1. Introduction
This manual provides comprehensive instructions for the installation, operation, and maintenance of the IMIT TC2 1750 542470 Temperature Controller. Please read this manual thoroughly before using the device to ensure safe and efficient operation.
2. Safety Information
Important Safety Instructions:
- Installation and maintenance must be performed by qualified personnel only, in accordance with local electrical codes and regulations.
- Disconnect power to the device before performing any installation, wiring, or maintenance procedures.
- Ensure the power supply voltage matches the specifications of the controller.
- Do not expose the controller to excessive moisture, dust, or corrosive environments.
- Verify all connections are secure and properly insulated to prevent electrical hazards.
- This device is designed for temperature control applications within its specified range. Do not use it for purposes other than its intended use.
3. Product Overview
The IMIT TC2 1750 542470 is an adjustable temperature controller designed for various applications requiring precise temperature regulation. It functions as a thermostat, allowing users to set a desired temperature within its operational range.

Figure 1: IMIT TC2 1750 542470 Temperature Controller. The image displays the orange controller unit with its brass probe, alongside its yellow packaging box and a partial view of the instruction manual showing a wiring diagram (fig.5 - εικ.5). The controller's label indicates "TYPE TC2 1750 542470", "IP 40", and electrical ratings for contacts C-1 and C-2.
Key Features:
- Adjustable temperature range: 0-90 degrees Celsius.
- Model number: TC2 1750 542470.
- Ingress Protection (IP) rating: IP40.
- Equipped with electrical contacts C-1 and C-2 for control circuitry.
4. Setup and Installation
Proper installation is critical for the safe and accurate operation of the temperature controller. It is recommended that installation be performed by a qualified electrician or technician.
- Mounting: Securely mount the controller in a suitable location, ensuring it is protected from direct exposure to water or excessive dust, consistent with its IP40 rating.
- Probe Placement: Insert the temperature sensing probe into the medium or area where temperature control is required. Ensure good thermal contact for accurate readings.
- Wiring:
- Refer to the wiring diagram provided with the product (e.g., "fig.5 - εικ.5" as seen in Figure 1) for specific connection details.
- Connect the power supply to the designated terminals.
- Connect the load (e.g., heating element, cooling unit) to the appropriate control contacts (C-1, C-2).
- Ensure all wiring adheres to the specified electrical ratings:
- Contact C-1: 10(2.5)A, 250V~
- Contact C-2: 1(0.2)A, 250V~
- Double-check all connections for tightness and correct polarity.
- Power On: Once all connections are verified, restore power to the circuit.
5. Operating Instructions
The IMIT TC2 1750 542470 is an adjustable thermostat. To set the desired temperature:
- Locate the adjustment dial or screw on the controller.
- Carefully turn the dial to the desired temperature setting within the 0-90°C range.
- The controller will activate or deactivate the connected load to maintain the set temperature.
- Monitor the system to ensure the controller is operating as expected and maintaining the desired temperature.
6. Maintenance
Regular maintenance helps ensure the longevity and reliable operation of your temperature controller.
- Cleaning: Periodically clean the exterior of the controller with a soft, dry cloth. Do not use abrasive cleaners or solvents. Ensure no liquids enter the device.
- Inspection: Regularly inspect the wiring connections for any signs of wear, corrosion, or loosening. Tighten connections as necessary.
- Probe Condition: Check the temperature probe for any damage or buildup that might affect its accuracy. Clean if necessary.
- Calibration Check: If precise temperature control is critical, periodically verify the controller's accuracy against a known calibrated thermometer.
7. Troubleshooting
If you encounter issues with your IMIT TC2 1750 542470, refer to the following common problems and solutions:
- Controller Not Powering On:
- Check the main power supply to the circuit.
- Verify all wiring connections are secure and correct.
- Ensure the voltage supply matches the controller's requirements.
- Incorrect Temperature Reading/Control:
- Ensure the temperature probe is correctly installed and has good thermal contact with the medium being measured.
- Check for any physical damage to the probe or its wiring.
- Verify the set temperature on the adjustment dial.
- Load Not Activating/Deactivating:
- Confirm the load (e.g., heater, cooler) is functioning correctly independently of the controller.
- Check the wiring between the controller's contacts (C-1, C-2) and the load.
- Ensure the set temperature is within the operational range and the differential is allowing for switching.
If problems persist after attempting these solutions, contact a qualified technician or the product supplier for assistance.
8. Specifications
| Model: | TC2 1750 542470 |
| Brand: | IMIT |
| Temperature Range: | 0-90°C (Degrees Celsius) |
| Ingress Protection (IP) Rating: | IP40 |
| Electrical Contacts: |
|
| Manufacturer: | IMIT (as per product labeling) |
9. Warranty and Support
For warranty information and technical support, please refer to the documentation provided at the point of purchase or contact the seller directly. Keep your purchase receipt as proof of purchase.