Faber HOOD PRIMUS PLUS ENERGY IN HCSC BK 75

Faber 75 cm Autoclean Curved Shape Kitchen Chimney Instruction Manual

Model: HOOD PRIMUS PLUS ENERGY IN HCSC BK 75

1. Introduction

This manual provides essential information for the safe and efficient operation, installation, and maintenance of your new Faber 75 cm Autoclean Curved Shape Kitchen Chimney. Please read these instructions thoroughly before using the appliance and retain them for future reference. This chimney is designed to effectively remove smoke, grease, and odors from your kitchen environment.

Faber 75 cm Autoclean Curved Shape Kitchen Chimney front view

Figure 1: Front view of the Faber 75 cm Autoclean Curved Shape Kitchen Chimney.

2. Safety Instructions

To ensure safe operation, always adhere to the following safety guidelines:

3. Package Contents

Verify that all items are present in the package:

4. Product Features

The Faber HOOD PRIMUS PLUS ENERGY IN HCSC BK 75 chimney incorporates advanced features for enhanced kitchen ventilation:

Diagram illustrating i-clean technology, gesture control, and 1500 m3/hr suction capacity

Figure 2: Key features including i-clean technology, gesture control, and high suction power.

Diagram showing low noise levels compared to living room conversation and music

Figure 3: Illustration of the chimney's soft noise operation for a quieter cooking experience.

Close-up of the LED soft light on the chimney

Figure 4: Detail of the integrated LED soft light for illuminating the cooking area.

5. Setup and Installation

The Faber HOOD PRIMUS PLUS ENERGY IN HCSC BK 75 is a wall-mounted chimney designed for ducted ventilation. Professional installation is highly recommended to ensure proper functioning and safety.

5.1 Pre-Installation Checks

5.2 Installation Procedure (Summary)

  1. Mark the drilling points on the wall according to the provided template.
  2. Drill holes and insert wall plugs.
  3. Mount the chimney body onto the wall using the provided brackets and screws.
  4. Connect the duct pipe to the chimney outlet and route it to the exterior vent.
  5. Install the baffle filters and oil collector.
  6. Connect the chimney to the power supply.

For detailed installation instructions, please refer to the separate installation guide provided with your product or contact Faber customer support.

6. Operating Instructions

Your Faber chimney offers multiple control options for ease of use.

6.1 Control Panel Overview

Close-up of the chimney's touch control panel with power, speed, and autoclean buttons

Figure 5: Detailed view of the touch control panel.

6.2 Touch Control

6.3 Gesture Control and Motion Sensor

The chimney can be operated without physical contact using hand gestures:

Hand demonstrating gesture control on the chimney's control panel

Figure 6: Operating the chimney using gesture control.

7. Maintenance

Regular maintenance ensures optimal performance and longevity of your chimney.

7.1 Autoclean Function

The Autoclean feature uses heat to melt and collect grease, reducing manual cleaning effort. The chimney is equipped with an Autoclean alarm that notifies you when a cleaning cycle is recommended.

Chimney control panel with 'Auto Clean with I-clean technology' text and water drop icon

Figure 7: Activating the Autoclean function with I-clean technology.

7.2 Baffle Filter Cleaning

Even with Autoclean, periodic manual cleaning of baffle filters is recommended.

  1. Ensure the chimney is switched off and disconnected from power.
  2. Carefully unlatch and remove the baffle filters.
  3. Wash the filters with warm water and a degreasing detergent. For stubborn grease, soak them for a while.
  4. Rinse thoroughly and allow them to dry completely before re-installing.
Close-up of the stainless steel baffle filters inside the chimney

Figure 8: The stainless steel baffle filters, designed for efficient grease separation.

7.3 Exterior Cleaning

Wipe the exterior surfaces with a soft cloth and mild cleaning solution. Avoid abrasive cleaners or harsh chemicals.

8. Troubleshooting

Refer to this section for solutions to common issues. If the problem persists, contact customer support.

ProblemPossible CauseSolution
Chimney does not startNo power supply; Power cord loose; Fuse blownCheck power connection; Ensure cord is secure; Check household fuse/breaker.
Low suction powerClogged filters; Obstruction in ducting; Incorrect speed settingClean baffle filters; Check duct for blockages; Select higher speed.
Excessive noiseLoose parts; Improper installation; Obstruction in fanCheck for loose screws; Ensure correct installation; Inspect fan for foreign objects.
Lights not workingLED bulb failure; Electrical connection issueContact service for LED replacement; Check power.
Autoclean not functioningSystem error; Insufficient powerRestart chimney; Contact service if error persists.

9. Specifications

Detailed technical specifications for the Faber HOOD PRIMUS PLUS ENERGY IN HCSC BK 75 chimney:

FeatureSpecification
ModelHOOD PRIMUS PLUS ENERGY IN HCSC BK 75
TypeCurved Glass, Wall Mounted Chimney
Size75 cm
Suction Power1500 m³/hr
Filter TypeBaffle Filter (Stainless Steel)
Control TypeTouch Control, Gesture Control, Motion Sensor
Number of Speeds3
Noise Level58 dB
Ventilation TypeDucted/Vented
Light SourceLED (with Moodlight Feature)
MaterialGlass
Voltage220 Volts
Item Weight12 kg
Dimensions (LxWxH)75 x 42.5 x 47 Centimeters
Side view of the chimney with dimensions labeled as 48.5 CM height, 41.5 CM depth, and 75 CM width

Figure 9: Product dimensions for installation planning.

10. Warranty and Support

Faber provides comprehensive warranty coverage for your peace of mind.

For installation services, warranty claims, or technical support, please contact Faber customer care:

Customer Service Number: 1800-209-3484

Faber chimney installed in a modern kitchen with a '2 Year comprehensive & 12 years on motor' warranty badge

Figure 10: Warranty information for the Faber chimney.