rackchoice 5U-RC-Silver

RackChoice 5U Rackmount Server Chassis User Manual

Model: 5U-RC-Silver

Introduction

This manual provides comprehensive instructions for the installation, operation, and maintenance of your RackChoice 5U Rackmount Server Chassis. Designed for server applications, this chassis offers robust construction and compatibility with various components, including advanced liquid cooling systems.

Please read this manual thoroughly before beginning installation to ensure proper setup and to maximize the performance and longevity of your server chassis.

RackChoice 5U Rackmount Server Chassis, front-side view

Image: Front-side view of the RackChoice 5U Rackmount Server Chassis, showcasing its silver color and robust design.

Setup and Installation

Follow these steps for proper installation of components within your server chassis.

1. Motherboard Installation

The chassis supports EATX, ATX, MicroATX, and Mini-ITX motherboards. Carefully align your motherboard with the standoffs and secure it with screws.

2. Power Supply Unit (PSU) Installation

This chassis accommodates one standard PS2 ATX PSU and one SFX PSU. Install the PSUs into their designated bays. Ensure proper cable management for optimal airflow.

Internal view of RackChoice 5U chassis showing PSU space

Image: Internal view of the chassis highlighting the dedicated space for ATX and SFX power supply units. The ATX PSU space is 220.8mm between the SFX PSU bracket and the rear panel.

3. Drive Bay Configuration

The chassis includes 2 internal 3.5-inch drive bays, with an option for 2 additional 3.5-inch drives. Install your hard drives or SSDs securely into the available bays.

4. Cooling System Setup

The chassis is designed for extensive cooling, including liquid cooling. It supports up to 360mm liquid cooling radiators.

  • Front Cooling: Three 120mm fans can be installed at the front for liquid cooling radiators.
  • Middle Cooling: Two 120mm fans are pre-installed in the middle section.
  • Rear Cooling: Optional installation of one 120mm fan and two 80mm fans at the rear.
Internal view of RackChoice 5U chassis showing liquid cooling spaces

Image: Internal view illustrating the liquid cooling compatibility. The chassis supports 2x360mm or 1x360mm + 1x240mm liquid cooling space at the top, and an additional 1x240mm liquid cooling space. Optional 1x120mm + 2x80mm fans can be installed. Note: Motherboard, HDD, PSU, and liquid cooling components are not included with the chassis.

Top-down internal view of RackChoice 5U chassis

Image: Top-down internal view of the chassis, showing the layout for components and pre-installed middle fans.

Operation

Once all components are installed and secured, connect the necessary power and data cables. The chassis features a front panel with a thermal LCD display.

Front Panel Thermal LCD

The front panel includes a thermal LCD display that provides real-time temperature readings and operational status. This allows for quick monitoring of your system's thermal performance.

RackChoice 5U chassis front panel with thermal LCD highlighted

Image: Front view of the RackChoice 5U chassis, with a red circle highlighting the thermal LCD display on the front panel, showing temperature (e.g., 30°C) and run time.

Maintenance

Regular maintenance ensures optimal performance and extends the lifespan of your server chassis.

  • Dust Removal: Periodically clean the interior of the chassis and fan filters to prevent dust buildup, which can impede airflow and lead to overheating. Use compressed air or a soft brush.
  • Cable Management: Ensure cables are neatly organized to maintain proper airflow and prevent interference with cooling components.
  • Fan Inspection: Check fans regularly for proper operation. Replace any noisy or malfunctioning fans.
  • Component Security: Verify that all installed components (motherboard, drives, PSUs) remain securely fastened.

Troubleshooting

This section addresses common issues you might encounter.

  • No Power:
    • Check all power connections, including the PSU to the wall outlet and internal component power cables.
    • Verify that the PSU switch is in the 'ON' position.
  • Overheating:
    • Ensure all fans are spinning correctly.
    • Clean dust from fans and vents.
    • Verify proper installation of liquid cooling components if used.
    • Check thermal paste application on CPU/GPU.
  • Component Not Detected:
    • Reseat the component (e.g., RAM, GPU, drive).
    • Check data and power cable connections to the component.
    • Verify compatibility with your motherboard.

Specifications

Feature Detail
Brand rackchoice
Model 5U Rackmount Server Chassis
Product Dimensions 19.68"D x 19"W x 8.75"H (500mm D x 482.6mm W x 222.25mm H)
Material Alloy Steel
Item Weight 15.3 Pounds (6.94 kg)
Compatible Devices Server
Motherboard Support EATX/ATX/MicroATX/Mini-ITX
Drive Bays 2 x 3.5" (internal) + 2 x 3.5" (optional)
PSU Support 1 x Standard PS2 ATX + 1 x SFX
Liquid Cooling Radiator Support Up to 360mm (Front: 3x120mm, Top: 2x360mm or 1x360mm+1x240mm, Internal: 1x240mm)
Cooling System (Fans) 3 x 120mm (front, for liquid), 2 x 120mm (pre-installed in middle), 1 x 120mm & 2 x 80mm (rear, optional)
Front Panel Features Thermal LCD display
RackChoice 5U chassis dimensions diagram

Image: Diagram showing the dimensions of the RackChoice 5U Rackmount Server Chassis: 19 inches (width), 220mm (height), and 500mm (depth).

Warranty and Support

For warranty information and technical support, please refer to the official RackChoice website or contact your point of purchase. Keep your proof of purchase for warranty claims.

No official product videos from the seller were found to be included in this manual.

Related Documents - 5U-RC-Silver

Preview 5502 Model 2U Rackmount Server Chassis Technical Specifications and Dimensions
Detailed technical drawings and dimensions for the 5502 Model 2U rackmount server chassis by RackChoice, supporting ATX/MATX motherboards and ATX PSUs. Includes front, side, top/bottom, and isometric views with component descriptions.
Preview SilverStone RM52 5U Rackmount Server Chassis User Manual and Installation Guide
Comprehensive user manual for the SilverStone RM52 5U rackmount server chassis, detailing installation steps, parts list, compatibility information, and warranty details.
Preview Silverlab Nebulising Liquid 25 ppm Patient Information Leaflet
Patient information leaflet for Silverlab Nebulising Liquid 25 ppm, a complementary health product containing ionic colloidal silver for respiratory discomfort and immune support. Includes usage instructions, side effects, storage, and manufacturer information.
Preview Fujitsu PRIMERGY TX2550 M7 システム構成図と仕様
富士通 PRIMERGY TX2550 M7 サーバの詳細なシステム構成図、仕様、およびコンポーネントオプションに関する情報を提供します。ビジネスおよびデータセンター環境向けの高性能サーバー構成の検討にご活用ください。
Preview DSC8000-5U Installation Guide
Instructions for installing the DSC8000-5U system, focusing on securing the main control card and chassis.