1. Introduction

This manual provides detailed instructions for the Berrcom JXB183 Non-Contact Forehead Thermometer and the Berrcom DT007 Digital Thermometer. Please read this manual thoroughly before using the devices to ensure accurate measurements and safe operation. Keep this manual for future reference.

Berrcom JXB183 Non-Contact Forehead Thermometer and Berrcom DT007 Digital Thermometer bundle

Figure 1: Berrcom Thermometer Bundle (JXB183 and DT007).

2. Safety Information

3. Berrcom JXB183 Non-Contact Forehead Thermometer

3.1 Product Features

3.2 Components

Berrcom JXB183 Non-Contact Forehead Thermometer with its packaging

Figure 2: Berrcom JXB183 Thermometer and its packaging.

Diagram showing features of Berrcom JXB183 including instant measurement, non-contact, 3 modes, 32 memory, fever alarm, beep, auto shut-off, and switchable units.

Figure 3: Key features of the JXB183 thermometer.

The JXB183 features a clear LCD display, mode and memory buttons, and a scan button for taking measurements. The infrared sensor is located at the top of the device.

4. Berrcom DT007 Digital Thermometer

4.1 Product Features

4.2 Components

Berrcom DT007 Digital Thermometer

Figure 4: Berrcom DT007 Digital Thermometer.

Diagram showing components of Berrcom DT007: cap, smart button, LCD screen, sensor, and ABS material.

Figure 5: Components of the DT007 thermometer.

The DT007 features a flexible tip with a sensor, an LCD screen for displaying readings, and a power/mode button. It is designed for oral, axillary (armpit), and rectal temperature measurements.

5. Setup and Initial Use

5.1 Battery Installation

Both thermometers require batteries for operation. Refer to the battery compartment on each device for specific battery type and installation instructions. Ensure correct polarity when inserting batteries.

5.2 JXB183 Initial Settings (°F/°C)

To switch between Fahrenheit (°F) and Celsius (°C) on the JXB183, power on the device. While the device is on, press and hold the "MODE" button for a few seconds until the unit changes. Release the button when your desired unit is displayed.

Berrcom JXB183 showing switchable Fahrenheit and Celsius units.

Figure 6: Switching between Fahrenheit and Celsius on JXB183.

6. Operating Instructions - Berrcom JXB183

6.1 Taking Body Temperature (Forehead)

  1. Ensure the thermometer is in Body Mode. Press the "MODE" button to cycle through modes if necessary.
  2. Hold the thermometer approximately 0.3 to 1.5 inches (1-3 cm) from the center of the forehead.
  3. Press the "SCAN" button once. The temperature will be displayed on the screen within 1 second.
  4. Wipe off any sweat or grease from the forehead before measuring for optimal accuracy.
Berrcom JXB183 showing Forehead Mode, Object Mode, and Room Mode.

Figure 7: JXB183 3-in-1 measurement modes.

6.2 Taking Object or Room Temperature

  1. Press the "MODE" button to select either Object Mode or Room Mode.
  2. Point the thermometer at the object or towards the room area you wish to measure.
  3. Press the "SCAN" button. The temperature will be displayed.

6.3 Interpreting Backlight Colors

Berrcom JXB183 display showing green, orange, and red backlights for different temperature ranges.

Figure 8: JXB183 backlight color indications.

6.4 Memory Recall

To view previous temperature readings, press the "MEM" button. Each press will cycle through the stored readings. The JXB183 can store up to 32 readings.

Berrcom JXB183 showing 32 reading memory feature with a graph of temperature tracking.

Figure 9: JXB183 32-reading memory function.

6.5 Mute/Unmute Function

The JXB183 has a mute function for silent operation. Refer to the device's specific button for this feature, often indicated by a speaker icon. Pressing it will toggle between mute and unmute.

7. Operating Instructions - Berrcom DT007

7.1 Taking Oral Temperature

  1. Press the power button to turn on the thermometer.
  2. Place the tip of the thermometer under the tongue, as far back as comfortable.
  3. Close lips around the thermometer to hold it in place.
  4. Wait for the thermometer to beep, indicating the measurement is complete. Read the temperature on the LCD screen.

7.2 Taking Axillary (Armpit) Temperature

  1. Press the power button to turn on the thermometer.
  2. Place the tip of the thermometer in the armpit, ensuring good skin contact.
  3. Hold the arm firmly against the body to keep the thermometer in place.
  4. Wait for the thermometer to beep, indicating the measurement is complete. Axillary temperatures are generally less accurate than oral or rectal readings.

7.3 Taking Rectal Temperature

Note: Rectal temperature is generally considered the most accurate for infants and young children.

  1. Press the power button to turn on the thermometer.
  2. Lubricate the tip of the thermometer with a water-soluble lubricant.
  3. Gently insert the tip no more than 0.5 inches (1.3 cm) into the rectum.
  4. Hold the thermometer in place until it beeps. Read the temperature on the LCD screen.
Berrcom DT007 being used for oral, armpit, and anal temperature measurements on babies.

Figure 10: DT007 usage for various measurement sites.

8. Maintenance and Storage

8.1 Cleaning

Berrcom DT007 digital thermometer in water, illustrating its waterproof design.

Figure 11: DT007 waterproof feature.

8.2 Storage

Store both thermometers in a cool, dry place, away from direct sunlight and extreme temperatures. Keep them in their protective cases (if provided) when not in use.

8.3 Battery Replacement

Replace batteries when the low battery indicator appears on the display. Follow the instructions in the battery compartment for safe replacement. Dispose of used batteries according to local regulations.

9. Troubleshooting

ProblemPossible CauseSolution
JXB183: Inaccurate readingsDirty sensor, incorrect distance, sweat/hair on forehead, ambient temperature fluctuations.Clean sensor, ensure correct measurement distance (0.3-1.5 inches), wipe forehead clean, ensure stable environment.
JXB183: Display shows "Lo" or "Hi"Temperature outside measurement range.Ensure measurement is within the specified operating range for body or object mode.
DT007: Inaccurate readingsImproper placement, movement during measurement, recent eating/drinking (oral).Ensure correct placement and stable position. Avoid eating/drinking 15 minutes prior to oral measurement.
Both: Device does not turn onDead batteries, incorrect battery installation.Replace batteries with new ones. Check battery polarity.
Both: Display is dim or flickeringLow battery.Replace batteries.

10. Specifications

Berrcom JXB183 Non-Contact Forehead Thermometer

Berrcom DT007 Digital Thermometer

11. Warranty and Support

Berrcom products are manufactured under strict quality standards. For warranty information or technical support, please refer to the contact details provided with your product packaging or visit the official Berrcom website. Please retain your proof of purchase for warranty claims.

For further assistance, you may contact Berrcom Medical Device, the seller, through the Amazon platform.

Related Documents - JXB183, DT007

Preview Berrcom ET005 Infrared Ear and Forehead Thermometer User Manual
User manual for the Berrcom ET005 digital infrared thermometer. Learn about its features, how to accurately measure body temperature from the ear or forehead, maintenance, technical specifications, and warranty information provided by Guangzhou Berrcom Medical Device Co., Ltd.
Preview Berrcom JXB-311 Non-contact Infrared Thermometer User Manual
Comprehensive user manual for the Berrcom JXB-311 non-contact infrared thermometer, covering setup, operation, troubleshooting, specifications, and warranty information.
Preview Berrcom DT007 Digital Thermometer User Manual | Instructions & Specifications
Comprehensive user manual for the Berrcom DT007 digital thermometer, covering setup, usage, technical specifications, cleaning, troubleshooting, and EMC compliance.
Preview Berrcom JXB-195 Non-contact Infrared Thermometer Instruction Manual
Comprehensive instruction manual for the Berrcom JXB-195 non-contact infrared thermometer. Learn about its intended use, safety precautions, operation modes, technical specifications, and maintenance for accurate forehead temperature readings in home and clinical settings.
Preview Berrcom JXB-182 Non-Contact Infrared Thermometer Instruction Manual
Comprehensive instruction manual for the Berrcom JXB-182 non-contact infrared thermometer. Covers intended use, safety precautions, operating instructions, technical specifications, maintenance, and disposal for accurate forehead temperature measurement in household and clinical settings.
Preview JXB-178 Non-Contact Infrared Thermometer User Guide
Comprehensive user guide for the Berrcom JXB-178 non-contact infrared thermometer, detailing its features, operating principles, measurement methods, technical specifications, and troubleshooting tips for accurate temperature readings.