The display will show the resistance reading.

Figure 5.3: Demonstrating Resistance, Continuity, Diode, Capacitance, Temperature, and NCV Tests.
5.5 Continuity Test
To test for continuity:
- Turn the rotary switch to the 'Ω' position and press 'FUNC' until the continuity symbol (speaker icon) appears.
- Connect the black test lead to the COM jack and the red test lead to the VΩmA jack.
- Connect the test probes across the circuit or component.
- If continuity exists (resistance below approximately 50Ω), the buzzer will sound.
5.6 Diode Test
To test a diode:
- Turn the rotary switch to the 'Ω' position and press 'FUNC' until the diode symbol appears.
- Connect the black test lead to the COM jack and the red test lead to the VΩmA jack.
- Connect the red probe to the anode and the black probe to the cathode of the diode. The display will show the forward voltage drop.
- Reverse the probes. The display should show 'OL' (Overload) for a good diode.
5.7 Capacitance Measurement
To measure capacitance:
- Turn the rotary switch to the 'Capacitance' position.
- Connect the black test lead to the COM jack and the red test lead to the VΩmA jack.
- Connect the test probes across the capacitor. Ensure the capacitor is fully discharged before testing.
- The display will show the capacitance reading.
5.8 Temperature Measurement
To measure temperature:
- Turn the rotary switch to the 'Temp' position.
- Connect the thermocouple to the VΩmA and COM jacks, observing polarity.
- Place the thermocouple sensor at the location where temperature is to be measured.
- The display will show the temperature reading in Celsius (°C) or Fahrenheit (°F). Press 'FUNC' to switch between units.
Video 5.4: Demonstrates temperature measurement using the included thermocouple.
5.9 Non-Contact Voltage (NCV) Test
To perform an NCV test:
- Turn the rotary switch to the 'NCV' position.
- Move the NCV sensor (top of the meter) close to the conductor or outlet you want to test.
- The NCV indicator light will illuminate and the buzzer will sound, with increasing frequency as the voltage strength increases.

Figure 5.5: Performing Non-Contact Voltage (NCV) Test.
5.10 Frequency Measurement
To measure frequency:
- Turn the rotary switch to the 'Hz' position.
- Connect the black test lead to the COM jack and the red test lead to the VΩmA jack.
- Connect the test probes across the circuit where frequency is to be measured.
- The display will show the frequency reading. In AC voltage mode, a long press of the FUNC key can also measure the frequency.

Figure 5.6: Performing Frequency Test.
5.11 Battery Voltage Test (1.5V, 9V, 12V)
To test battery voltage:
- Turn the rotary switch to the '1.5V', '9V', or '12V' battery test position.
- Connect the black test lead to the COM jack and the red test lead to the VΩmA jack.
- Connect the test probes to the positive and negative terminals of the battery.
- The display will show the battery voltage. If the battery voltage is lower than 20% of the nominal voltage, the battery is considered exhausted.

Figure 5.7: Performing Battery Voltage Test.

Figure 5.8: Real-time Battery Voltage Test results.
6. Maintenance
6.1 Cleaning
To clean the meter, wipe the case with a damp cloth and mild detergent. Do not use abrasives or solvents. Keep the input terminals free of dirt or moisture.
6.2 Fuse Replacement
The VM500A is equipped with dual ceramic fuses for protection. If the meter fails to measure current, the fuse may be blown. To replace the fuse:
- Ensure the multimeter is turned OFF and all test leads are disconnected.
- Locate the battery compartment on the back of the multimeter.
- Use a screwdriver to loosen the screw securing the battery cover and remove the cover.
- Carefully remove the old fuse(s). Note the fuse ratings.
- Install new fuses of the same type and rating. The VM500A uses two fuses: one for the 10A range and one for the mA range.
- Replace the battery cover and tighten the screw securely.
Video 6.1: Demonstrates fuse inspection and replacement for the VENLAB VM500A Digital Multimeter.
6.3 Storage
When not in use for extended periods, turn off the multimeter and remove the batteries to prevent leakage and damage to the device.
7. Troubleshooting
If you encounter issues with your VM500A Digital Multimeter, refer to the following common problems and solutions:
| Problem | Possible Cause | Solution |
|---|---|---|
| Meter does not power on. | Dead or incorrectly installed batteries. | Check battery polarity, replace batteries. |
| No reading or 'OL' (Overload) displayed in a measurement range. | Incorrect range selected; open circuit; blown fuse (for current). | Select appropriate range; check circuit continuity; check/replace fuses. |
| Inaccurate readings. | Poor test lead connection; external interference; low battery. | Ensure firm connections; move away from strong electromagnetic fields; replace batteries. |
| Buzzer not sounding during continuity test. | Circuit resistance too high; meter not in continuity mode. | Check circuit resistance; ensure rotary switch is in 'Ω' and FUNC button is pressed to select continuity. |
8. Specifications
| Specification | Value |
|---|---|
| Model Number | VM500A |
| Display | 6000 Counts |
| Safety Rating | CAT III 600V |
| Power Source | Battery Powered (3 x AAA) |
| Package Dimensions | 6.77 x 4.41 x 2.13 inches |
| Item Weight | 12.63 ounces |
| Min. Operating Voltage | 3 Volts |
9. Warranty and Support
VENLAB provides a lifetime after-sale service and technical support for the VM500A Digital Multimeter. For any inquiries, technical assistance, or warranty claims, please contact VENLAB customer service through the official channels provided at the time of purchase or visit the VENLAB store on Amazon.
Your satisfaction is our priority. Please retain your purchase receipt as proof of purchase for warranty purposes.