1. Introduction

The SANICO Anti-Decubitus Mattress System is designed to provide comfort and aid in the prevention and management of pressure injuries (decubitus ulcers) for bedridden or immobilized individuals. This system utilizes an inflatable mattress with alternating air cells and a motorized compressor to continuously redistribute pressure, promoting better blood circulation and skin health.

This manual provides essential information for the safe and effective setup, operation, and maintenance of your SANICO Anti-Decubitus Mattress System. Please read it thoroughly before use and retain it for future reference.

2. Safety Instructions

Always follow these safety precautions to prevent injury or damage to the product:

  • Electrical Safety: Ensure the compressor is connected to a grounded power outlet of the correct voltage. Do not operate the compressor with wet hands or in wet conditions. Keep the power cord away from heat sources and sharp edges.
  • Weight Capacity: Do not exceed the maximum weight capacity of 160 kg (352 lbs) for the mattress. Exceeding this limit can damage the mattress and compromise its effectiveness.
  • Flammable Materials: Keep the mattress and compressor away from open flames, cigarettes, and other ignition sources.
  • Sharp Objects: Avoid placing sharp objects on or near the mattress, as they can puncture the air cells.
  • Supervision: This product is intended for use by or under the supervision of a caregiver for individuals who are bedridden or have limited mobility.
  • Cleaning: Disconnect the compressor from the power supply before cleaning. Use only mild cleaning agents as instructed in the Maintenance section.
  • Ventilation: Ensure the compressor is placed in a well-ventilated area to prevent overheating. Do not cover the compressor's air vents.

3. Package Contents

Verify that all components are present and undamaged upon opening the package:

  • 1 x SANICO Inflatable Anti-Decubitus Mattress
  • 1 x Motorized Air Compressor
  • 1 x Set of Connecting Hoses
  • 1 x User Manual (this document)
SANICO Anti-Decubitus Mattress System with compressor

Image: The complete SANICO Anti-Decubitus Mattress System, showing the inflatable mattress and the motorized air compressor unit.

4. Setup

Follow these steps to set up your SANICO Anti-Decubitus Mattress System:

  1. Prepare the Bed: Place the mattress on a standard bed frame or existing mattress. Ensure the bed surface is clean and free of sharp objects. The mattress features integrated end flaps for a secure fit.
  2. Unroll the Mattress: Carefully unroll the inflatable mattress on the bed. Ensure the air cells are facing upwards.
  3. Position the Compressor: Place the motorized air compressor on a stable, flat surface near the bed, ensuring it is within reach of a power outlet and the mattress connection points. Ensure adequate ventilation around the compressor.
  4. Connect Hoses: Connect the air hoses from the mattress to the corresponding ports on the compressor. Ensure a secure and airtight connection.
  5. Power On: Plug the compressor's power cord into a grounded electrical outlet. Turn the power switch on the compressor to the "ON" position.
  6. Initial Inflation: The compressor will begin to inflate the mattress. This process typically takes a few minutes. Allow the mattress to fully inflate before use.
Person adjusting the SANICO compressor

Image: A person adjusting the settings on the SANICO air compressor unit, which is connected to the mattress.

Hands adjusting the SANICO mattress

Image: Close-up of hands adjusting the SANICO anti-decubitus mattress, showing the individual air cells.

5. Operating Instructions

Once the mattress is fully inflated, it will begin its alternating pressure cycle.

  • Alternating Pressure: The compressor will alternately inflate and deflate different sections of the mattress every 12 minutes. This continuous pressure redistribution helps to prevent pressure points and promote blood flow.
  • Pressure Adjustment: Use the rotary knob on the compressor to adjust the air pressure within the mattress. Turn the knob clockwise to increase pressure and counter-clockwise to decrease pressure. Adjust the pressure according to the user's comfort and weight, typically within the range of 40-100 mmHg (+/-10).
  • Low Air Loss Feature: The mattress is designed with low air loss holes that provide continuous ventilation, helping to keep the skin dry and comfortable.
  • Continuous Operation: For optimal pressure injury prevention, the system should be operated continuously while the user is on the mattress.
Close-up of SANICO mattress ventilation cells

Image: A close-up view of the individual air cells on the SANICO mattress, highlighting the "VENTILATION" feature.

6. Maintenance

Proper maintenance ensures the longevity and effectiveness of your system.

  • Cleaning the Mattress:
    • Disconnect the compressor from power.
    • Wipe the mattress surface with a damp cloth using a mild detergent or disinfectant.
    • Do not immerse the mattress in water.
    • Allow the mattress to air dry completely before reconnecting the compressor or storing.
  • Cleaning the Compressor:
    • Ensure the compressor is unplugged.
    • Wipe the exterior of the compressor with a dry or slightly damp cloth.
    • Do not use abrasive cleaners or immerse the compressor in water.
    • Keep the air intake filter (if accessible) clean and free of dust to ensure proper airflow.
  • Storage: When not in use, ensure the mattress is deflated, clean, and dry. Fold or roll the mattress neatly and store it in a cool, dry place away from direct sunlight and sharp objects.
  • Regular Inspection: Periodically inspect the mattress and hoses for any signs of wear, punctures, or damage. Check the compressor's power cord for fraying or damage. If any damage is found, discontinue use and contact customer support.
Folded SANICO anti-decubitus mattress

Image: The SANICO anti-decubitus mattress neatly folded for storage or transport.

7. Troubleshooting

If you encounter issues with your SANICO Anti-Decubitus Mattress System, refer to the table below:

ProblemPossible CauseSolution
Compressor not turning on.No power supply; Power switch off; Faulty power cord.Check power outlet; Ensure switch is ON; Inspect power cord for damage.
Mattress not inflating or losing air.Hoses not securely connected; Puncture in mattress; Compressor malfunction.Ensure hoses are firmly attached; Inspect mattress for holes (use soapy water to find leaks); Contact customer support if compressor is faulty.
Mattress too soft/hard.Pressure setting incorrect.Adjust the rotary knob on the compressor to increase or decrease pressure.
Compressor making unusual noise.Blocked air intake; Internal malfunction.Check and clean air intake filter; If noise persists, contact customer support.

8. Specifications

FeatureDetail
BrandSANICO
Model NumberPL022
Mattress Dimensions (L x W x H)280 x 90 x 6.5 cm (approx.)
Maximum Weight Capacity160 kg (352 lbs)
MaterialPolyvinyl Chloride (PVC)
Compressor Air Output5 liters/minute
Air Pressure Range40-100 mmHg (+/-10)
Cycle Time12 minutes (alternating pressure)
Special FeaturesAlternately inflatable air pockets, Low air loss holes, Integrated end flaps
Intended UseHome healthcare, Temporary bed, Immobilized patient care
SANICO mattress with 160 kg weight capacity label

Image: The SANICO anti-decubitus mattress highlighting its anti-decubitus function and maximum weight capacity of 160 kg.

9. Warranty and Support

For warranty information or technical support, please contact your retailer or the manufacturer directly. Keep your purchase receipt as proof of purchase.

Manufacturer: Xiamen Sen Yang Co. L.T.D.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.