1. Introduction
This manual provides essential information for the safe and efficient operation of your Argo Odin Plus Portable Air Conditioner, Model OdinPlus-12K. This unit offers powerful cooling and heating capabilities, along with dehumidification and fan functions, designed for rooms up to 30 m².
Key features include:
- Powerful 13,000 BTU cooling and 10,500 BTU heating capacity.
- Five operating modes: Cool, Heat, Fan, Dehumidification, and Sleep.
- Integrated Wi-Fi for app and voice assistant control.
- 24-hour timer for scheduled operation.
- Automatic oscillating air vents for even air distribution.
- Automatic restart function and self-diagnosis with error code display.
- Quiet sleep mode for reduced noise during nighttime use.
2. Safety Information
Please read all safety instructions carefully before operating the appliance. Failure to follow these instructions may result in electric shock, fire, or personal injury.
- Ensure the power supply matches the unit's requirements (220-240V~/1/50Hz).
- Do not operate the unit with a damaged power cord or plug.
- Keep the unit upright during transport and operation to prevent refrigerant leakage.
- Do not block air inlets or outlets. Maintain adequate clearance around the unit.
- Do not insert objects into the air outlets.
- Unplug the unit before cleaning or performing any maintenance.
- This appliance is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety.
- Children should be supervised to ensure that they do not play with the appliance.
- The appliance contains R290 refrigerant. Do not puncture the refrigerant circuit.
3. Product Overview
Familiarize yourself with the components and control panel of your Argo Odin Plus unit.

Figure 3.1: Front and Side View of the Argo Odin Plus Portable Air Conditioner. This image displays the main body of the unit, showing the front panel with the air outlet and the side grille for air intake.

Figure 3.2: Top Control Panel of the Argo Odin Plus. This image shows the touch-sensitive control panel with various function buttons including ION, SWING, TIMER, SPEED, UP, DOWN, MODE, SLEEP, POWER, and WIFI indicators.

Figure 3.3: Rear View of the Argo Odin Plus Portable Air Conditioner. This image illustrates the back of the unit, featuring the exhaust air outlet, air intake grilles, and the drainage port.
3.1. Main Components
- Control Panel: Located on the top of the unit for manual operation.
- Air Outlet: Front-facing, with automatic oscillating louvers.
- Air Intake Grilles: Located on the sides and rear.
- Exhaust Air Outlet: Rear connection point for the exhaust hose.
- Drainage Port: For continuous drainage in dehumidification mode or manual drainage.
- Casters: For easy mobility of the unit.
4. Setup and Installation
Proper setup is crucial for optimal performance and safety.
4.1. Unpacking
- Carefully remove the unit from its packaging.
- Check for any damage during transit. Contact your retailer if damage is found.
- Retain the packaging for future storage or transport.
4.2. Positioning the Unit
- Place the air conditioner on a flat, stable surface.
- Ensure there is at least 30 cm (12 inches) of clearance around the unit for proper airflow.
- Position the unit near a window or door for exhaust hose installation.
4.3. Exhaust Hose Installation
The exhaust hose expels hot air outside, which is essential for cooling and heating efficiency.
- Attach one end of the exhaust hose (diameter 140-150 mm, length 1.5 m) to the exhaust air outlet on the rear of the unit.
- Extend the other end of the hose to a window or door opening.
- Use the provided window kit (if applicable) to seal the opening around the hose, minimizing air leakage.
- Ensure the exhaust hose is as straight and short as possible to maximize efficiency. Avoid sharp bends.
4.4. Power Connection
- Plug the power cord into a grounded electrical outlet (220-240V~/1/50Hz).
- Do not use extension cords or multi-plugs.
5. Operating Instructions
The Argo Odin Plus offers multiple operating modes for year-round comfort. Refer to Figure 3.2 for control panel layout.
5.1. Power On/Off
- Press the POWER button to turn the unit on or off.
5.2. Mode Selection
Press the MODE button to cycle through the available modes:
- Cool Mode: For cooling the room. Set desired temperature using UP and DOWN buttons.
- Heat Mode: For heating the room (via heat pump). Set desired temperature using UP and DOWN buttons.
- Fan Mode: Circulates air without cooling or heating. Adjust fan speed using the SPEED button.
- Dehumidification Mode: Reduces humidity in the room. The unit will operate at a fixed fan speed. Continuous drainage is recommended for this mode.
- Sleep Mode: Optimizes comfort and reduces noise during sleep. The unit will gradually adjust temperature and fan speed.
5.3. Fan Speed Adjustment
- Press the SPEED button to select fan speed (Low, Medium, High).
5.4. Timer Function
- Press the TIMER button to set a delayed start or stop time (up to 24 hours). Use UP and DOWN buttons to adjust the time.
5.5. Swing Function
- Press the SWING button to activate or deactivate the automatic oscillation of the air louvers.
5.6. Wi-Fi Connectivity
- The unit features integrated Wi-Fi for control via a smartphone app or voice assistant. Refer to the separate Wi-Fi setup guide for detailed instructions on connecting your device.
6. Maintenance
Regular maintenance ensures optimal performance and extends the lifespan of your air conditioner.
6.1. Cleaning the Air Filter
The Argo Odin Plus is equipped with a washable filter. A dirty filter can reduce efficiency and airflow.
- Unplug the unit from the power outlet.
- Locate and remove the air filter from the rear or side intake grille.
- Wash the filter gently with lukewarm water and a mild detergent.
- Rinse thoroughly and allow the filter to air dry completely before reinserting.
- Clean the filter every two weeks or more frequently depending on usage and air quality.
6.2. Draining Accumulated Water
The unit has an internal water collection tank. When full, the unit will stop operating and display a "POWER FULL" indicator (refer to Figure 3.2).
- Turn off and unplug the unit.
- Place a shallow pan or container under the drainage port at the rear of the unit.
- Remove the drain plug to allow water to flow out.
- Once drained, replace the drain plug securely.
- For continuous drainage (recommended for dehumidification mode), connect a drain hose (not included) to the drainage port and direct it to a floor drain.
6.3. Exterior Cleaning
- Wipe the exterior of the unit with a soft, damp cloth.
- Do not use harsh chemicals, abrasives, or solvents.
7. Troubleshooting
Before contacting customer support, refer to the following common issues and solutions. The unit's self-diagnosis feature may display error codes on the screen for easier problem identification.
| Problem | Possible Cause | Solution |
|---|---|---|
| Unit does not turn on. | No power supply; Power cord not plugged in; Fuse blown. | Check power connection; Check household fuse/circuit breaker. |
| Unit runs but does not cool/heat. | Exhaust hose not properly installed; Air filter dirty; Room too large; Doors/windows open. | Ensure exhaust hose is sealed; Clean air filter; Close doors/windows; Check unit capacity for room size. |
| "POWER FULL" indicator is on. | Water tank is full. | Drain the accumulated water from the unit. |
| Unit is noisy. | Unit not on a flat surface; Air filter dirty; Obstruction in fan. | Place on a flat surface; Clean air filter; Check for obstructions. |
| Wi-Fi connection issues. | Incorrect network settings; Router too far; App issues. | Refer to the Wi-Fi setup guide; Ensure unit is within router range; Restart app/unit. |
If the problem persists after attempting these solutions, please contact customer support.
8. Specifications
Technical specifications for the Argo Odin Plus Portable Air Conditioner.

Figure 8.1: Dimensions of the Argo Odin Plus Portable Air Conditioner. This diagram shows the height (770 mm), width (470 mm), and depth (382 mm) of the unit.

Figure 8.2: Energy Label for Argo Odin Plus. This label indicates the energy efficiency ratings (A/A for cooling/heating), EER (2.6), COP (2.5), power consumption, and sound power level (65 dB).
| Feature | Specification |
|---|---|
| Brand | Argo |
| Model Number | OdinPlus-12K |
| Cooling Capacity (Max) | 13,000 BTU / 3.5 kW |
| Heating Capacity (Max) | 10,500 BTU / 2.75 kW |
| Energy Efficiency Class (Cooling/Heating) | A / A |
| EER (Energy Efficiency Ratio) | 2.61 |
| COP (Coefficient of Performance) | 2.50 |
| Max Airflow | 400 m³/h |
| Dehumidification Capacity | 28 L/24h |
| Fan Speeds | 3 (Low, Medium, High) |
| Sound Power Level | 65 dB(A) |
| Power Supply | 220-240V~ / 1 Phase / 50Hz |
| Nominal Absorbed Power (Cooling/Heating) | 1.34 kW / 1.1 kW |
| Hourly Power Consumption (Cooling/Heating) | 1.3 kWh/60min / 1.1 kWh/60min |
| Standby Power Consumption | 1 W |
| Refrigerant Type | R290 |
| Refrigerant Charge | 0.29 kg |
| Flexible Hose Diameter (Inner-Outer) | 140-150 mm |
| Flexible Hose Length | 1.5 m |
| Net Weight | 31.5 kg |
| Dimensions (H x W x D) | 770 x 470 x 382 mm |
| Filter Type | Washable |
| Special Feature | Dehumidifier, Wi-Fi Connectivity |
9. Warranty and Support
For warranty information, please refer to the warranty card included with your product or visit the official Argo website. Keep your purchase receipt as proof of purchase.
For technical support, troubleshooting assistance beyond this manual, or spare parts inquiries, please contact Argo customer service. Contact details can typically be found on the manufacturer's website or in your product documentation.