Introduction
This manual provides comprehensive instructions for the installation, operation, maintenance, and troubleshooting of your Phillips MX7052 PCD-360 Digital Deadbolt. Please read this manual thoroughly before installation and use to ensure proper function and security.

Figure 1: Phillips MX7052 PCD-360 Digital Deadbolt (Front View)
This image displays the front view of the Phillips MX7052 PCD-360 Digital Deadbolt, featuring the illuminated numeric keypad and the central key cylinder. The deadbolt has a satin nickel finish.
Setup and Installation
The Phillips MX7052 PCD-360 Digital Deadbolt is designed for surface-mount installation on interior wood or metal doors. It is compatible with both left and right-opening doors. Basic tools are required for installation.
Components Included:
- Digital Deadbolt Unit (Exterior Keypad)
- Interior Mechanism with Thumb Turn
- Mounting Plate (Screw-on or Weldable)
- Mounting Screws
- Instruction Manual (this document)
- Keys (for manual override)
Note: 4 AA batteries are required and are not included with the product. The deadbolt does not require an electrical connection.
Installation Steps:
- Prepare the Door: Ensure the door surface is clean and free of obstructions. This deadbolt is a surface-mount type.
- Install the Mounting Plate: Secure the interior mounting plate to the door. This plate can be screwed or welded into place depending on the door material and desired security.
- Install the Exterior Keypad: Position the exterior digital keypad unit on the outside of the door, aligning it with the mounting plate.
- Install the Interior Mechanism: Attach the interior mechanism, which includes the thumb turn, to the inside of the door, connecting it to the exterior unit and the mounting plate.
- Secure the Units: Use the provided screws to firmly secure both the exterior and interior units to the door.
- Insert Batteries: Open the battery compartment on the interior unit and insert 4 AA batteries (not included), ensuring correct polarity.
- Test Functionality: After installation, test the deadbolt's operation using both the keypad and the interior thumb turn before closing the door completely.

Figure 2: Phillips MX7052 PCD-360 Digital Deadbolt (Interior View)
This image shows the interior mechanism of the Phillips MX7052 PCD-360 Digital Deadbolt, featuring the thumb turn for manual locking and unlocking from the inside, and the battery compartment.
Operating Instructions
The Phillips MX7052 PCD-360 Digital Deadbolt offers multiple ways to lock and unlock your door.
Unlocking the Door:
- Using the Keypad: Enter your 4 to 8-digit user code on the exterior numeric keypad. The deadbolt will unlock, and the light indicator will confirm. The keypad supports up to 50 unique user codes.
- Using the Key: Insert the physical key into the key cylinder on the exterior unit and turn to unlock.
- From the Interior: Turn the thumb turn on the interior mechanism to unlock the deadbolt.
Locking the Door:
- From the Exterior: Press any key on the keypad or simply close the door (if auto-lock is enabled, refer to programming section for details). The light indicator will confirm locking.
- From the Interior: Turn the thumb turn on the interior mechanism to lock the deadbolt.
Light Indicator:
The light indicator on the exterior keypad provides visual feedback:
- Green Light: Indicates successful locking or unlocking.
- Red Light: Indicates an incorrect code entry or a system error.
Programming User Codes:
Refer to the detailed programming section in the full manual for instructions on adding, deleting, or modifying user codes. The deadbolt supports codes ranging from 4 to 8 digits and can store up to 50 unique user codes.

Figure 3: Phillips MX7052 PCD-360 Digital Deadbolt (Keypad Detail)
This image highlights the numeric keypad of the Phillips MX7052 PCD-360 Digital Deadbolt, used for entering access codes. The numbers are clearly visible and illuminated.
Maintenance
Battery Replacement:
The deadbolt requires 4 AA batteries. When the batteries are low, the light indicator may flash or the keypad may become unresponsive. To replace:
- Locate the battery compartment on the interior unit (refer to Figure 2).
- Remove the cover.
- Replace all four AA batteries with new ones, ensuring correct polarity.
- Replace the cover.
- Test the deadbolt's operation.
Cleaning:
Clean the exterior keypad and interior unit with a soft, damp cloth. Avoid abrasive cleaners or solvents, as these can damage the finish or electronic components.
Troubleshooting
- Deadbolt does not respond: Check battery level. Replace batteries if necessary. Ensure the keypad is clean and free of debris.
- Incorrect code entered: The light indicator will typically flash red. Re-enter the correct code carefully. If the issue persists, verify the programmed codes.
- Deadbolt is stiff or difficult to operate: Check for any obstructions around the door frame or latch. Ensure the deadbolt is properly aligned.
- Light indicator shows error: Refer to the full product manual for specific error code interpretations, if available. Generally, a red light indicates an issue.
If problems persist after attempting these troubleshooting steps, contact Phillips customer support.
Specifications
| Manufacturer | Phillips |
| Model Number | MX7052 |
| Product Name | PCD-360 Digital Deadbolt |
| Color | Satin Nickel |
| Material | Nickel |
| Lock Type | Deadbolt |
| Power Source | 4 AA Batteries (not included) |
| User Codes | 4 to 8 digits, up to 50 users |
| Dimensions (L x W x H) | 21.01 x 11 x 23.01 cm (8.27 x 4.33 x 9.06 inches) |
| Weight | 1.12 kg (2.47 lbs) |
| Recommended Use | Residential or commercial interior doors |
Warranty and Support
For information regarding the product warranty, please refer to the documentation included with your purchase or visit the official Phillips website. For technical support or further assistance, please contact Phillips customer service directly.