1. Introduction
This instruction manual provides essential information for the safe and efficient use of the Jiayin JYPC-8 Solenoid Pump. Please read this manual thoroughly before installation, operation, or maintenance to ensure proper function and to prevent damage or injury. This pump is designed for various applications, including steam mops, electric irons, and steam cleaners.
2. Product Overview
The Jiayin JYPC-8 is a compact and reliable electromagnetic solenoid pump. It operates on AC 220V-240V at 50Hz with a power consumption of 15W, delivering a flow rate of 110 ± 10% cc/min and a maximum pressure of 3.0 bar. It features a canula connection method and is suitable for pumping water or non-corrosive liquids.




3. Specifications
| Feature | Specification |
|---|---|
| Model Number | JYPC-8 |
| Rated Voltage | AC 220V-240V |
| Frequency | 50Hz |
| Power | 15W |
| Flow Rate | 110 ± 10% cc/min |
| Max. Pressure | 3.0 bar |
| Connection Method | Canula |
| Insulation Class | H |
| Ambient Temperature | Ta 80 ℃ |
| Fluid Temperature | Tf 35 ℃ |
| Working Medium | Water or non-corrosive liquid |
| Product Dimensions (L x W x H) | 8 x 2.4 x 5.5 cm |
| Weight | 80 grams |
| Manufacturer | JIAYIN TECHNOLOGY |
| Included Components | Coil, pump body, plastic fittings |
4. Safety Information
- Always disconnect power before installing, servicing, or cleaning the pump.
- Ensure the voltage and frequency of your power supply match the pump's specifications (AC 220V-240V, 50Hz).
- Do not operate the pump with corrosive or flammable liquids. Use only with water or specified non-corrosive liquids.
- Avoid dry running the pump, as this can cause damage. Ensure there is always fluid in the system when operating.
- Keep the pump away from children and pets.
- Do not modify the pump or its components. Use only original replacement parts if necessary.
- Ensure all connections are secure and leak-free before operating.
5. Setup and Installation
- Unpack the Pump: Carefully remove the pump from its packaging and inspect it for any signs of damage.
- Mounting: Securely mount the pump in the desired location. Ensure it is stable and protected from excessive vibration.
- Fluid Connections: Connect the inlet and outlet canula fittings to your system's tubing. Ensure a tight and leak-proof connection. The pump is designed with an elbow outlet for specific routing needs.
- Electrical Connection: Connect the pump's electrical terminals to a suitable AC 220V-240V, 50Hz power supply. It is recommended to have this done by a qualified electrician to ensure proper wiring and safety.
- Priming (if necessary): Depending on your system, you may need to prime the pump by ensuring the fluid path is filled before initial operation to prevent dry running.
6. Operating Instructions
- Pre-Operation Check: Before turning on the power, verify all fluid and electrical connections are secure. Ensure the fluid reservoir is adequately filled.
- Power On: Apply power to the pump. The solenoid will activate, and the pump will begin to draw and discharge fluid.
- Monitor Operation: Observe the pump during its initial operation for any unusual noises, leaks, or performance issues.
- Power Off: To stop the pump, disconnect the power supply.
7. Maintenance
- Regular Inspection: Periodically inspect the pump for any signs of wear, damage, or leaks. Check electrical connections for corrosion or looseness.
- Cleaning: If the pump is used with water containing impurities, periodic cleaning of the inlet filter (if applicable) and internal components may be necessary to maintain optimal flow and pressure. Always disconnect power before cleaning.
- Fluid Quality: Ensure the working fluid remains clean and free of debris that could clog the pump or system.
- Storage: If storing the pump for an extended period, ensure it is drained of fluid and stored in a dry, clean environment.
8. Troubleshooting
| Problem | Possible Cause | Solution |
|---|---|---|
| Pump does not start | No power supply; Incorrect voltage; Faulty wiring; Internal pump failure | Check power connection and supply; Verify voltage matches specifications; Inspect wiring; Contact support if internal failure is suspected. |
| Low or no fluid flow | Clogged inlet/outlet; Air in the system (not primed); Low fluid level in reservoir; Kinked tubing; Internal pump issue | Check and clear any blockages; Prime the pump; Refill fluid reservoir; Straighten tubing; Contact support. |
| Unusual noise during operation | Air in the system; Loose mounting; Debris inside pump; Worn components | Bleed air from the system; Tighten mounting screws; Disconnect power and inspect for debris (if safe); Contact support for worn components. |
| Fluid leakage | Loose connections; Damaged tubing/fittings; Cracked pump housing | Tighten all connections; Replace damaged tubing or fittings; If housing is cracked, replace the pump. |
9. Warranty and Support
For warranty information or technical support, please refer to the documentation provided at the time of purchase or contact your retailer. Keep your purchase receipt as proof of purchase. For direct inquiries, you may contact JIAYIN TECHNOLOGY through their official support channels.