UMF RUHLA 1062M-2

UMF RUHLA Autokinetic 1062M-2 Men's Watch User Manual

Model: 1062M-2 | Brand: UMF RUHLA

Introduction

Thank you for choosing the UMF RUHLA Autokinetic 1062M-2 men's watch. This timepiece combines traditional German craftsmanship with modern design, featuring an automatic movement and a stylish Milanese mesh strap. This manual provides essential information for the proper setup, operation, maintenance, and care of your watch to ensure its longevity and accurate performance.

Product Overview

UMF RUHLA Autokinetic 1062M-2 watch with black dial and Milanese mesh strap

Image: The UMF RUHLA Autokinetic 1062M-2 watch, showcasing its black dial, silver-tone hands and markers, and the finely woven Milanese mesh strap. The watch features a classic round case design.

The Autokinetic 1062M-2 is an automatic watch, meaning it is powered by the motion of your wrist and does not require a battery. It features a durable stainless steel case, a sophisticated black dial, and a comfortable, adjustable Milanese mesh strap. The watch is designed for daily wear and offers reliable timekeeping.

Setup

Initial Winding

As an automatic watch, the 1062M-2 requires initial winding if it has stopped. To wind the watch:

  1. Gently unscrew the crown (if it's a screw-down crown) or pull it out to position 1 (neutral position).
  2. Turn the crown clockwise approximately 30-40 times. This will build up a power reserve.
  3. Push the crown back into its original position.

Once initially wound, the watch will continue to operate as long as it is worn regularly. Daily wear for 8-10 hours should be sufficient to maintain the power reserve.

Adjusting the Milanese Mesh Strap

The Milanese mesh strap is adjustable to fit various wrist sizes. To adjust:

  1. Locate the clasp on the strap.
  2. Using a small flat-head screwdriver or a specialized watch tool, gently lift the locking plate on the clasp.
  3. Slide the clasp along the mesh strap to the desired position.
  4. Press the locking plate back down firmly until it clicks into place. Ensure it is securely fastened to prevent accidental opening.

Ensure the strap is not too tight or too loose for comfortable wear and proper automatic winding.

Operating Instructions

Setting the Time

To set the time on your Autokinetic 1062M-2 watch:

  1. Pull the crown out to position 2 (the outermost position). The second hand will stop.
  2. Turn the crown clockwise or counter-clockwise to set the hour and minute hands to the correct time.
  3. Once the time is set, push the crown back into position 1 (neutral position) to restart the second hand.

Note: This model is assumed to be time-only based on provided product details.

Power Reserve

The watch has a power reserve that allows it to run for a certain period when not worn. A fully wound watch typically has a power reserve of 36-40 hours. If the watch stops, simply re-wind it manually or wear it for a few hours to restart the movement.

Maintenance and Care

  • Cleaning: Wipe the watch case and strap regularly with a soft, dry cloth to remove dust and perspiration. For the Milanese mesh strap, a soft brush can be used to gently clean between the links.
  • Water Resistance: While the watch is designed for daily wear, avoid prolonged exposure to water, such as swimming or showering, unless explicitly stated otherwise in the specifications. Always ensure the crown is fully pushed in.
  • Temperature: Avoid exposing the watch to extreme temperatures (above 60°C / 140°F or below 0°C / 32°F) or sudden temperature changes, as this can affect the movement's accuracy and seals.
  • Magnetic Fields: Keep the watch away from strong magnetic fields (e.g., speakers, refrigerators, mobile phones, airport security scanners) as magnetism can affect the accuracy of mechanical movements.
  • Impact: Protect the watch from strong impacts or shocks, which can damage the internal mechanism.
  • Servicing: For optimal performance and longevity, it is recommended to have your automatic watch serviced by a qualified watchmaker every 3-5 years.

Troubleshooting

ProblemPossible CauseSolution
Watch stops or runs intermittentlyInsufficient power reserveManually wind the watch (30-40 turns of the crown) or wear it consistently for several hours.
Watch runs too fast or too slowExposure to magnetic fields; requires regulationDemagnetize the watch (can be done by a watchmaker). If problem persists, seek professional servicing for regulation.
Crown is difficult to pull out or push inDirt accumulation; bent stemDo not force the crown. Consult a qualified watchmaker for inspection and repair.
Condensation under the crystalMoisture ingress; seal compromiseImmediately take the watch to a watchmaker. Moisture can severely damage the movement.

Specifications

  • Model: 1062M-2
  • Movement: Automatic (Self-winding mechanical)
  • Case Material: Stainless Steel
  • Dial Color: Black
  • Strap Material: Milanese Mesh (Stainless Steel)
  • Origin: Made in Germany
  • Water Resistance: Limited splash resistance. Not suitable for swimming or showering.
  • Power Reserve: Approximately 36-40 hours (when fully wound)

Warranty Information

UMF RUHLA watches are manufactured to high-quality standards. This watch comes with a standard manufacturer's warranty covering defects in materials and workmanship under normal use. The warranty period typically begins from the date of purchase. Please retain your proof of purchase for warranty claims.

The warranty generally does not cover:

  • Damage resulting from improper handling, lack of care, accidents, or normal wear and tear.
  • Damage caused by unauthorized repairs or modifications.
  • Damage to the strap, crystal, or battery (if applicable).
  • Water damage if the watch was exposed to conditions beyond its specified water resistance.

For specific warranty terms and conditions, please refer to the warranty card included with your purchase or visit the official UMF RUHLA website.

Customer Support

Should you require assistance, have questions about your UMF RUHLA Autokinetic 1062M-2 watch, or need to arrange for service, please contact our customer support team.

Contact Information:

  • Website: www.umf-ruhla.de
  • Email: support@umf-ruhla.de
  • Phone: Please refer to the contact section on the official website for regional phone numbers.

When contacting support, please have your watch model number (1062M-2) and proof of purchase readily available.

© 2024 UMF RUHLA. All rights reserved.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.