Avalla
Avalla S-50 Portable Air Conditioner User Manual
Model: AVS-50
1. Important Safety Information
Please read this manual thoroughly before operating your Avalla S-50 Portable Air Conditioner. Keep this manual for future reference.
- Ensure the unit is placed on a stable, level surface to prevent tipping.
- Do not block air inlets or outlets. Maintain at least 30cm clearance around the unit.
- Only use the unit with a properly grounded electrical outlet.
- Do not operate the unit if the power cord or plug is damaged.
- Keep children and pets away from the unit during operation.
- This appliance uses R-290 refrigerant. Do not puncture the refrigerant circuit.
- Always unplug the unit before cleaning or performing any maintenance.
2. Product Overview
The Avalla S-50 is a versatile 4-in-1 portable air conditioning unit designed to provide comfort in medium-sized rooms up to 12m3.
Key Components:
- Portable Air Conditioner Unit
- Exhaust Hose
- Window Vent Kit (Window Bracket, Hose Connector)
- Remote Control

Figure 2.1: Avalla S-50 unit and included accessories.
4-in-1 Functionality:
- Air Conditioner: Provides powerful cooling, maintaining a comfortable temperature down to 150C.
- Dehumidifier: Extracts up to 7.2 litres of water per day, protecting your home from damp and mould.
- Fan: Circulates natural air, ensuring consistent indoor air movement.
- Sleep Mode: Operates quietly at 45dB for undisturbed rest, with a dimmable display.

Figure 2.2: Overview of the Avalla S-50's four operational modes.

Figure 2.3: Cooling performance in various room environments.
3. Setup and Installation
3.1 Unpacking and Initial Placement
- Carefully remove the unit and all accessories from the packaging.
- Place the unit upright on a flat, stable surface. It is recommended to let the unit stand upright for at least 2-4 hours before first use if it was transported horizontally.
- Ensure there is at least 30cm of space around the unit for proper airflow.
3.2 Window Vent Kit Installation
The window vent kit is essential for exhausting hot air outside, ensuring efficient cooling.
- Attach the hose connector to one end of the exhaust hose.
- Insert the other end of the exhaust hose into the exhaust port on the back of the air conditioner unit.
- Adjust the window bracket to fit your window opening. The kit is designed for various window types, including sliding, casement, awning, and sash windows.
- Secure the window bracket in the open window.
- Connect the hose connector (with the exhaust hose attached) to the opening in the window bracket.
- Close the window as much as possible to seal around the bracket and hose, minimizing air leakage.

Figure 3.1: Unit setup with window kit.
Video 3.1: Demonstrates the versatility of the Avalla portable air conditioners with various window types for exhaust hose installation.
3.3 Continuous Drainage Setup (Dehumidifier Mode)
For continuous dehumidification, you can connect a drainage hose (not included) to the continuous drainage port on the back of the unit.
- Locate the continuous drainage port on the lower rear of the unit.
- Connect a suitable drainage hose to this port.
- Direct the other end of the hose to a floor drain or a large container, ensuring the hose is sloped downwards for gravity drainage.

Figure 3.2: Setup for continuous water drainage.
4. Operating Instructions
4.1 Control Panel and Remote Control
The unit can be operated using the touch control panel on top of the unit or the included remote control. Both offer similar functionalities.
Control Panel Buttons:
- Power Button: Turns the unit On/Off.
- Mode Button: Cycles through Cooling, Dehumidifier, Fan, and Sleep modes.
- Temperature Up/Down Buttons: Adjusts the desired temperature in Cooling mode.
- Fan Speed Button: Selects fan speed (Low, Medium, High).
- Timer Button: Sets the auto On/Off timer.
- Sleep Button: Activates Sleep mode for quiet operation and dim display.
4.2 Operating Modes
Cooling Mode:
- Press the Power button to turn on the unit.
- Press the Mode button until the Cooling indicator light is on.
- Use the Temperature Up/Down buttons to set your desired temperature (150C - 300C).
- Adjust the Fan Speed as desired.
Dehumidifier Mode:
This mode helps reduce humidity in the room without significant cooling.
- Press the Power button to turn on the unit.
- Press the Mode button until the Dehumidifier indicator light is on.
- The unit will automatically operate to remove moisture. Ensure proper drainage is set up (continuous drainage recommended for this mode).

Figure 4.1: Dehumidifier mode for moisture removal.
Fan Mode:
Operates as a fan to circulate air without cooling or dehumidifying.
- Press the Power button to turn on the unit.
- Press the Mode button until the Fan indicator light is on.
- Adjust the Fan Speed as desired.
Sleep Mode:
Designed for quiet operation during sleep, with a dimmed display.
- Activate Cooling or Fan mode.
- Press the Sleep button. The display will dim, and the fan speed will automatically adjust to a lower, quieter setting.

Figure 4.2: Sleep mode for quiet night-time operation.
4.3 Timer Function
The timer allows you to set the unit to automatically turn On or Off after a set period (1-24 hours).
- To set Auto-Off: With the unit running, press the Timer button. Use the Temperature Up/Down buttons to select the desired hours until shutdown.
- To set Auto-On: With the unit off, press the Timer button. Use the Temperature Up/Down buttons to select the desired hours until startup.
- The timer indicator will light up when active. To cancel, press the Timer button again.
5. Maintenance
Regular maintenance ensures optimal performance and extends the lifespan of your air conditioner.
5.1 Cleaning the Air Filter
The air filter should be cleaned every two weeks or more frequently depending on usage and air quality.
- Unplug the air conditioner from the power outlet.
- Locate the air filter panel (usually on the back or side of the unit).
- Remove the filter.
- Clean the filter using a vacuum cleaner to remove dust, or wash it gently with warm water and mild detergent.
- Allow the filter to air dry completely before reinserting it into the unit. Do not expose to direct sunlight.
5.2 Draining the Internal Water Tank
The unit has an internal water tank that collects condensed moisture. When full, the unit will stop operating and display an indicator. Drain the tank as follows:
- Unplug the air conditioner.
- Place a shallow pan or bucket under the drainage port (usually at the bottom rear of the unit).
- Remove the drain plug/cap. Water will begin to flow out.
- Once all water has drained, replace the drain plug/cap securely.
5.3 Storage
When storing the unit for an extended period:
- Ensure the internal water tank is completely drained.
- Clean the air filter.
- Unplug the power cord and coil it neatly.
- Store the unit in a cool, dry place, preferably in its original packaging, away from direct sunlight and extreme temperatures.
6. Troubleshooting
Before contacting customer support, please refer to the following table for common issues and solutions:
| Problem | Possible Cause | Solution |
|---|---|---|
| Unit does not turn on. | No power, power cord loose, full water tank. | Check power connection, plug in securely, drain water tank. |
| Unit not cooling effectively. | Window kit not properly installed, room too large, air filter dirty, doors/windows open. | Ensure window kit is sealed, check room size, clean air filter, close all doors/windows. |
| Unusual noise. | Unit not level, foreign object in fan, normal operation noise. | Place on level surface, check for obstructions (unplug first!), some noise is normal. |
| Water leakage. | Drain plug loose, continuous drainage hose kinked/blocked. | Secure drain plug, straighten/clear drainage hose. |
| Remote control not working. | Batteries dead, obstruction between remote and unit. | Replace batteries, ensure clear line of sight to unit's receiver. |
7. Specifications
| Feature | Detail |
|---|---|
| Brand | Avalla |
| Model | AVS-50 |
| Cooling Capacity | 3000 BTU |
| Coverage Area | Up to 12m3 |
| Dehumidification Capacity | 7.2 litres/day |
| Noise Level | 45 dB (min) |
| Energy Efficiency Rating | Class A |
| Refrigerant | R-290 (Eco-friendly) |
| Power Consumption (Cooling) | 340W (approx.) |
| Dimensions (H x W x D) | 58 x 26.6 x 27 cm |
| Weight | 14.5 kg |
Video 7.1: Detailed overview of the Avalla S-50 Air Conditioner's features and design.
8. Warranty and Support
Avalla products come with a standard warranty. For specific warranty details, product support, or to purchase replacement parts, please refer to the warranty card included with your product or visit the official Avalla website.
For technical assistance or troubleshooting beyond this manual, please contact Avalla customer support.
Ask a question about this manual
Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.