1. Introduction

Thank you for choosing the Paulmann 71076 Selection Bathroom Luena Wall Lamp. This manual provides important information regarding the installation, operation, and maintenance of your new wall lamp. Please read these instructions carefully before installation and keep them for future reference. This product is designed for indoor use, specifically in bathrooms and other damp areas, thanks to its IP44 splash water protection rating.

2. Safety Instructions

  • Electrical Safety: Installation must be carried out by a qualified electrician in accordance with local wiring regulations. Ensure the main power supply is switched off before commencing any installation or maintenance work.
  • Voltage: This lamp operates on 230V AC.
  • Bulb Type: Use only E14 bulbs with a maximum wattage of 20W. Do not exceed the specified wattage.
  • IP44 Rating: This product is splash-proof (IP44) and suitable for use in bathroom zones 2 and 3. Do not install in zone 1 (inside the shower or bath).
  • Handling: Handle glass components with care to prevent breakage.
  • Cleaning: Disconnect power before cleaning. Use a soft, dry cloth. Do not use abrasive cleaners or solvents.
Diagram illustrating IP protection zones in a bathroom, showing IP44, IP65, and IP67 areas

Figure 2.1: IP Protection Zones in a Bathroom. The Paulmann 71076 lamp is suitable for IP44 zones.

3. Package Contents

Please check that all components are present and undamaged before installation:

  • Paulmann 71076 Selection Bathroom Luena Wall Lamp fixture
  • Mounting instructions
  • Mounting hardware (screws, wall plugs)

Note: The light bulb (E14, max. 20W) is not included and must be purchased separately.

4. Setup and Installation

Follow these steps for proper installation:

  1. Prepare the Installation Site: Ensure the power supply to the installation area is switched off at the main circuit breaker.
  2. Mark Drilling Points: Hold the lamp's mounting plate against the wall at the desired installation height and mark the drilling points.
  3. Drill Holes: Drill holes at the marked points and insert appropriate wall plugs.
  4. Connect Wiring: Connect the lamp's wires to the 230V wall outlet wiring. Ensure correct polarity (Live, Neutral, Earth). Secure connections properly.
  5. Mount the Fixture: Attach the lamp's mounting plate to the wall using the provided screws.
  6. Install the Bulb: Carefully screw an E14 bulb (max. 20W) into the lamp holder.
  7. Attach Glass Shade: The bayonet glass shade can be attached and removed without tools. Align the glass shade with the fixture and twist to secure it.
  8. Restore Power: Once installation is complete and all components are securely in place, restore power at the main circuit breaker.
Close-up of the Paulmann Luena Wall Lamp's chrome base and glass shade

Figure 4.1: Close-up of the lamp's chrome base and glass shade, showing mounting points.

Dimensions of the Paulmann Luena Wall Lamp: 220mm height, 125mm depth, 100mm width

Figure 4.2: Product dimensions for installation planning.

5. Operating Instructions

Once installed and powered, the Paulmann 71076 wall lamp operates via your standard wall switch. If a dimmable E14 bulb is used and connected to a compatible dimmer switch, the light intensity can be adjusted. The lamp provides decorative light effects, enhancing the ambiance of your bathroom.

Paulmann Luena Wall Lamp with E14 socket, bulb not included

Figure 5.1: The E14 bulb socket, ready for bulb insertion.

Paulmann Luena Wall Lamp mounted on a wall, showcasing its modern design

Figure 5.2: The Paulmann Luena Wall Lamp in an installed setting.

6. Maintenance

To ensure the longevity and appearance of your Paulmann wall lamp, follow these maintenance guidelines:

  • Cleaning: Always switch off the power supply before cleaning. Use a soft, dry, or slightly damp cloth to wipe the chrome finish and glass shade. Avoid harsh chemicals, abrasive cleaners, or scouring pads, as these can damage the surfaces.
  • Bulb Replacement: Ensure the power is off and the bulb has cooled down before attempting to replace it. The bayonet glass shade can be easily removed without tools to access the E14 bulb.
  • Inspection: Periodically check the lamp for any signs of damage or loose connections. If any issues are found, disconnect power and consult a qualified electrician.
Paulmann Luena Wall Lamp with IP44 rating and tool-free removable glass

Figure 6.1: The bayonet glass shade can be removed without tools for easy bulb replacement and cleaning.

7. Troubleshooting

If you encounter issues with your Paulmann 71076 wall lamp, consider the following:

  • Lamp does not light up:
    • Check if the power supply is switched on at the wall switch and the main circuit breaker.
    • Ensure the bulb is correctly screwed in and not faulty. Try replacing the bulb with a new one.
    • Verify that the wiring connections are secure. If unsure, consult a qualified electrician.
  • Light flickers:
    • Ensure the bulb is fully tightened.
    • If using a dimmable bulb, ensure it is compatible with your dimmer switch.
    • Check for loose wiring connections.
  • Glass shade is loose:
    • Ensure the bayonet glass shade is properly aligned and twisted into its locked position.

If problems persist, contact Paulmann customer support or a qualified electrician.

8. Specifications

FeatureSpecification
Model Number71076
BrandPaulmann
Product Dimensions12.5 cm (L) x 10 cm (W) x 22 cm (H)
Item Weight850 Grams
MaterialGlass, Chrome
ColorChrome, Glass
FinishChrome
StyleModern/Minimalist
Room TypeBathroom
Specific UseBathroom
Indoor/Outdoor UseIndoor
Power SourceAC
Voltage230V
Bulb TypeE14 (not included)
Max. Wattage20W
DimmableYes (with compatible bulb and dimmer)
IP RatingIP44 (Splash-proof)
CertificationsCE
Batteries RequiredNo

9. Warranty and Support

Paulmann products are manufactured to high-quality standards and come with a manufacturer's warranty. For specific warranty terms and conditions, please refer to the documentation provided with your purchase or visit the official Paulmann website. For technical support, spare parts, or any questions not covered in this manual, please contact Paulmann customer service directly.

Related Documents - 71076

Preview Paulmann URail Track Spot Installation Guide - Model 976.13
Detailed installation instructions and safety information for the Paulmann URail track spot lighting system, model 976.13. Learn how to assemble and install your track lighting.
Preview Paulmann Lanka Spot Light Installation Guide
Comprehensive installation instructions and safety guidelines for the Paulmann Lanka spot light fixture (Article No. 667.69). Covers electrical connections, component replaceability, and technical specifications for safe and proper use.
Preview Paulmann Lillesol Solar LED Table Lamp Installation and Operation Guide
This guide provides instructions for the Paulmann Lillesol Solar LED Table Lamp (Art.-Nr.: 943.09), detailing its IP44 rating, rechargeable Li-Ion battery, and 3-step dimming functionality for optimal use.
Preview Paulmann Spaceglow Four Ceiling Lamp Installation and Operation Guide
Comprehensive guide for installing and operating the Paulmann Spaceglow Four ceiling lamp (Model 710.39). Includes safety instructions, wiring, remote control functions, component replaceability, and conformity information.
Preview Paulmann Sorova Solar LED Wall Luminaire with Motion Detector - Installation Guide
Installation and operation guide for the Paulmann Sorova Solar LED Wall Luminaire (Model 948.56). Features IP44 rating, motion detection, solar power, and rechargeable battery. Includes mounting, battery replacement, and settings details.
Preview Paulmann Casca LED Luminaire Installation Guide and Features
Comprehensive installation guide for the Paulmann Casca LED luminaire, detailing setup, wiring, color temperature control, dimming, and energy efficiency information. Includes model numbers 789.46, 789.47, 930.24, 930.25.