BSIDE ZT-702S Handheld Oscilloscope Digital Multimeter User Manual
Model: ZT-702S
1. Introduction
The BSIDE ZT-702S is a versatile 2-in-1 handheld device combining the functionalities of a digital oscilloscope and a true RMS multimeter. Designed for ease of use and efficiency, it features a 2.8-inch full-view IPS color LCD screen, providing clear and intuitive readings. This device is suitable for a wide range of applications, including household electrical testing, automotive diagnostics, and circuit system analysis.
Key features include a 10MHz bandwidth, 48MSa/s real-time sampling rate, and a 9999-count multimeter. It supports automatic waveform capture, multiple trigger modes, and data storage in picture form. The ZT-702S is built with safety in mind, meeting CTA III 1000V and CTA II 600V safety standards, and features safety overload protection with double ceramic fuses.
2. What's in the Box
Upon opening the package, please verify that all components listed below are present and in good condition:
- 1 x BSIDE ZT-702S Oscilloscope TRMS Multimeter
- 1 x Test Leads
- 1 x Oscilloscope Probe
- 1 x Thermocouple
- 1 x Carrying Case
- 1 x Screwdriver
- 1 x User Manual (this document)
- 1 x TYPE-C USB Cable (for charging)

Figure 2.1: All items included in the BSIDE ZT-702S package.
3. Setup
3.1 Charging the Device
The BSIDE ZT-702S comes with an integrated rechargeable battery. Before first use, or when the battery indicator shows low charge, connect the device to a DC 5V power source using the provided TYPE-C USB cable.
- Locate the TYPE-C USB port on the side of the device.
- Insert one end of the USB cable into the device's port.
- Connect the other end of the USB cable to a standard USB power adapter (not included) or a computer's USB port.
- The screen will display a charging indicator. Allow the device to charge fully before extensive use.

Figure 3.1: USB-C charging port location.
3.2 Initial Power On
To power on the device, press and hold the REL button (usually marked with a power symbol) until the screen illuminates. The device will boot up and display the main interface.

Figure 3.2: Front panel with power button highlighted.
4. Operating Instructions
4.1 Switching Between Oscilloscope and Multimeter Modes
The BSIDE ZT-702S features a dedicated MODE button for quick switching between its oscilloscope and multimeter functions. Press this button to toggle between the two primary operating modes.

Figure 4.1: Location of the MODE button.
4.2 Oscilloscope Function
In oscilloscope mode, the device displays waveforms, allowing for detailed analysis of electrical signals. It offers a 10MHz bandwidth and a 48MSa/s real-time sampling rate.
- Automatic Waveform Capture: Press the AUTO RANGE button (or similar, depending on specific button mapping) for one-key automatic waveform capture, simplifying setup.
- Trigger Modes: Select from three trigger modes: Auto, Normal, and Single. These modes control when the oscilloscope captures and displays a waveform.
- Waveform Data Storage: The device supports storing current waveform data in picture form. This allows for later review or transfer to a PC.
- Square Wave Output: A 3V-1kHz square wave output is available for testing purposes.

Figure 4.2: Oscilloscope mode in operation.
4.3 Multimeter Function
In multimeter mode, the device functions as a 9999-count true RMS multimeter, capable of measuring various electrical parameters.
- Voltage Measurement: Measures AC/DC voltage.
- Current Measurement: Measures AC/DC current.
- Resistance Measurement: Measures electrical resistance.
- Capacitance Measurement: Measures capacitance.
- Frequency Measurement: Measures signal frequency.
- Temperature Measurement: Measures temperature using the included thermocouple.
- Diode Test: Checks the functionality of diodes.
- Continuity Test: Checks for electrical continuity in circuits.

Figure 4.3: Multimeter mode displaying a voltage reading.
4.4 Display and Controls
The 2.8-inch IPS color screen provides a clear display of readings and waveforms. The device features multi-function keys for intelligent adjustment and navigation.
- F1-F4 Buttons: Function buttons, their purpose changes based on the current mode and menu.
- MENU Button: Accesses the device's settings and advanced options.
- Navigation Pad: Used for navigating menus and adjusting parameters.
- HOLD/SAVE Button: Freezes the current reading or saves data.
- AUTO POWER OFF: The device has an adjustable automatic shutdown feature to conserve battery.
- Adjustable Backlight: The screen backlight can be adjusted for optimal visibility in various lighting conditions.
5. Maintenance
5.1 Cleaning
To ensure the longevity and proper functioning of your device, keep it clean and free from dust and debris.
- Wipe the device with a soft, dry cloth.
- For stubborn dirt, use a slightly damp cloth with mild detergent, then wipe dry immediately.
- Do not use abrasive cleaners, solvents, or strong chemicals, as these can damage the casing or screen.
5.2 Battery Care
The device is powered by a rechargeable Lithium Ion battery. Proper battery care extends its lifespan.
- Avoid fully discharging the battery frequently.
- Charge the device regularly, even if not in constant use, to maintain battery health.
- Store the device in a cool, dry place when not in use for extended periods.
5.3 Fuse Replacement
The device is equipped with double ceramic fuses for protection. If the current measurement function fails, a fuse may need replacement. Refer to a qualified technician for fuse replacement to ensure safety and proper functionality.

Figure 5.1: Input jacks with fuse protection indicators.
6. Troubleshooting
This section addresses common issues you might encounter with your BSIDE ZT-702S. If the problem persists after trying these solutions, please contact customer support.
| Problem | Possible Cause | Solution |
|---|---|---|
| Device does not power on. | Low or depleted battery. | Connect the device to a charger using the TYPE-C USB cable and allow it to charge for at least 30 minutes before attempting to power on again. |
| Screen is dim or unreadable. | Backlight setting is too low; environmental lighting. | Adjust the backlight brightness through the device's menu settings. Ensure you are operating in appropriate lighting conditions. |
| Inaccurate multimeter readings. | Incorrect measurement range; faulty test leads; uncalibrated device. | Ensure the correct measurement range is selected (use AUTO RANGE if available). Check test leads for damage or loose connections. If issues persist, contact support for calibration advice. |
| No waveform displayed in oscilloscope mode. | Incorrect trigger settings; no input signal; probe not connected properly. | Verify the input signal is present. Check oscilloscope probe connection. Adjust trigger settings (mode, level) or use the AUTO function. |
| Current measurement not working. | Blown fuse. | This indicates a blown fuse. Fuse replacement should be performed by a qualified technician. |
7. Specifications
Detailed technical specifications for the BSIDE ZT-702S:
| Parameter | Value |
|---|---|
| Display | 9999 counts, 2.8 inch Full-view IPS Colour LCD Screen |
| Bandwidth | 10MHz |
| Real-time Sampling Rate | 48MSa/s |
| Input Impedance | 1MΩ, @16pf |
| Maximum Input Voltage | 400V (DC+AC peak) |
| Horizontal SEC Range | 50ns/div - 20s/div |
| Vertical Sensitivity | 20mV/div - 10V/div |
| DC Voltage | 9.999mV to 999.9V (Accuracy: ±0.5%+3) |
| AC Voltage | 9.999mV to 750.0V (Accuracy: ±1.0%+3) |
| DC Current | 9999µA to 9.999A (Accuracy: ±0.8%+3 to ±1.0%+3) |
| AC Current | 9999µA to 9.999A (Accuracy: ±1.0%+3 to ±1.2%+3) |
| Resistance | 99.99Ω to 99.99MΩ (Accuracy: ±0.5%+3 to ±3.0%+5) |
| Capacitance | 9.999nF to 9.999mF (Accuracy: ±2.0%+5 to ±5.0%+20) |
| Frequency | 99.99Hz to 5.000MHz (Accuracy: ±0.1%+2) |
| Temperature | -20℃ to 1000℃ / -4℉ to 1832℉ (Accuracy: ±2.5%+5) |
| Diode | Yes |
| Continuity | Yes |
| Power | Rechargeable battery with TYPE-C USB cable DC 5V |
| Safety Standards | CAT III 1000V (Multimeter Mode), CAT II 600V (Oscilloscope Mode) |
| Dimensions | 177mm (6.97in) x 89mm (3.51in) x 40mm (1.57in) (Approximate) |
| Weight | 1.5 Pounds (Approximate) |

Figure 7.1: Device dimensions.
8. Safety Information
Please read and understand all safety warnings and operating instructions before using this device. Failure to do so may result in injury or damage to the device.
- Always adhere to the specified maximum input voltages: 400V (DC+AC peak).
- Ensure the device is in the correct mode (oscilloscope or multimeter) and range before making measurements.
- Do not use the device if it appears damaged or if the test leads are compromised.
- The device meets CAT III 1000V safety standards in multimeter mode and CAT II 600V in oscilloscope mode. Always use appropriate safety precautions for the voltage levels being measured.
- The device features safety overload protection and double ceramic fuses. Do not bypass or modify these safety features.
- Avoid operating the device in wet or damp conditions.
- Keep the device away from strong electromagnetic fields.
9. Warranty and Support
BSIDE products are manufactured to high-quality standards. For information regarding warranty coverage, technical support, or service, please refer to the contact information provided with your purchase or visit the official BSIDE website.
Please retain your purchase receipt as proof of purchase for warranty claims.