1. Introduction
This manual provides detailed instructions for the safe and effective use of your Berrcom Value Bundle, which includes the Berrcom Digital Thermometer DT008 and the Berrcom Non-Contact Infrared Thermometer JXB178. Please read this manual thoroughly before using the devices and retain it for future reference.

Image 1.1: The Berrcom DT008 Digital Thermometer and JXB178 Non-Contact Infrared Thermometer included in the bundle.
2. Safety Information
- Do not attempt to disassemble or repair the thermometers yourself.
- Keep the devices out of reach of children and pets.
- Avoid exposing the thermometers to direct sunlight, extreme temperatures, or high humidity.
- Clean the thermometers according to the 'Maintenance' section to ensure hygiene and accuracy.
- Consult a medical professional for any health concerns or if you suspect a fever. The thermometer readings are for reference only.
3. Product Overview
3.1 Berrcom Digital Thermometer DT008
The DT008 is a versatile digital thermometer designed for accurate temperature measurement via oral, rectal, or armpit methods. It features a clear display, beeper alarm, memory function, and automatic shut-off.

Image 3.1: The Berrcom DT008 Digital Thermometer in its retail packaging.
3.2 Berrcom Non-Contact Infrared Thermometer JXB178
The JXB178 is a non-contact infrared thermometer for quick and hygienic temperature readings. It offers multiple measurement modes (Body, Surface, Room), a backlit display with color-coded fever indication, and memory storage.

Image 3.2: The Berrcom JXB178 Non-Contact Infrared Thermometer in its retail packaging.
4. Setup and Operation - Berrcom Digital Thermometer DT008
4.1 Battery Installation
The DT008 thermometer is battery-powered. To install or replace the battery, gently slide off the battery cover at the end of the thermometer. Insert the LR41 battery, ensuring correct polarity. Replace the cover securely.
4.2 Power On/Off
- Press the power button to turn the thermometer on. A short beep will sound, and the last measured temperature will display briefly, followed by 'Lo°F' or 'Lo°C'.
- The thermometer will automatically shut off after approximately 10 minutes of inactivity to conserve battery life.
4.3 Switching Temperature Units (°C/°F)
To switch between Fahrenheit (°F) and Celsius (°C):
- Ensure the thermometer is turned off.
- Press and hold the power button for 2-4 seconds until the unit changes.

Image 4.1: The DT008 display indicating the option to switch between Celsius and Fahrenheit.
4.4 Taking a Measurement
The DT008 can be used for oral, rectal, or armpit temperature measurement. Ensure the probe tip is clean before use.
- Oral Use: Place the probe tip under the tongue, close the mouth, and hold the thermometer in place.
- Rectal Use: Apply a water-soluble lubricant to the probe tip. Gently insert the tip into the rectum (approximately 0.5 inches for infants).
- Armpit (Axillary) Use: Place the probe tip in the armpit, ensuring good skin contact. Hold the arm firmly against the body.
The measurement is complete when a beeper sounds and the temperature reading stabilizes on the display. The measurement typically takes a few seconds. For accurate results, do not touch the probe with hands or other high-temperature objects before use.

Image 4.2: Illustrations of the DT008 Digital Thermometer being used for oral, rectal, and underarm temperature measurements.

Image 4.3: Key features of the DT008 Digital Thermometer.
5. Setup and Operation - Berrcom Non-Contact Infrared Thermometer JXB178
5.1 Battery Installation
The JXB178 thermometer requires batteries. Open the battery compartment cover, insert the batteries according to the polarity indicators, and close the cover securely.
5.2 Power On/Off
Press the measurement button to turn the thermometer on. It will perform a self-test and display the last reading before entering measurement mode. The device will automatically power off after a period of inactivity.
5.3 Switching Temperature Units (°C/°F)
The JXB178 allows switching between Celsius (°C) and Fahrenheit (°F) via a dedicated button or setting in the menu, typically labeled 'MODE' or 'SET'. Refer to the on-screen prompts for specific instructions.
5.4 Mode Selection
The JXB178 offers multiple measurement modes:
- Body Mode: For measuring human body temperature.
- Surface Mode: For measuring the temperature of objects or liquids.
- Room Mode: For measuring ambient room temperature.
Use the 'MODE' button to cycle through these options.

Image 5.1: The JXB178's 6-in-1 measurement modes and features.
5.5 Taking a Non-Contact Measurement
Ensure the thermometer is in 'Body Mode' for human temperature measurement.
- Point the thermometer at the center of the forehead from a distance of 1-2 inches (2.5-5 cm).
- Press the measurement button. The temperature will be displayed instantly.
- The backlight color indicates the temperature status:
- Green: Normal temperature (e.g., 89.6°F - 99.2°F)
- Orange: Slightly elevated temperature (e.g., 99.3°F - 100.3°F)
- Red: Fever (e.g., 100.4°F - 109.2°F)

Image 5.2: The JXB178's three-color backlight system for temperature indication.
5.6 Silent Mode
The JXB178 features a silent mode, allowing temperature readings without disruptive beeps, ideal for use when a baby is sleeping. Refer to the device's interface for activating/deactivating silent mode, typically indicated by a speaker icon.

Image 5.3: The JXB178 in use, demonstrating clear reading and silent operation.
6. Maintenance
6.1 Cleaning
Both thermometers should be wiped clean after each use. Use a soft cloth dampened with alcohol (70% isopropyl) or soap and water. Do not immerse the devices in water or use abrasive cleaners. Ensure the probe tip of the DT008 is thoroughly cleaned.
6.2 Storage
Store the thermometers in a cool, dry place, away from direct sunlight and extreme temperatures. The DT008 comes with a storage case for protection.
6.3 Battery Replacement
Replace batteries when the low battery indicator appears on the display. Dispose of used batteries responsibly according to local regulations.
7. Troubleshooting
Refer to the table below for common issues and their solutions:

Image 7.1: Troubleshooting guide for common thermometer issues.
| Error Icon | Problem | Solution |
|---|---|---|
| Lo | Temperature lower than 32°C (90°F) | Turn off and wait 1 minute, then take a new temperature. Ensure the tip has tight contact. |
| Hi | Temperature higher than 42°C (109°F) | Turn off and wait 1 minute, then take a new temperature. Ensure the person has sufficient rest. |
| Err | Functioning improperly | Remove the battery and wait 1 minute, then reinstall the battery and turn it on. Contact the retailer if it is still not working. |
| Battery Icon Flashing | Low Battery | Replace the battery. |
If problems persist after attempting these solutions, please contact the retailer or Berrcom customer support for assistance.
8. Specifications
- Brand: Berrcom
- Models: DT008, JXB178
- Special Feature: High Accuracy
- Age Range (Description): Adult (suitable for all ages including babies, children, adults)
- Outer Material: Plastic
- Display Type: Digital
- Connectivity Technology: Infrared (JXB178)
- Product Care Instructions: Wipe Clean
- Power Source: Battery Powered
- Certifications: ANSI, ASME, ASTM, CCC, CE, CSA, EMC, ETL, FCC, FDA, FE, HACCP, ISO 13485, ISO 9000, ISO 9001, NIST, NSF, RoHS, UL, WEEE
9. Warranty and Support
Berrcom is committed to providing quality healthcare products. While specific warranty details are not provided in this manual, Berrcom emphasizes a commitment to health protection. For any product-related issues or support, please contact your retailer or refer to the official Berrcom website for customer service information.
10. Package Contents
The Berrcom Value Bundle includes the following items:
- Berrcom Digital Thermometer DT008 x 1
- Berrcom Non-Contact Infrared Forehead Thermometer JXB178 x 1
- LR41 Batteries (for DT008) x 1
- Storage Case (for DT008) x 1
- Instruction Manual x 1

Image 10.1: Contents of the Berrcom Digital Thermometer DT008 package.