Livguard LG1450i

Livguard LG1450i Inverter 1100VA/12V User Manual

Model: LG1450i

1. Introduction

Thank you for choosing the Livguard LG1450i Inverter. This square wave inverter is designed to provide reliable power backup for your home, office, or shop, ensuring an uninterrupted supply of electricity. With a VA rating of 1100VA/12V and a peak load capacity of 924W, it supports a variety of appliances. This manual provides essential information for the safe installation, operation, and maintenance of your inverter.

Livguard LG1450i Inverter front view

Figure 1: Livguard LG1450i Inverter. This image shows the compact design of the inverter unit.

2. Safety Instructions

Please read and understand all safety instructions before installing or operating the inverter. Failure to follow these instructions may result in electric shock, fire, or serious injury.

  • Installation: Ensure installation is performed by qualified personnel.
  • Ventilation: Install the inverter in a well-ventilated area to prevent overheating.
  • Water Exposure: Keep the inverter away from water, moisture, and flammable materials.
  • Battery Connection: Connect batteries with correct polarity (+ to + and - to -). Incorrect connection can damage the inverter and battery.
  • Grounding: Ensure the inverter is properly grounded.
  • Children and Pets: Keep the inverter out of reach of children and pets.
  • Servicing: Do not attempt to open or service the inverter yourself. Refer all servicing to authorized service personnel.

3. Product Overview

3.1. Components and Indicators

The Livguard LG1450i Inverter features a user-friendly design with clear indicators and accessible connection points.

Livguard LG1450i Inverter front and rear panel diagram

Figure 2: Front and Rear Panel Layout. This diagram illustrates the various indicators, switches, and connection terminals on the inverter.

  • Front Panel Indicators: Mains ON, Charging, UPS ON, Inverter ON/Overload/Short Circuit, Low Battery, Eco Mode, Power ON.
  • Power ON/OFF Switch: Controls the main power to the inverter.
  • Rear Panel Connections: Mains Cord, Output Socket, Thermal Circuit Breaker, Battery Terminals (+VE and -VE), Fan.
  • Selection Switches: Charging Selection, UPS/ECO Mode Selection, Battery Type Selection.

3.2. Key Features

The LG1450i Inverter incorporates advanced features for optimal performance and battery longevity.

Livguard LG1450i Inverter key features diagram

Figure 3: Smart Power Solution Features. This image highlights the core technologies and design elements of the inverter.

  • Artificial Intelligent Charging: Analyzes battery health and applies suitable charging current, preventing overcharging and enhancing battery life.
  • UPS and ECO Mode Support: Dual mode operation for sensitive appliances (UPS mode) and extended backup (ECO mode).
  • Four Type Battery Selector Switch: Compatible with Flat Plate, Tubular, SMF, and LOCAL battery types for optimized charging.
  • Dual Thermal Protect: Provides surge protection for the PCB and transformer.
  • Premium New Age Design: Modern aesthetic with an LED display.

4. Setup and Installation

Proper installation is crucial for the safe and efficient operation of your inverter. It is recommended that installation be performed by a certified technician.

  1. Unpacking: Carefully unpack the inverter and inspect for any damage. Report any damage to your dealer immediately.
  2. Placement: Place the inverter in a cool, dry, well-ventilated area, away from direct sunlight, heat sources, and flammable materials. Ensure adequate clearance around the unit for airflow.
  3. Battery Connection:
    • Ensure the inverter is OFF before connecting batteries.
    • Connect the positive (+) terminal of the battery to the positive (+VE) terminal on the inverter.
    • Connect the negative (-) terminal of the battery to the negative (-VE) terminal on the inverter.
    • Tighten all battery terminal connections securely.
  4. Mains Power Connection: Plug the inverter's mains cord into a properly grounded wall outlet.
  5. Appliance Connection: Plug your appliances into the output socket(s) on the rear panel of the inverter. Do not exceed the inverter's rated load capacity.
  6. Battery Type Selection: Use the 4-mode selector switch on the rear panel to select the correct battery type (Flat Plate, Tubular, SMF, or LOCAL) for your connected battery. This optimizes charging.
  7. Initial Power On: After all connections are secure, switch the inverter ON using the power button on the front panel.

5. Operating Instructions

5.1. Powering On/Off

  • To Power On: Press the Power ON/OFF switch on the front panel. The "Power ON" indicator will illuminate.
  • To Power Off: Press the Power ON/OFF switch again. All indicators will turn off.

5.2. Mode Selection (UPS/ECO)

The inverter offers two operating modes:

  • UPS Mode: Provides a continuous, stable power supply, ideal for sensitive electronic appliances like computers, laptops, and LED TVs. In this mode, the transfer time from mains to battery power is minimal. The "UPS ON" indicator will be lit.
  • ECO Mode: Designed for extended backup time and less sensitive appliances. In this mode, the transfer time is slightly longer, but it optimizes battery usage. The "Eco Mode" indicator will be lit.

Use the UPS/ECO Mode Selection switch on the rear panel to toggle between these modes.

5.3. Indicator Lights

The front panel LEDs provide status information:

  • Mains ON: Indicates that the inverter is receiving power from the utility grid.
  • Charging: Indicates that the battery is currently being charged.
  • UPS ON: Indicates the inverter is operating in UPS mode.
  • Inverter ON/Overload/Short Circuit: Indicates the inverter is supplying power. If flashing or accompanied by an alarm, it may indicate an overload or short circuit.
  • Low Battery: Indicates the battery charge is low and requires recharging. The inverter will switch off automatically if the battery level drops too low.
  • Eco Mode: Indicates the inverter is operating in ECO mode.
  • Power ON: Indicates the inverter is powered on.

6. Maintenance

The Livguard LG1450i Inverter is designed for low maintenance. However, following these guidelines will ensure optimal performance and extend its lifespan.

  • Cleaning: Keep the inverter clean and free from dust. Use a dry cloth to wipe the exterior. Do not use liquid cleaners.
  • Ventilation: Ensure the ventilation openings are not blocked to prevent overheating.
  • Battery Care:
    • Regularly check battery water levels if using a flooded lead-acid battery (as per battery manufacturer's instructions).
    • The Smart AI Charging feature helps maintain battery health by preventing overcharging.
    • Ensure battery terminals are clean and free from corrosion.
  • Connections: Periodically check all electrical connections for tightness and signs of wear.
  • Storage: If storing the inverter for an extended period, ensure the battery is fully charged and disconnect it from the inverter. Recharge the battery every 3-6 months to prevent deep discharge.

7. Troubleshooting

This section addresses common issues you might encounter with your Livguard LG1450i Inverter.

ProblemPossible CauseSolution
Inverter not turning ON
  • Power switch is OFF
  • Battery not connected or low charge
  • Mains power not available
  • Press the Power ON/OFF switch
  • Check battery connections and charge level
  • Verify mains power supply
No output from inverter (Inverter ON indicator flashing/alarm)
  • Overload
  • Short circuit in connected appliance
  • Low battery voltage
  • Reduce connected load
  • Check appliances for short circuits
  • Allow battery to charge
Battery not charging (Charging indicator OFF)
  • Mains power not available
  • Loose battery connections
  • Incorrect battery type selection
  • Check mains power supply
  • Secure battery connections
  • Verify battery type selection switch setting
Inverter switches OFF suddenly
  • Low battery voltage
  • Overload
  • Overheating
  • Allow battery to charge
  • Reduce connected load
  • Ensure proper ventilation, check fan operation

If the problem persists after attempting these solutions, please contact Livguard customer support.

8. Specifications

FeatureDetail
BrandLivguard
Model NameLG1450i
Inverter TypeSquare Wave Inverter
VA Rating1100 VA
Input Voltage12 Volts
Output Voltage220 Volts
Peak Load / Wattage924 Watts
Output Power1030 Watts
Frequency50 Hz
Battery Compatibility1 x (12V) C20 battery, 90 Ah - 260 Ah
Dimensions (L x W x H)27.5L x 28.1W x 14.5H Centimeters
Weight10.9 kg (10900 Grams)
ColorBlack
Box Contents1 Inverter, Instruction Manual

8.1. Appliance Load Capacity

The following table provides an estimated load capacity for various appliances with the LG1450i (1100 VA, 12V) model.

Appliance load capacity table for Livguard inverters

Figure 4: Appliance Load Capacity. This table helps in understanding the number of common appliances that can be supported by different Livguard inverter models, including the LG1450i.

Note: Backup time depends on battery Ah and condition. Load of appliances depends on Inverter VA. Please check the power consumption of your appliances to choose the suitable Inverter.

9. Warranty

The Livguard LG1450i Inverter comes with a 3-year manufacturer warranty from the date of purchase. Please retain your purchase receipt for warranty claims.

Livguard 3-year warranty information

Figure 5: Warranty Coverage. This image confirms the 3-year warranty period for the inverter.

The warranty covers manufacturing defects. It does not cover damage due to improper installation, misuse, unauthorized repairs, or natural disasters. For detailed warranty terms and conditions, refer to the warranty card included with your product.

10. Customer Support

For any queries, technical assistance, or warranty claims, please contact Livguard customer support:

  • WhatsApp Support: +91 - 74281 91000 (automated service)
  • Phone Support: 1800 102 5551
  • Manufacturer Address: Livguard Batteries Pvt. LTD., Plot No. - 221, Udyog Vihar Phase - 1, Gurugram - 122016, Haryana India

Livguard also offers 100% free doorstep installation service across a network of 16,000+ pin codes in India, supported by a team of 750+ certified service engineers.

Livguard Pan India service network map

Figure 6: Pan India Service Network. This image illustrates the extensive service coverage provided by Livguard across India.

© 2024 Livguard. All rights reserved.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.