BSIDE H3 Industrial Thermometer IR

BSIDE H3 Infrared Thermometer User Manual

Model: H3 Industrial Thermometer IR

Brand: BSIDE

1. Introduction

The BSIDE H3 Infrared Thermometer is a professional non-contact digital pyrometer designed for accurate temperature measurement across a wide range of applications. Featuring a high distance-to-spot ratio, adjustable emissivity, and various measurement functions, it provides reliable temperature readings for industrial, automotive, and domestic use.

1.1 Safety Information

  • Do not point the laser directly at eyes or indirectly off reflective surfaces.
  • Do not use the device near explosive gas, vapor, or dust.
  • Do not immerse the unit in water or other liquids.
  • Always ensure proper battery installation and disposal.
  • Keep out of reach of children.

2. Package Contents

Verify that all items are present in the package:

  • 1 x BSIDE H3 Infrared Thermometer
  • 1 x Carrying Case
  • 2 x AAA Batteries
  • 1 x User Manual
BSIDE H3 Infrared Thermometer package contents including the thermometer, carrying case, batteries, and user manual.

Image: Contents of the BSIDE H3 Infrared Thermometer package, showing the device, its protective carrying case, two AAA batteries, and the instruction manual.

3. Product Overview

The BSIDE H3 Infrared Thermometer is designed for ease of use and accurate readings. It features a color LCD display, laser pointer for targeting, and intuitive controls.

Front view of the BSIDE H3 Infrared Thermometer with its display showing temperature readings, alongside two AAA batteries and a carrying case.

Image: The BSIDE H3 Infrared Thermometer, a yellow and black handheld device, displayed with its included AAA batteries and a black zippered carrying case.

3.1 Key Features

  • Color LCD Display for enhanced readability.
  • Non-contact infrared measurement.
  • High Distance-to-Spot Ratio (D:S = 50:1).
  • Wide temperature range: -58℉ to 2552℉ (-50℃ to 1400℃).
  • Switchable Celsius and Fahrenheit units.
  • High and Low Temperature Alarm functions (HAL/LAL).
  • Adjustable Emissivity.
  • MAX/MIN/DIF/AVG measurement modes.
  • Auto power-off, backlight, and low battery indication.

4. Specifications

ParameterValue
Screen TypeColor LCD Display
Measurement Range-58℉ to 2552℉ (-50℃ to 1400℃)
Distance to Spot Ratio (D:S)50:1
Accuracy±2% (for >100℃); ±2℃ (for <100℃)
Resolution0.1℃ / 0.1℉
Response Time0.5 seconds
FunctionsHAL/LAL/MAX/MIN/AVG/DIF
Power2 x 1.5V AAA Batteries
Product Dimensions16.1 x 7.8 x 2.4 cm
Weight183g (without batteries) / 194g (with batteries)
MaterialAcrylonitrile Butadiene Styrene (ABS)

5. Setup

5.1 Battery Installation

The BSIDE H3 Infrared Thermometer requires two 1.5V AAA batteries for operation. Batteries are included in the package.

  1. Locate the battery compartment cover on the handle of the thermometer.
  2. Slide the cover open in the direction indicated by the arrow.
  3. Insert two AAA batteries, ensuring correct polarity (+ and -) as marked inside the compartment.
  4. Close the battery compartment cover securely until it clicks into place.

Note: If the low battery indicator appears on the display, replace the batteries promptly to ensure accurate readings.

6. Operating Instructions

6.1 Taking a Measurement

  1. Hold the thermometer by the handle and point the laser beam at the target surface.
  2. Press and hold the trigger to begin scanning. The temperature reading will appear on the color LCD display.
  3. Release the trigger to hold the last measured temperature on the display. The "HOLD" icon will appear.
  4. The device will automatically power off after a period of inactivity to conserve battery life.
A person using the BSIDE H3 Infrared Thermometer to measure the temperature of molten metal in a casting environment.

Image: The BSIDE H3 Infrared Thermometer in use, demonstrating its application in measuring high temperatures in industrial settings, such as molten metal in a crucible.

6.2 Distance to Spot Ratio (D:S = 50:1)

The D:S ratio indicates the size of the area being measured relative to the distance from the thermometer. A 50:1 D:S ratio means that at a distance of 50 units, the measurement spot diameter is 1 unit. This allows for accurate temperature measurement of smaller targets from a safer distance.

Diagram explaining the 50:1 Distance to Spot Ratio (D:S) of the infrared thermometer, showing how the measured spot size increases with distance.

Image: A visual representation of the 50:1 Distance to Spot Ratio, illustrating that the measured spot diameter (S) is 1/50th of the distance (D) from the thermometer to the target. This allows for precise measurement from a safe distance.

6.3 Mode Functions (MAX/MIN/DIF/AVG)

Press the MODE button to cycle through different measurement functions:

  • MAX: Displays the maximum temperature recorded during the scanning period.
  • MIN: Displays the minimum temperature recorded during the scanning period.
  • DIF: Displays the difference between the maximum and minimum temperatures recorded.
  • AVG: Displays the average temperature recorded during the scanning period.

6.4 High/Low Temperature Alarm (HAL/LAL)

The thermometer can be set to alarm when the measured temperature exceeds a high limit (HAL) or falls below a low limit (LAL).

  1. Press the SET button to enter the alarm setting mode.
  2. Use the UP and DOWN arrows to adjust the HAL or LAL values.
  3. Press SET again to confirm and switch between HAL and LAL settings.
  4. When the measured temperature goes beyond the set limits, an audible and/or visual alarm will activate.
Diagram illustrating the High Temperature Alarm (HAL) at 1400°C/2552°F and Low Temperature Alarm (LAL) at -50°C/-58°F settings on the BSIDE H3 Infrared Thermometer.

Image: A graphical representation showing the High Temperature Alarm (HAL) set at 1400°C/2552°F and the Low Temperature Alarm (LAL) set at -50°C/-58°F, indicating the device's ability to alert users when temperatures fall outside a specified range.

6.5 Celsius/Fahrenheit Switching

To switch between Celsius (℃) and Fahrenheit (℉) units, press the ℃/℉ button located on the control panel.

6.6 Emissivity Adjustment (EMS)

Emissivity is a measure of an object's ability to emit infrared energy. Different materials have different emissivity values. For accurate readings, adjust the emissivity setting (EMS) to match the material being measured. Refer to standard emissivity tables for common materials.

  • Press the EMS button to enter emissivity adjustment mode.
  • Use the UP and DOWN arrows to change the value (typically from 0.10 to 1.00).
  • Press EMS again or wait for a few seconds to exit the setting.

7. Applications

The BSIDE H3 Infrared Thermometer is suitable for a wide range of non-contact temperature measurement applications, including but not limited to:

  • HVAC: Checking heating, ventilation, and air conditioning systems.
  • Industrial: Monitoring temperatures in manufacturing processes, machinery, and equipment.
  • Metal Casting & Smelting: Measuring temperatures of molten metals and furnaces.
  • Forge Industry: Assessing temperatures in forging and heat treatment processes.
  • Automotive Maintenance: Diagnosing engine components, brakes, and cooling systems.
  • Kitchen & Cooking: Checking surface temperatures of grills, ovens, and frying pans (not for internal food temperature).
  • Home Inspection: Identifying insulation issues, hot spots, or cold drafts.
The BSIDE H3 Infrared Thermometer being used in a forging industry setting, measuring the temperature of hot metal with sparks visible.

Image: The BSIDE H3 Infrared Thermometer in action within a forging industry environment, accurately measuring the temperature of a heated metal piece, highlighting its utility in high-temperature industrial applications.

The BSIDE H3 Infrared Thermometer being used for automotive maintenance, pointing at an engine component to measure its temperature.

Image: The BSIDE H3 Infrared Thermometer being used for automotive maintenance, demonstrating its ability to easily measure the temperature of car engine components.

The BSIDE H3 Infrared Thermometer being used in a metal fabrication setting, measuring the temperature of a metal piece being worked on.

Image: The BSIDE H3 Infrared Thermometer in use during metal fabrication, precisely measuring the temperature of a metal workpiece, showcasing its versatility in industrial applications.

8. Maintenance

  • Cleaning: Use a soft, damp cloth to clean the device casing. Do not use abrasive cleaners or solvents.
  • Lens Care: The infrared lens is the most delicate part. Clean it carefully with a soft cloth or cotton swab and water or medical alcohol. Do not scratch the lens.
  • Storage: When not in use for extended periods, remove the batteries to prevent leakage. Store the thermometer in its carrying case in a cool, dry place, away from direct sunlight and extreme temperatures.
  • Do Not Soak: As per product care instructions, do not soak the device in any liquid.

9. Troubleshooting

ProblemPossible CauseSolution
Device does not turn on.Dead or incorrectly installed batteries.Replace batteries, ensuring correct polarity.
Inaccurate readings.Incorrect emissivity setting; lens is dirty; distance to spot ratio not optimal.Adjust emissivity; clean the lens; ensure proper distance from target.
Laser not visible.Laser function is off or obstructed.Check settings to ensure laser is enabled; clear any obstructions.
Display is dim or flickering.Low battery.Replace batteries.

10. Warranty and Support

BSIDE products are manufactured to high quality standards. For information regarding warranty coverage, technical support, or service, please refer to the contact information provided on the product packaging or visit the official BSIDE website. Please retain your purchase receipt as proof of purchase for warranty claims.

For any issues not covered in this manual, please contact customer support.

© 2024 BSIDE. All rights reserved.

This manual is subject to change without notice.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.