Anern AN-SCI-EVO-2000

Anern Hybrid Solar Inverter User Manual

Model: AN-SCI-EVO-2000

1. Introduction

This manual provides essential information for the safe and efficient operation of your Anern AN-SCI-EVO Hybrid Solar Inverter. Please read this manual thoroughly before installation and use, and keep it for future reference.

The Anern AN-SCI-EVO is a high-frequency, grid-connected hybrid inverter designed to integrate solar power with your electrical grid. It can operate without batteries but is compatible with lead-acid, gel, and lithium battery types. Its comprehensive LCD display allows for easy configuration of various functions, including battery charging current, AC/solar charger priority, and input voltage settings.

2. Safety Information

Important Safety Instructions:

3. Product Features

Anern Hybrid Solar Inverter AN-SCI-EVO-2000 front view

Figure 3.1: Front view of the Anern AN-SCI-EVO-2000 Hybrid Solar Inverter, showing the LCD display and control buttons.

4. Package Contents

Upon unpacking, please verify that all items are included and undamaged:

5. Installation and Setup

Proper installation is crucial for the safe and efficient operation of the inverter. It is recommended that installation be performed by a certified electrician.

5.1 Site Selection

5.2 Wiring Connections

Before making any connections, ensure all power sources (PV array, battery, AC grid) are disconnected and secured against accidental re-connection.

  1. Battery Connection: Connect the battery bank to the inverter's battery terminals. Ensure correct polarity (+ to + and - to -). The inverter requires a battery connection to operate.
  2. PV Array Connection: Connect the solar panel array to the inverter's PV input terminals. Observe correct polarity and ensure the PV input voltage is within the specified MPPT range (30-400 VDC) and does not exceed the maximum PV VOC (400 VDC). Recommended PV cable size is 16 AWG.
  3. AC Output Connection: Connect your household loads or distribution panel to the inverter's AC output terminals.
  4. AC Input Connection (Grid/Generator): If connecting to the utility grid or a generator, connect it to the inverter's AC input terminals.
  5. Grounding: Ensure the inverter is properly grounded according to local electrical codes.
Diagram showing connection options for Anern Hybrid Solar Inverter including solar panels, battery, utility, and household appliances.

Figure 5.1: System connection diagram illustrating various power sources and loads for the hybrid inverter.

5.3 WiFi Module Installation

The included WiFi module allows for remote monitoring. Connect the module to the designated communication port on the inverter. Follow the instructions provided with the WiFi module for network configuration and app setup.

Diagram showing WiFi monitoring setup for Anern Hybrid Solar Inverter and various protection features.

Figure 5.2: Overview of inverter protection features and WiFi monitoring capability.

6. Operating Instructions

6.1 Initial Power-Up

  1. After all connections are secure, switch on the battery breaker.
  2. Switch on the PV array breaker.
  3. Switch on the AC input breaker (if connected to grid/generator).
  4. The inverter will power on, and the LCD display will illuminate.

6.2 LCD Display and Settings

The LCD display provides real-time system information and allows for configuration of various parameters. Use the buttons below the display to navigate menus and adjust settings.

6.3 Operating Modes

The inverter supports multiple charging and output modes to meet diverse user requirements:

Diagram illustrating three charging modes for the Anern Hybrid Solar Inverter: Solar Priority, Solar + Utility, and Battery Only.

Figure 6.1: Available charging modes for the hybrid solar inverter.

6.4 Remote Monitoring

Once the WiFi module is configured, you can monitor the inverter's performance and adjust settings remotely via a mobile application. This allows for real-time data access and control.

7. Maintenance

Regular maintenance ensures the longevity and optimal performance of your inverter.

8. Troubleshooting

This section provides solutions to common issues. If the problem persists, contact customer support.

ProblemPossible CauseSolution
Inverter does not power on.No battery connection or low battery voltage.Ensure battery is connected and charged. The inverter requires a battery to operate.
No AC output.Overload, short circuit, or internal fault.Reduce load. Check for short circuits in wiring. Restart inverter. If fault persists, contact support.
Inverter reports an error when load is connected.Load exceeds inverter capacity, or specific load type incompatibility.Ensure total load does not exceed 2000W. Some inductive loads (e.g., motors, refrigerators) have high startup currents; ensure the inverter's surge capacity (2000W) is sufficient. Try connecting a smaller, resistive load to test.
PV input not detected or low.Insufficient sunlight, incorrect PV wiring, or PV voltage outside MPPT range.Check solar panel connections and ensure adequate sunlight. Verify PV voltage is within 30-400 VDC.
Overheating warning.Poor ventilation or excessive ambient temperature.Ensure adequate clearance around the inverter. Clean ventilation openings. Reduce ambient temperature if possible.

9. Specifications

ParameterValue
ModelAN-SCI-EVO-2000 (ECO-2000)
Max. PV Input Power2000 W
PV Voltage Range30-400 V DC
Max. PV VOC (Open Circuit Voltage)400 V DC
Startup Voltage>130 V
Recommended PV Cable Size16 AWG
Max. Charging Current80A
Nominal Input Frequency50/60 Hz
Output Power2000 W
Surge Capacity2000 W
Dimensions (L x W x H)45.5 x 35.5 x 20 cm
Weight6 kg

10. Warranty and Support

Warranty: Anern provides a 3-year warranty for this inverter. Please retain your proof of purchase for warranty claims.

Return Policy: A 30-day, uncomplicated return policy is offered.

Customer Support: For technical assistance, troubleshooting, or to obtain a German language manual, please contact Anern customer service through the platform where you purchased the product.