Romwish RM-T83FT-G13-A1-TC-18DW-12P

Romwish 3FT T8 LED Tube Light Instruction Manual

Model: RM-T83FT-G13-A1-TC-18DW-12P

1. Introduction

This manual provides comprehensive instructions for the installation, operation, and maintenance of your Romwish 3FT T8 LED Tube Light. Please read this manual thoroughly before installation and retain it for future reference.

Romwish 3FT T8 LED Tube Light, 12-pack

Image 1: Romwish 3FT T8 LED Tube Lights (12-pack).

2. Safety Information

WARNING: Risk of electric shock. Always disconnect power before installation or servicing.

  • Before installation, it is crucial to verify your existing fluorescent ballast compatibility. Refer to the compatibility chart provided in this manual.
  • If the ballast is incompatible, you MUST bypass the ballast during setup for proper functionality. Connecting to an incompatible ballast will prevent the tube from lighting up and may pose risks. Never force installation.
  • For safety and seamless operation, consult a licensed electrician when uncertain about wiring procedures.
  • Do not modify wiring without electrical certification.
  • Ensure the tube is installed firmly in the fixture.
Critical Installation Notice and Ballast Compatibility List

Image 2: Critical Installation Notice and Ballast Compatibility List for T8 LED Tubes. This image details the importance of checking ballast compatibility and provides a list of compatible ballasts.

3. Package Contents

  • Romwish 3FT T8 LED Tube Light (12 units)
  • Instruction Manual

4. Specifications

SpecificationValue
BrandRomwish
Model NumberRM-T83FT-G13-A1-TC-18DW-12P
Light TypeLED
Bulb Shape SizeT8
Bulb BaseG13
Wattage14 Watts (30W Fluorescent Equivalent)
Brightness1600 Lumens
Color Temperature5000 Kelvin (Daylight)
Voltage100-240 Volts
Frequency50-60 Hertz
Lifespan50,000+ Hours
MaterialAluminum, Polycarbonate (PC)
Special FeatureRemove Ballast, Dual-Ended Power
Indoor/Outdoor UsageIndoor

5. Installation

The Romwish 3FT T8 LED Tube Light supports two installation methods: Type A (Plug & Play) and Type B (Ballast Bypass). Choose the method that best suits your existing fixture and comfort level. Always ensure power is disconnected before beginning installation.

Hand installing Romwish LED tube light into a fixture

Image 3: Easy installation of the Romwish LED tube light.

5.1. Type A: Plug & Play Installation (with compatible ballast)

  1. Turn OFF Power: Ensure the power supply to the fixture is completely turned off at the circuit breaker.
  2. Verify Ballast Compatibility: Refer to the ballast compatibility list (Image 2) to confirm your existing ballast is compatible with Type A LED tubes. If not compatible, proceed with Type B installation.
  3. Remove Old Fluorescent Tube: Carefully remove the existing fluorescent tube from the fixture.
  4. Insert LED Tube: Insert the Romwish LED tube into the fixture's sockets. Ensure it is securely seated.
  5. Restore Power: Turn the power back on at the circuit breaker. The LED tube should illuminate.

5.2. Type B: Ballast Bypass (Direct Wire) Installation

This method requires bypassing the existing ballast and directly wiring the fixture to the main power supply. This is recommended if your ballast is incompatible or to eliminate ballast-related issues and energy consumption.

  1. Turn OFF Power: Ensure the power supply to the fixture is completely turned off at the circuit breaker.
  2. Remove Old Fluorescent Tube: Carefully remove the existing fluorescent tube from the fixture.
  3. Access Ballast: Open the fixture cover to expose the ballast and wiring.
  4. Remove Ballast: Cut all input and output wires connected to the ballast. Remove the ballast from the fixture.
  5. Rewire Fixture: Connect the live (hot) wire from the power supply to one end of the fixture's tombstone (socket) and the neutral wire from the power supply to the other end of the fixture's tombstone. Ensure connections are secure using wire nuts or appropriate connectors. This tube is dual-end powered.
  6. Close Fixture: Securely close the fixture cover.
  7. Insert LED Tube: Insert the Romwish LED tube into the fixture's sockets. Ensure it is securely seated.
  8. Restore Power: Turn the power back on at the circuit breaker. The LED tube should illuminate.

Video 1: Installation Guide for Romwish T8 LED Tube Light (Type A+B). This video demonstrates both Plug & Play and Ballast Bypass wiring methods.

6. Operating Instructions

Once installed, operate the Romwish 3FT T8 LED Tube Light using the standard wall switch connected to your lighting fixture. The LED tube provides instant-on illumination without flickering or humming.

7. Maintenance

Romwish LED tube lights are designed for long-lasting, maintenance-free operation. To ensure optimal performance and longevity:

  • Cleaning: Periodically wipe the tube with a soft, dry cloth to remove dust. Do not use abrasive cleaners or solvents.
  • Inspection: Occasionally inspect the tube and fixture for any signs of damage or loose connections.
  • Replacement: If the LED tube fails, replace it with another compatible Romwish 3FT T8 LED Tube Light.

8. Troubleshooting

ProblemPossible CauseSolution
LED tube does not light up.No power to the fixture.Check circuit breaker and wall switch.
Loose connection.Ensure the tube is securely seated in the sockets. For Type B, check wire connections.
Incompatible or faulty ballast (Type A).Verify ballast compatibility (Image 2). If incompatible or faulty, perform Type B (Ballast Bypass) installation.
Incorrect wiring (Type B).Review Type B installation steps and ensure correct live/neutral connections. Consult a licensed electrician if needed.
LED tube flickers or hums.Faulty ballast (Type A).Perform Type B (Ballast Bypass) installation.
Loose connection.Ensure the tube is securely seated in the sockets.

9. Warranty and Support

Romwish 3FT T8 LED Tube Lights are backed by a 3-year unlimited warranty, ensuring peace of mind and commitment to customer satisfaction. For technical support, warranty claims, or any questions regarding your product, please refer to the contact information provided with your purchase or visit the official Romwish website.

Romwish LED tube lights installed in various residential and commercial settings

Image 4: Romwish LED tube lights are suitable for diverse residential and commercial applications.

Related Documents - RM-T83FT-G13-A1-TC-18DW-12P

Preview EIKO LED T8 Linear Tube Installation Instructions
Comprehensive installation instructions for EIKO LED T8 Type B Linear Tube lights, covering safety precautions, maintenance, and detailed wiring diagrams for retrofitting fluorescent luminaires.
Preview LED TUBE T8 UNIVERSAL: Installation and Operation Guide
Comprehensive guide for installing and operating the LED TUBE T8 UNIVERSAL, a replacement for T8 fluorescent lamps. Includes technical specifications, retrofit, and conversion instructions.
Preview Super Bright LEDs T8 LED Tube User Manual
User manual for Super Bright LEDs Single/Dual Side Type A/B T8 LED Tubes, detailing safety precautions, product specifications, installation instructions for Type A and Type B, modification label requirements, and a comprehensive ballast compatibility list.
Preview TRIDONIC PC T5 TOP Ip Series: High-Efficiency Electronic Ballasts for T5 and TC-L Lamps
Discover the TRIDONIC PC T5 TOP Ip series of electronic ballasts, featuring CELMA Energy Efficiency Index A2, up to 50,000 hours nominal life, and reliable performance for T5 and TC-L fluorescent lamps. Ideal for various lighting applications, these ballasts ensure stable luminous flux and support extensive lamp starts. View technical specifications, ordering data, and installation guidelines.
Preview Philips MainsFit LED T8 Tube Installation Guide
Comprehensive installation guide for Philips MainsFit LED T8 Tube, detailing direct connection to AC line voltage without a ballast. Includes safety warnings, wiring instructions, and compliance information.
Preview LED TUBE T8 EM ULTRA OUTPUT S: Installation Guide and Specifications
Comprehensive installation instructions, technical specifications, and compatibility details for the LEDVANCE LED TUBE T8 EM ULTRA OUTPUT S, a replacement for traditional T8 fluorescent lamps. Covers EM ballast and AC mains conversion.