Hessaire DX4800S

Hessaire 4800 CFM Evaporative Cooler User Manual

Model: DX4800S

Introduction

This manual provides essential information for the safe and efficient operation, maintenance, and troubleshooting of your Hessaire 4800 CFM Evaporative Axial Fan Cooler. Please read this manual thoroughly before installation or operation.

The Hessaire 4800 CFM Universal Down-Draft Evaporative Cooler is designed for efficient cooling, coming assembled and easily installed as a Down-Draft unit. It is engineered to replace both rigid media and aspen coolers, specifically for down-draft configurations.

Important Safety Instructions

Always follow basic safety precautions when using electrical appliances to reduce the risk of fire, electric shock, and injury to persons.

Setup and Installation

The Hessaire 4800 CFM Evaporative Cooler is designed for straightforward installation. This unit comes assembled and can be easily configured for side discharge or down-draft installation.

Unpacking

Carefully remove the unit from its packaging. Inspect for any shipping damage. Retain packaging for future storage or transport.

Placement

Position the cooler on a stable, level surface. Ensure adequate clearance around the unit for optimal airflow and maintenance access. For down-draft installation, ensure the duct opening is correctly sized and sealed.

Top-down view of the Hessaire 4800 CFM Evaporative Cooler showing the large fan blades and internal structure.

Image: Top-down view of the Hessaire 4800 CFM Evaporative Cooler, illustrating the large fan blades and the internal components. This view is typical for understanding the air intake and fan mechanism for installation.

Electrical Connection

This unit operates on 115V. Ensure the electrical supply matches the unit's requirements. The cooler has an aluminum extruded PSC motor for maximum efficiency.

Connect the power cord to a grounded 115V outlet. Do not use extension cords unless absolutely necessary and ensure they are rated for the unit's wattage.

Water Connection

Connect a water supply line to the cooler's water inlet. Ensure all connections are secure and leak-free. The unit requires a continuous water supply for evaporative cooling.

Operating Instructions

The Hessaire 4800 CFM Evaporative Cooler features a 2-speed motor and an ultra-quiet prop design for efficient and quiet operation.

Controls

Locate the control panel, typically on the side or front of the unit. It usually includes controls for fan speed and pump operation.

Starting the Unit

  1. Ensure the unit is properly connected to power and water.
  2. Turn on the water pump. Allow a few minutes for the cooling media to become fully saturated.
  3. Select the desired fan speed.

Optimal Performance

For best cooling efficiency, ensure adequate ventilation in the area. Evaporative coolers work best in dry climates and require an exhaust path for humid air.

The unit utilizes hi-density rigid media for 85% cooling efficiency.

Maintenance

Regular maintenance ensures the longevity and efficient operation of your evaporative cooler.

Daily/Weekly Maintenance

Monthly/Seasonal Maintenance

Winterization

Before storing the unit for the off-season, drain all water, clean the reservoir and cooling media thoroughly, and ensure the unit is dry to prevent mold and mildew growth. Store in a dry, protected area.

Troubleshooting

This section provides solutions to common issues you might encounter.

ProblemPossible CauseSolution
Unit does not turn on.No power, tripped breaker, faulty switch.Check power cord connection, reset breaker, contact service if switch is faulty.
No cooling effect.Water pump off, low water level, clogged media.Turn on pump, check water supply, clean cooling media.
Water leakage.Loose water connection, cracked reservoir.Tighten connections, inspect reservoir for damage.
Unusual noise.Obstruction in fan, motor issue, pump issue.Inspect fan for debris, contact service for motor/pump issues. The unit has an ultra-quiet prop design, so any unusual noise should be investigated.

Product Specifications

Warranty Information

The Hessaire 4800 CFM Evaporative Cooler comes with the following warranty:

Please retain your proof of purchase for warranty claims. For detailed warranty terms and conditions, refer to the documentation included with your product or contact Hessaire customer support.

Customer Support

For technical assistance, parts, or warranty inquiries, please contact Hessaire customer support. Visit the official Hessaire website for the most up-to-date contact information.

You can also visit the Hessaire Store on Amazon for additional product information and support resources.

Related Documents - DX4800S

Preview Hessaire W6100 Window Evaporative Cooler User and Care Guide
Comprehensive guide for the Hessaire W6100 window evaporative cooler, covering safety precautions, installation, operation, maintenance, troubleshooting, specifications, and warranty information.
Preview Hessaire Evaporative Cooler Use & Care Guide
This guide provides essential information on the warranty, safety precautions, operation tips, troubleshooting, features, and maintenance for Hessaire Mobile Evaporative Coolers, including models MC37, MC61, M150, and M250.
Preview Hessaire Mobile Evaporative Cooler MC92V, M350 Use & Care Guide
Comprehensive use and care guide for the Hessaire MC92V and M350 Mobile Evaporative Coolers, including safety precautions, operation tips, maintenance, troubleshooting, parts list, and warranty information.
Preview Hessaire W6100 Window Evaporative Cooler 6700 CFM Use & Care Guide
Comprehensive use and care guide for the Hessaire W6100 Window Evaporative Cooler, featuring 6700 CFM. Includes safety precautions, installation instructions, operation tips, maintenance, troubleshooting, parts list, and warranty information.
Preview Hessaire MC26A Mobile Evaporative Cooler Use & Care Guide
Comprehensive guide for the Hessaire MC26A Mobile Evaporative Cooler, covering safety, operation, maintenance, troubleshooting, parts, and warranty information.
Preview Hessaire HTH01 Evaporative Cooler Thermostat - Features and Specifications
Detailed information on the Hessaire HTH01 line-voltage thermostat for evaporative coolers, including features, control functions, and electrical ratings for 115V and 230V operation.