1. Introduction
This manual provides essential information for the safe and effective use of your Parkside High-Pressure Cleaner Lance. Please read these instructions carefully before use and retain them for future reference. This lance is designed as an accessory for specific Parkside LIDL high-pressure cleaner models.
Compatible Models:
- Parkside LIDL PHD 150 G4 (IAN 305729)
- Parkside LIDL PHD 150 F4 (IAN 291639)
- Parkside LIDL PHD 170 A1 (IAN 327191)
- Parkside LIDL PHD 170 B2 (IAN 346400, IAN 378872, IAN 373932)
- Parkside LIDL PHD 170 C2 (IAN 373767)
2. Safety Information
Always observe general safety precautions when operating high-pressure cleaning equipment. Failure to do so can result in serious injury or property damage.
- Read the main high-pressure cleaner manual: Always refer to the instruction manual of your specific Parkside high-pressure cleaner for comprehensive safety guidelines.
- Wear protective gear: Always wear appropriate personal protective equipment, including safety glasses and protective clothing, to prevent injury from high-pressure spray.
- Do not direct spray at people or animals: The high-pressure jet can cause severe injuries.
- Check connections: Ensure all connections are secure before operating the high-pressure cleaner.
- Inspect for damage: Before each use, inspect the lance for any signs of damage. Do not use if damaged.
- Keep children away: Do not allow children or untrained persons to operate the high-pressure cleaner or its accessories.
3. Package Contents
Upon unpacking, ensure all items are present and undamaged. The package typically includes:
- 1 x Parkside High-Pressure Lance

Image: The Parkside high-pressure cleaner lance, a black ribbed accessory with a quick-connect fitting at one end, designed for high-pressure cleaning tasks.
4. Setup
Follow these steps to correctly attach the high-pressure lance to your Parkside high-pressure cleaner:
- Ensure power is off: Before connecting or disconnecting any accessories, ensure your high-pressure cleaner is switched off and unplugged from the power supply.
- Connect to spray gun: Insert the quick-connect end of the high-pressure lance into the spray gun of your high-pressure cleaner. Push firmly until it clicks into place, indicating a secure connection.
- Attach nozzle (if applicable): This lance is designed for easy nozzle change using the Quick Connect system. If you are using a separate Turbo dirt blaster or standard Vario nozzle, attach it to the end of the lance by pushing it in until it locks.
- Check for leaks: Once connected, turn on the water supply to the high-pressure cleaner and check for any leaks before starting the machine.
5. Operating
Once the lance is securely attached and the high-pressure cleaner is ready for operation, follow these general guidelines:
- Start the high-pressure cleaner: Follow the instructions in your main high-pressure cleaner manual to start the machine.
- Engage the trigger: Point the lance away from yourself and others, then press the trigger on the spray gun to begin spraying.
- Maintain distance: Adjust the distance between the nozzle and the cleaning surface based on the material and desired cleaning intensity. Start further away and move closer if needed.
- Even strokes: Use even, overlapping strokes to ensure thorough cleaning.
- Stop operation: Release the trigger to stop the water flow. Always turn off the high-pressure cleaner and relieve pressure before disconnecting the lance or changing nozzles.
6. Maintenance
Proper maintenance ensures the longevity and optimal performance of your high-pressure cleaner lance:
- Rinse after use: After each use, rinse the lance thoroughly with clean water to remove any detergent residues or debris.
- Inspect for blockages: Periodically check the nozzle and lance for any blockages. Clear them carefully if found.
- Lubricate O-rings: If the quick-connect fitting becomes stiff, apply a small amount of silicone grease to the O-rings to maintain a smooth connection and prevent leaks.
- Storage: Store the lance in a clean, dry place, protected from frost and direct sunlight.
- Avoid harsh chemicals: Do not use abrasive cleaners or solvents on the lance, as these can damage the material.
7. Troubleshooting
If you encounter issues with your high-pressure cleaner lance, consider the following common problems and solutions:
| Problem | Possible Cause | Solution |
|---|---|---|
| Water leaking from connection | Loose connection, damaged O-ring, or debris in fitting. | Ensure lance is fully inserted and locked. Inspect O-rings for damage and replace if necessary. Clean fitting. |
| No water or low pressure from lance | Nozzle blockage, water supply issue, or problem with the main high-pressure cleaner. | Check and clear any nozzle blockages. Verify water supply to the cleaner. Refer to your high-pressure cleaner's manual for machine-related issues. |
| Lance difficult to attach/detach | Lack of lubrication on O-rings, or debris. | Clean the quick-connect fitting. Apply silicone grease to the O-rings. |
If problems persist, consult the main high-pressure cleaner manual or contact customer support.
8. Specifications
| Brand | Parkside |
| Model Number | PHD 170 (Accessory for various PHD 150/170 models) |
| Manufacturer | Grizzly Tools |
| Product Dimensions (L x W x H) | 20 x 10 x 5 cm |
| Material | Metal (Primary material for internal components, outer is likely plastic) |
| Number of Pieces | 1 |
| Certification | CE |
| ASIN | B0CB8WHD28 |
| International Article Code (EAN) | 04062495085579 |
9. Warranty and Support
For warranty information and customer support, please refer to the documentation provided with your main Parkside high-pressure cleaner unit or contact the manufacturer directly.
Spare Parts: Information regarding the availability of spare parts for this accessory is currently unavailable through standard product listings. Please contact Parkside customer service for further assistance.