1. Product Overview
The LiebeWH DZ47-125 2P Miniature Circuit Breaker is an essential electrical device designed for low-voltage distribution and power systems. It integrates control and protection functions, ensuring the safety and stability of your electrical circuits.
Key features include:
- Comprehensive Protection: Provides leakage, overload, and short circuit protection.
- High Quality Components: Constructed from high-quality electronic components for stable and reliable performance.
- Fast Response: Features a rapid response speed with a leakage action time of only 0.1 second.
- Flame Retardant Casing: The outer casing is made from flame retardant material for enhanced safety.
Figure 1: Overall view of the LiebeWH DZ47-125 2P Miniature Circuit Breaker.
2. Safety Information
Please read and understand all safety instructions before installing or operating this device. Failure to follow these instructions may result in electric shock, fire, or serious injury.
- Professional Installation: Installation should only be performed by a qualified electrician in accordance with local electrical codes and regulations.
- Power Disconnection: Always ensure the main power supply is disconnected before performing any installation, wiring, or maintenance.
- Voltage and Current Ratings: Do not exceed the rated voltage (400V) or current (80A, 100A, or 125A depending on model) of the circuit breaker.
- Environmental Conditions: Do not install in environments with excessive moisture, dust, or corrosive gases.
- Flame Retardant: While the casing is flame retardant, proper wiring and installation are crucial to prevent overheating and fire hazards.
3. Components
The DZ47-125 2P Miniature Circuit Breaker consists of the following main components:
- Toggle Switch: Used to manually turn the circuit breaker ON or OFF, and indicates the tripped state.
- Terminals: Screw terminals for connecting input and output wires.
- Model and Rating Labels: Clearly marked with model number (DZ47-125), current rating (e.g., C125A), voltage, and breaking capacity.
- DIN Rail Clip: For easy mounting onto a standard DIN rail (located on the back).
Figure 2: Front view showing the toggle switch and product labels.
Figure 3: Angled view highlighting the wiring terminals.
4. Setup and Installation
Installation must be performed by a qualified professional. Ensure all power is disconnected before proceeding.
- Mounting: Securely mount the circuit breaker onto a standard DIN rail within an appropriate electrical enclosure.
- Wiring: Connect the incoming power supply to the upper terminals and the outgoing load wires to the lower terminals. This model supports front wiring. Ensure all connections are tight and secure to prevent loose contacts and overheating.
- Polarity: Observe correct polarity for DC applications if applicable, though this model is primarily for AC 400V.
- Verification: After wiring, double-check all connections for correctness and tightness.
Figure 4: Back view with DIN rail clip and removal instructions.
5. Operating Instructions
The circuit breaker is designed for simple operation:
- To Turn ON: Push the toggle switch upwards to the 'ON' position.
- To Turn OFF: Push the toggle switch downwards to the 'OFF' position.
- Tripped State: If an overload, short circuit, or leakage occurs, the toggle switch will automatically move to an intermediate or 'OFF' position, indicating a trip.
- Resetting After a Trip: Before resetting, identify and rectify the cause of the trip. Once the fault is cleared, push the toggle switch fully down to the 'OFF' position, then push it upwards to the 'ON' position to restore power.
6. Maintenance
The DZ47-125 2P Miniature Circuit Breaker requires minimal maintenance. Regular inspections are recommended to ensure optimal performance and safety.
- Visual Inspection: Periodically check the circuit breaker for any signs of physical damage, discoloration, or loose connections.
- Cleaning: Ensure the area around the circuit breaker is clean and free from dust and debris. Use a dry, soft cloth for cleaning; do not use liquids.
- No User Serviceable Parts: Do not attempt to open or repair the circuit breaker. If it is damaged or malfunctioning, it should be replaced by a qualified professional.
7. Troubleshooting
If you encounter issues with your circuit breaker, consider the following:
- Breaker Trips Frequently: This indicates an underlying electrical issue such as an overload, short circuit, or ground fault (leakage). Do not repeatedly reset the breaker without investigating the cause.
- No Power After Reset: If the breaker trips immediately after being reset, a severe fault likely persists. Disconnect all loads and try resetting again. If it still trips, consult a qualified electrician.
- Breaker Does Not Trip: If a fault is suspected but the breaker does not trip, it may be faulty. Immediately disconnect power and have it inspected by a professional.
For any persistent or complex electrical issues, always consult a certified electrician.
8. Specifications
| Specification | Value |
|---|---|
| Model | DZ47-125 2P |
| Breaking Capacity | 7.5KA |
| Number of Poles | 2P |
| Trip Unit Rated Current (Optional) | 80A; 100A; 125A |
| Rated Voltage | 400V |
| Leakage Current | 30mA |
| Leakage Action Time | ≤ 0.1S |
| Material | Copper-based alloy |
| Tripping Method | Overcurrent release type |
| Protection Types | Leakage, Overload, Short Circuit |
| Application Scenario | Terminal power distribution |
| Wiring Method | Front wiring |
| Structure Type | Plastic case circuit breaker |
| Arc Extinguishing Medium | Air type |
| Parcel Dimensions | 8 x 7 x 6 cm; 308 g |
| Country of Origin | China |
Note: Product appearance may vary slightly between new and old production batches, but functionality remains consistent. (Refer to image below for visual comparison).
Figure 5: Comparison of new and old models (shipped randomly).
9. Warranty and Support
For warranty information, technical support, or further inquiries, please contact your retailer or visit the official LiebeWH store.