Reznor UDXC-150

Reznor UDXC-150 Natural Gas Unit Heater: Installation and Operation Manual

Model: UDXC-150 | Brand: Reznor

1. Introduction

This manual provides essential information for the safe and efficient installation, operation, and maintenance of your Reznor UDXC-150 Natural Gas Unit Heater. Please read all instructions carefully before attempting to install or operate the unit. Retain this manual for future reference.

Front view of the Reznor UDXC-150 Natural Gas Unit Heater.

Figure 1: Front view of the Reznor UDXC-150 Natural Gas Unit Heater. This image displays the front and side view of the Reznor UDXC-150 Natural Gas Unit Heater, showcasing its compact design and air outlet.

2. Safety Information

WARNING: Improper installation, adjustment, alteration, service, or maintenance can cause property damage, injury, or death. Read the installation, operating, and maintenance instructions thoroughly before installing or servicing this equipment.

  • Ensure all local codes and ordinances are followed during installation.
  • Installation and service must be performed by a qualified installer, service agency, or gas supplier.
  • Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance.
  • This unit is designed for indoor use only.

3. Setup and Installation

The Reznor UDXC-150 unit heater is designed for versatile installation in commercial or industrial spaces. Proper setup is crucial for safe and efficient operation.

3.1 Mounting

The UDXC-150 is equipped with threaded-nut retainers at four suspension points, allowing for ceiling or wall mounting. Mounting brackets and hardware are sold separately and must be appropriate for the unit's weight and the structural integrity of the mounting surface.

Reznor UDXC-150 Unit Heater mounted on a ceiling, with a list of standard features.

Figure 2: Ceiling-mounted Reznor UDXC-150 Unit Heater. The heater is shown installed on a ceiling, illustrating its suspension points. Accompanying text lists features such as Status-Indicating LED Light, 7-Segment Display Board for troubleshooting, 2- and 4-Point Suspension Options, External Gas Connection, and ETL Approval.

3.2 Venting

This unit is compatible with category 1 double wall B-vent pipe. Venting can be configured vertically out of a roof or horizontally through a sidewall. Consult local codes for specific venting requirements.

3.3 Gas Connection

An external gas connection point is provided for ease of maintenance and installation. Ensure all gas connections are leak-free and comply with local regulations. This unit operates on Natural Gas.

3.4 Electrical Wiring

The unit features an external terminal strip for 24V wiring. All electrical work must be performed by a qualified electrician and adhere to all applicable electrical codes.

Image showing a worker installing a Reznor unit heater, with text about compact and durable heating.

Figure 3: Installation of the Reznor UDXC-150 Heater. A worker is shown connecting ductwork to a ceiling-mounted heater. The text emphasizes the unit's suitability for commercial/industrial spaces, corrosion-resistant materials, and quiet, efficient heating.

4. Operating Instructions

The Reznor UDXC-150 is designed for efficient and quiet heating.

4.1 Initial Startup

  1. Ensure all gas and electrical connections are secure and verified by a professional.
  2. Turn on the gas supply to the unit.
  3. Restore electrical power to the unit.
  4. Set the thermostat to the desired temperature. The unit will initiate its ignition sequence.

4.2 Normal Operation

  • The unit features a single-burner design with two BTU outputs, allowing for efficient heating in varying conditions.
  • An integrated circuit board with a display and a status-indicating LED provides operational feedback.
  • The low static pressure axial fan and power venting system ensure effective air circulation and minimize heat loss.
  • The unit operates with low noise due to vibration-isolated fan and venter motors.
Graphic detailing standard features of the Reznor UDXC-150 Unit Heater.

Figure 4: Key Features of the Reznor UDXC-150 Unit Heater. This graphic highlights key features including 83% AFUE Efficiency, TCORE2 Titanium-Stabilized Aluminized Steel Heat Exchanger, Multi-Try Direct Spark Ignition, and Low Noise Operation.

5. Maintenance

Regular maintenance ensures the longevity and optimal performance of your Reznor UDXC-150 unit heater. All maintenance should be performed by qualified personnel.

5.1 Routine Checks (Monthly/Quarterly)

  • Inspect the heat exchanger for any signs of corrosion or damage. The TCORE2 titanium-stabilized aluminized steel heat exchanger is designed for durability.
  • Check the fan and motor for unusual noises or vibrations.
  • Ensure the air intake and exhaust vents are clear of obstructions.
  • Verify that the external gas connection is secure and free of leaks.

5.2 Annual Servicing

  • A qualified technician should perform a comprehensive inspection and cleaning of the burner, heat exchanger, and ignition system.
  • The updated cabinet structure with a removable front face and hinged access door panel with a quarter-turn latch facilitate easier access for servicing.
  • Check and calibrate gas pressure as needed.
  • Inspect all electrical connections and wiring.

6. Troubleshooting

The UDXC-150 unit heater includes features to assist with troubleshooting common issues.

ProblemPossible CauseSolution
Heater does not igniteNo gas supply, electrical issue, ignition faultCheck gas valve, power supply. Consult 7-segment display for error codes.
Unit runs but no heatGas supply interrupted, burner issueVerify gas flow. Check burner for obstructions.
Unusual noises during operationFan imbalance, motor issue, loose componentsInspect fan and motor. Tighten any loose parts. If persistent, contact service.
Status LED indicates an errorSpecific fault detected by the control boardRefer to the 7-segment display board for specific error codes and consult the full service manual for detailed troubleshooting steps.

For complex issues or if the problem persists, contact a qualified service technician.

7. Specifications

FeatureDetail
Model NumberUDXC-150
Heat Output150,000 British Thermal Units (BTU)
Fuel TypeNatural Gas
Thermal Efficiency83%
Product Dimensions (D x W x H)48.44" x 38.19" x 20.13"
Mounting TypeCeiling Mount, Wall Mount (brackets sold separately)
Room TypeGarage, Warehouse, Commercial/Industrial Spaces
Special FeaturesEnergy Efficient, Fast Heating, Low Noise Operation, TCORE2 Titanium-Stabilized Aluminized Steel Heat Exchanger, 7-Segment Display Board
Number of Speeds2
Diagram showing the dimensions of the Reznor UDXC-150 Unit Heater.

Figure 5: Dimensions of the Reznor UDXC-150 Unit Heater. This image provides the physical dimensions of the 150,000 BTU unit, including its width, depth, and height, essential for installation planning.

8. Product Videos

No official product videos from the seller were found in the provided data for embedding in this manual.

9. Warranty Information

Specific warranty details for the Reznor UDXC-150 unit heater are typically provided at the point of purchase or included with the product packaging. Please refer to the warranty card or contact the seller (1HVAC) or Reznor directly for comprehensive warranty terms and conditions.

10. Support and Contact

For technical assistance, parts, or service inquiries, please contact the seller or an authorized Reznor service provider. Ensure you have your model number (UDXC-150) and serial number available when contacting support.

Seller: 1HVAC

For additional information, you may visit the 1HVAC Store on Amazon.

Two Reznor unit heaters, one with a fan visible, and text about product condition and packaging.

Figure 6: Product Condition and Packaging. This image shows two unit heaters, one from the front and one from the side revealing the fan. Text describes the careful handling in the 1HVAC warehouse and expert packaging to ensure product integrity during transit.

Related Documents - UDXC-150

Preview Reznor Gas Conversion Kit Installation for Gas-Fired Unit Heaters
This document provides installation instructions for Reznor gas conversion kits for various gas-fired unit heater models, including UBX, UBXC, UBZ, UDX, UDXC, UDZ, UDAP, UDAS, UDBP, and UDBS. It details component selection, safety precautions, and installation steps for converting between natural gas and propane, as well as for high-elevation installations.
Preview Reznor Ceiling Suspension Kit Installation Guide for Electric and Gas-Fired Unit Heaters
Installation instructions and component details for the Reznor CK22 Ceiling Suspension Kit, compatible with EHU electric and UDXC, UDX, UDZ gas-fired unit heaters. Learn how to safely mount your Reznor heater.
Preview Reznor Relay Kit Installation Guide for Multiple Unit Control (CL31/CL32)
Comprehensive installation guide for Reznor CL31 and CL32 relay kits, enabling multiple unit control for various Reznor electric and gas-fired heaters. Includes component lists, detailed installation steps, and wiring specifications.
Preview Reznor Vertical Louver Kit Installation Guide for Gas-Fired Unit Heaters (OPT-CD1)
Installation instructions for the Reznor OPT-CD1 Vertical Louver Kit, designed for gas-fired unit heaters (models UBX, UBXC, UBZ, UDX, UDXC, UDZ, UEZ). Includes component list and step-by-step assembly guide.
Preview Reznor UBXC/UDXC Gas-Fired Unit Heater Replacement Parts Manual
This manual provides detailed replacement parts information for Reznor UBXC and UDXC series gas-fired unit heaters. It includes sections on serial number decoding, electrical components, fan and motor assemblies, blower assemblies, cabinet components, heat exchanger and burner assemblies, venter and flue wrapper components, and various accessories and options.
Preview Reznor Heat Exchanger Gasket Kit Installation Guide for Gas-Fired Unit Heaters
Detailed installation instructions for Reznor heat exchanger gasket kits for UBX, UBXC, UBZ, UDX, UDXC, and UDZ gas-fired unit heaters. Includes kit components, sizes, and step-by-step installation procedures.