1. Introduction
The DONGKER MDS-60 is a high-performance DIY metal detector kit designed for security applications and educational electronic soldering practice. This kit provides an accessible way to assemble a functional metal detector module. It is characterized by its high reliability, good stability, and compact size, making it suitable for various projects and learning experiences.

Image 1.1: Assembled DONGKER MDS-60 DIY Metal Detector Kit, showing the green PCB with a circular coil and various electronic components.
2. Specifications
The DONGKER MDS-60 Metal Detector Kit features the following technical specifications:
| Parameter | Value |
|---|---|
| Operating Voltage | DC 3-5V |
| Operating Current | Less than or equal to 40mA |
| Standby Current | 5mA |
| Detection Distance | Up to 60mm |
| Alarm Mode | Sound / Light (LED) |
| Assembly Difficulty | Easy |
| PCB Size | 86mm x 61mm |
| Item Weight (Kit) | Approximately 3.52 ounces (100g) |

Image 2.1: Detailed table showing the parameters and component list for the MDS-60 kit, essential for assembly and understanding the module's capabilities.
3. Package Contents
The DONGKER MDS-60 DIY Metal Detector Kit includes all necessary electronic components for assembly. Please verify that all parts listed below are present before beginning assembly.
| No. | Name | Parameter | Quantity |
|---|---|---|---|
| R3 | Resistor | 470R | 1 |
| R2 | Resistor | 2K | 1 |
| R1 | Resistor | 200K | 1 |
| VR1 | Adjustable Resistor | 100R | 1 |
| C2, C3 | Ceramic Capacitor | 222P | 2 |
| C1, C4 | Ceramic Capacitor | 104P | 2 |
| C5 | Electrolytic Capacitor | 100UF | 1 |
| LED1 | LED | 5mm Red | 1 |
| Q2, Q3 | Transistor (Triode) | S9012 | 2 |
| Q1 | Transistor (Triode) | S9018 | 1 |
| SW1 | Power Switch | 6P 6*5 | 1 |
| SP1 | Buzzer | 9*12 | 1 |
| J1 | Power Socket | KF301-2 | 1 |
| — | PCB | MDS-60 | 1 |
| Optional | Battery Box | AA1.5V*3 | 1 |

Image 3.1: All individual components of the MDS-60 DIY Metal Detector Kit laid out, including the PCB, resistors, capacitors, transistors, LED, buzzer, switch, and power socket.
4. Assembly Instructions
This kit requires soldering. Basic soldering skills are recommended. Please follow the component list and PCB markings carefully.
4.1 Required Tools (Not Included)
- Electric Soldering Iron
- Soldering Iron Holder
- Solder Wire
- Solder Sucker (for desoldering)
- Tweezers
- Diagonal Cutting Pliers
- Sharp-nose Pliers
- Screwdriver (various sizes)
- Multimeter (for testing)
- Sponge (for cleaning soldering iron tip)
4.2 Assembly Steps
- Identify Components: Carefully identify each component using the provided component list (Image 2.1) and the markings on the PCB (Image 4.1). Pay attention to resistor values, capacitor polarities (for electrolytic capacitor C5), and transistor types (S9012, S9018).
- Solder Resistors: Start by soldering the resistors (R1, R2, R3, VR1) into their designated positions on the PCB. Resistors are not polarized.
- Solder Capacitors: Solder the ceramic capacitors (C1, C2, C3, C4). These are not polarized. For the electrolytic capacitor (C5), ensure correct polarity; the longer lead is typically positive (+), and the shorter lead or marked side is negative (-). Match this with the PCB markings.
- Solder Transistors: Solder the transistors (Q1, Q2, Q3). Ensure their flat side or pin configuration matches the outline on the PCB.
- Solder LED: Solder the LED (LED1). LEDs are polarized; the longer lead is positive (+), and the shorter lead is negative (-). Match with PCB markings.
- Solder Buzzer: Solder the buzzer (SP1). Some buzzers are polarized; check for markings on the buzzer and PCB.
- Solder Power Switch and Socket: Solder the power switch (SW1) and the power socket (J1) into their respective positions.
- Inspect Solder Joints: After soldering all components, carefully inspect all solder joints for cold joints, bridges, or poor connections. Ensure all components are securely attached and correctly oriented.

Image 4.1: Top view of the MDS-60 Printed Circuit Board (PCB), showing component placement outlines and labels for assembly reference.

Image 4.2: Bottom view of the MDS-60 PCB, illustrating the solder pads and traces for component connections.
5. Setup and Wiring
Once the kit is fully assembled, connect a DC power source to the module.
5.1 Power Connection
- The module requires a DC power input between 3V and 5V.
- Connect the positive (+) terminal of your power supply to the `+DC3-5V` terminal on the module's power socket (J1).
- Connect the negative (-) terminal (ground) of your power supply to the `-` terminal on the module's power socket (J1).
- An optional battery box for 3x AA 1.5V batteries (total 4.5V) can be used as a portable power source.

Image 5.1: Close-up view of the assembled MDS-60 module, highlighting the power input terminals (+DC3-5V-) and the power switch (SW1).
6. Operation
After successful assembly and power connection, the metal detector is ready for operation.
6.1 Power On
Toggle the power switch (SW1) to the 'ON' position. The LED (LED1) may illuminate briefly, and the buzzer (SP1) might emit a short sound as the circuit stabilizes.
6.2 Sensitivity Adjustment
The module features an adjustable resistor (VR1) which can be used to fine-tune the detection sensitivity. Use a small screwdriver to carefully turn VR1. Adjusting this potentiometer will change the detection range and the threshold at which the alarm activates.
6.3 Metal Detection
Move the circular coil part of the module near metallic objects. When a metal object is detected within the 60mm range, the LED (LED1) will light up, and the buzzer (SP1) will emit an audible alarm.
7. Applications
The DONGKER MDS-60 DIY Metal Detector Kit can be utilized in various educational and practical scenarios:
- Game entertainment projects
- Basic security checks
- Searching for small metal products
- Car detection systems
- Traffic statistics applications
- Elevator floor control systems
- Production equipment position detection
- Development and design of production equipment
- Electronic product design projects
- Development of play equipment
- Metal proximity switch applications
- Basic metal detection in human body (e.g., for educational purposes)
8. Troubleshooting
If the metal detector does not function as expected, consider the following:
- No Power/No Indication:
- Check power supply connections and ensure the voltage is within DC 3-5V.
- Verify the power switch (SW1) is in the 'ON' position.
- Inspect all solder joints for continuity and proper connection using a multimeter.
- Ensure the LED (LED1) is correctly oriented and not damaged.
- No Detection/Constant Alarm:
- Adjust the sensitivity potentiometer (VR1) to calibrate the detection threshold.
- Ensure all components, especially transistors and capacitors, are correctly oriented and not damaged.
- Check for any short circuits or open circuits on the PCB.
- Weak Detection:
- Increase the sensitivity by adjusting VR1.
- Ensure the power supply is stable and providing adequate current.
9. Maintenance
To ensure the longevity and proper functioning of your DONGKER MDS-60 module:
- Keep the module clean and free from dust and debris.
- Avoid exposing the module to moisture or extreme temperatures.
- Handle the PCB and components with care to prevent physical damage.
- Store in a dry, cool environment when not in use.
10. Support
For further assistance or inquiries regarding the DONGKER MDS-60 DIY Metal Detector Kit, please refer to the seller or manufacturer's official support channels.