YuqiaoTime GC-01

FNIRSI GC-01 Nuclear Radiation Detector User Manual

Model: GC-01

Brand: YuqiaoTime

1. Product Overview

The FNIRSI GC-01 is a portable nuclear radiation detector designed to measure the intensity of ionizing radiation, including beta particles, gamma rays, and X-rays. It utilizes a high-precision Geiger-Müller counter tube to provide accurate readings for personal dosimetry and environmental monitoring. This device is suitable for detecting radiation in various environments, including industrial settings, food, metal, ceramic tiles, and marble.

Key Features

  • High-precision Geiger-Müller counter for accurate detection.
  • Detects beta particles, gamma rays, and X-rays.
  • Adjustable alarm thresholds with sound, glitter (visual), and vibrate modes.
  • Real-time, average, and cumulative dose equivalent rate display.
  • Built-in 1100mAh lithium battery for extended operation.
FNIRSI GC-01 Nuclear Radiation Detector with display showing readings and features like sound, glitter, vibrate, Geiger counter meter, I-131/CT, 1100mAh, industrial, food/metal, ceramic tile/marble, beta, gamma, X-ray, trend graph.
Figure 1: FNIRSI GC-01 Nuclear Radiation Detector. This image displays the FNIRSI GC-01 Nuclear Radiation Detector, highlighting its main features and display interface. It shows the device's ability to detect various radiation types and its alarm modes.

2. Safety Information

Always handle the device with care. Do not attempt to open or modify the device, as this may compromise its accuracy and safety features. Keep the device away from extreme temperatures, moisture, and strong electromagnetic fields. This device is intended for informational purposes and should not be used as the sole basis for critical safety decisions without professional consultation.

Table showing Nuclear Radiation Dose Hazards at a Glance, detailing the harm of different radiation doses to the human body, from 5-20 Rum to 1K-5K Rum.
Figure 2: Nuclear Radiation Dose Hazards. This table provides a quick reference to the potential health hazards associated with different levels of nuclear radiation exposure, ranging from delayed reactions to acute death.

3. Package Contents

Verify that all items are present in the package upon unboxing:

  • FNIRSI GC-01 Nuclear Radiation Detector
  • Type-C Charging Cable
  • User Manual
Table of product parameters for the FNIRSI GC-01 Nuclear Radiation Detector, including types of detection rays, detector type, dose equivalent rate, cumulative dose equivalent, energy range, language, sensitivity, dosage unit, power supply, alarm method, and size. Also shows the device, manual, and charging cable.
Figure 3: Product Parameters and Package Contents. This image presents a detailed table of the FNIRSI GC-01's technical specifications and lists the items included in the product package, such as the device, user manual, and Type-C charging cable.

4. Device Layout

The FNIRSI GC-01 features a clear display screen and intuitive button controls for easy operation. The main screen displays real-time radiation readings, average values, and cumulative dose. Navigation buttons allow access to settings and different measurement modes.

FNIRSI GC-01 detector screen showing settings for alarm value, unit, system clock, alarm mode, and display settings, with buttons for navigation and confirmation.
Figure 4: Device Interface and Alarm Settings. This image shows the user interface for setting alarm values on the FNIRSI GC-01, allowing users to configure thresholds for automatic alarms and select between sound, glitter, and vibrate alarm modes.

5. Setup

5.1 Charging the Device

Before first use, fully charge the device using the provided Type-C charging cable. Connect the cable to the device's charging port and a standard USB power adapter (not included). The charging indicator on the screen will show the charging status.

5.2 Powering On/Off

  • To Power On: Press and hold the power button (usually the 'OK' button) until the screen illuminates.
  • To Power Off: Press and hold the power button until the device shuts down.

5.3 Initial Settings

Upon first power-on or after a factory reset, you may need to configure basic settings:

  1. Navigate to the 'Settings' menu using the navigation buttons.
  2. Select 'Language' to choose your preferred language (e.g., English).
  3. Select 'Unit' to set the desired measurement unit (e.g., uSv/h, mR/h).
  4. Adjust the 'System Clock' to ensure accurate timekeeping for data logging.

6. Operating Instructions

6.1 Measurement Modes

The device typically operates in a continuous measurement mode, displaying:

  • Current Dose Rate: Real-time radiation level.
  • Average Dose Rate: Average radiation level over a period.
  • Cumulative Dose: Total accumulated radiation dose since the last reset.

The device automatically detects beta, gamma, and X-rays. Its GM Geiger Counter Tube offers high precision for accurate readings.

Comparison chart illustrating the higher precision of the GC-01 Nuclear Radiation Detector's GM Geiger Counter Tube compared to an ordinary counter tube, showing measuring range, basic error, response time, and measurable rays.
Figure 5: GM Geiger Counter Tube Precision. This chart compares the performance of the GC-01's Geiger-Müller tube with a standard counter tube, demonstrating its superior measuring range, lower basic error, faster response time, and broader detection capabilities for X, Y, and hard Beta rays.

6.2 Setting Alarm Values

To set a custom alarm threshold:

  1. Access the 'Set Alarm' option in the menu.
  2. Use the navigation buttons to adjust the 'Current Alarm' value (dose rate threshold).
  3. Adjust the 'Cumulative Alarm' value (total dose threshold) if desired.
  4. Confirm your settings. The device will trigger an alarm if the measured radiation exceeds these set values.

6.3 Alarm Modes

The FNIRSI GC-01 offers three distinct alarm modes:

  • Sound: An audible alert will be emitted.
  • Glitter: The screen will flash or a visual indicator will activate.
  • Vibrate: The device will vibrate to alert the user.

These modes can be configured in the 'Ala Mode' setting within the menu.

7. Maintenance

7.1 Cleaning

Wipe the device with a soft, dry cloth. Do not use abrasive cleaners, solvents, or immerse the device in water. Ensure the charging port is free from dust and debris.

7.2 Storage

Store the device in a cool, dry place away from direct sunlight and extreme temperatures. If storing for an extended period, ensure the battery is partially charged (around 50%) to prolong its lifespan.

7.3 Battery Care

To maintain battery health, avoid fully discharging the device frequently. Recharge the battery when the low battery indicator appears. Use only the provided Type-C cable for charging.

8. Troubleshooting

8.1 Device Does Not Power On

  • Ensure the battery is charged. Connect the device to a power source using the Type-C cable and try again.
  • Press and hold the power button for at least 5 seconds.

8.2 Inaccurate Readings

  • Ensure the device is not near strong electromagnetic interference sources.
  • Verify that the measurement unit is correctly set in the device settings.
  • If readings are consistently abnormal, contact customer support.

8.3 Alarm Not Functioning

  • Check the 'Set Alarm' values to ensure they are configured correctly and are not too high.
  • Verify that the desired 'Ala Mode' (Sound, Glitter, Vibrate) is enabled in the settings.

9. Specifications

ParameterValue
Types of Detection RaysGamma rays, X-rays, Beta rays
DetectorEnergy Compensation GM Tube (Geiger Tech no logy Tube)
Dose Equivalent Rate0.00-100000 μSv/h (10mSv/h)
Cumulative Dose Equivalent0.00 μSv-500.0mSv
Energy Range48keV-1.5MeV ±30% (for 137CS-)
LanguageChinese/English switch
Sensitivity80CPM/pSv (For Co-60)
Dosage UnitnSv/h, pSv/h, mR/h, cps, cpm Switch
Power Supply1100mAh lithium battery
Alarm MethodLight, vibration, sound
Product Dimensions (L x W x H)120 x 78 x 27 mm
Product Weight500 grams
Measurement Precision±0.1%
CertificationsRoHS, CE
MaterialAcrylonitrile Butadiene Styrene

10. Warranty and Support

The manufacturer provides a commitment to spare parts availability for 5 years from the date of purchase. For technical support, warranty claims, or service inquiries, please refer to the contact information provided with your purchase documentation or visit the official YuqiaoTime website.

Related Documents - GC-01

Preview FNIRSI GC-02 Radiation Detector and Dosimeter User Manual
This user manual provides a comprehensive guide to the FNIRSI GC-02 radiation detector and dosimeter, covering its features, specifications, operation, settings, and maintenance. Learn how to use this device for accurate detection of ionizing radiation.
Preview FNIRSI GC-02 Nuclear Radiation Detector User Manual
User manual for the FNIRSI GC-02 nuclear radiation detector, detailing its features, operation, and specifications for accurate radiation measurement.
Preview FNIRSI GC-01 Nuclear Radiation Detector User Manual
User manual for the FNIRSI GC-01 Nuclear Radiation Detector, detailing its features, operation, specifications, and maintenance. Learn how to use this Geiger-Miller counter for detecting ionizing radiation.
Preview FNIRSI GC-01 Nuclear Radiation Detector User Manual
User manual for the FNIRSI GC-01 Nuclear Radiation Detector, covering product description, key features, parameters, operation, maintenance, and conversion of radioactive units.
Preview FNIRSI GC-01 Nuclear Radiation Detector User Manual
User manual for the FNIRSI GC-01 Nuclear Radiation Detector, covering product overview, features, specifications, operation, radiation knowledge, precautions, maintenance, and manufacturing information.
Preview FNIRSI GC-01 Nuclear Radiation Detector User Manual
User manual for the FNIRSI GC-01 Nuclear Radiation Detector, covering product description, key features, parameters, operation, unit conversion, notes, maintenance, and production information.