EASYLONGER ES400 AIR

EASYLONGER ES400 AIR CPAP Battery User Manual

Model: ES400 AIR (GP48 AIR)

1. Introduction

Thank you for choosing the EASYLONGER ES400 AIR CPAP Battery. This portable power supply is designed to provide reliable and uninterrupted power for your CPAP machine and other electronic devices, whether you are camping, traveling, or experiencing a power outage. With its 148Wh capacity and multiple output ports, the ES400 AIR ensures you can maintain your therapy and stay connected wherever you are. This manual provides essential information for the safe and efficient use of your device.

2. Safety Information

Please read all safety instructions carefully before using the EASYLONGER ES400 AIR. Failure to follow these instructions may result in electric shock, fire, or serious injury.

3. Package Contents

Verify that all items are present in your package:

4. Product Overview

EASYLONGER ES400 AIR CPAP Battery showing its ports and display

Figure 4.1: Front view of the EASYLONGER ES400 AIR CPAP Battery, highlighting the DC IN/OUT, USB-C OUT, USB-A OUT ports, and the digital display.

The EASYLONGER ES400 AIR is a compact and robust power bank designed for portability and durability. It features a clear digital display showing output voltage and battery percentage. The device includes multiple output ports to accommodate various devices:

5. Setup

Before first use, fully charge your EASYLONGER ES400 AIR battery.

5.1 Initial Charging

Connect the included AC adapter to the DC IN/OUT port on the battery and plug it into a wall outlet. The digital display will show the charging progress. A full charge typically takes 4-5 hours.

5.2 Connecting to CPAP Machine

Four different CPAP cables included with the battery, showing compatibility with ResMed AirMini, AirSense 10, AirSense 11, AirCurve 10, DreamStation 2, Dreamstation, and ResMed S9.

Figure 5.1: Included CPAP cables for various machine models.

Diagram showing three methods to power a CPAP machine: direct DC connection, cigarette lighter cable with voltage converter, and inverter connection.

Figure 5.2: Options for powering your CPAP machine.

The ES400 AIR comes with 4 specific DC cables for direct connection to popular CPAP models. Before connecting, ensure the correct voltage is selected on the battery to match your CPAP machine's requirements (12V, 16.5V, 20V, or 24V). Refer to your CPAP machine's manual for its specific voltage.

  1. Direct Connection (Recommended): Use one of the included DC cables that matches your CPAP machine. Connect one end to the battery's DC IN/OUT port and the other to your CPAP machine.
  2. Using a Cigarette Lighter Cable with a Voltage Converter (Sold Separately): For CPAP machines not directly supported by the included cables, you may use a cigarette lighter cable with an appropriate voltage converter connected to the battery's DC 12V OUT (car socket) port.
  3. Using an Inverter (Sold Separately): For broader compatibility, an AC inverter can be connected to the battery's DC 12V OUT (car socket) port, allowing you to power your CPAP machine using its standard AC adapter. Note that using an inverter can decrease overall runtime due to energy conversion loss.

6. Operating

6.1 Powering On/Off

Press and hold the power button for a few seconds to turn the unit on or off. The digital display will illuminate, showing the battery level and output voltage.

6.2 Using Output Ports

6.3 Pass-Through Charging

A CPAP battery connected to a wall outlet for charging while simultaneously powering a CPAP machine, demonstrating pass-through charging.

Figure 6.1: Pass-Through Charging in action.

The ES400 AIR supports pass-through charging, allowing you to charge the battery while simultaneously powering your CPAP machine or other devices. This feature ensures uninterrupted power, acting as a backup power supply in case of a power outage. For CPAP machines, this functionality works directly with the included DC cables. If using a voltage converter or inverter, ensure they also support pass-through functionality.

7. Charging Options

Diagram showing three ways to recharge the CPAP battery: AC adapter, car outlet, and solar panel.

Figure 7.1: Three recharging options for the ES400 AIR.

Your EASYLONGER ES400 AIR offers versatile recharging methods:

8. Compatibility & Runtime

8.1 CPAP Machine Compatibility

Image showing the EASYLONGER ES400 AIR battery connected to various CPAP machines via included DC cables, indicating compatibility with ResMed AirSense 11, AirCurve 11, AirMini, AirSense 10, AirCurve 10, DreamStation 2, DreamStation, and ResMed S9.

Figure 8.1: Direct compatibility with included cables.

Image showing the EASYLONGER ES400 AIR battery with an inverter, indicating compatibility with a wide range of CPAP models including F&P SleepStyle Auto CPAP, iBreeze Series, Lowenstein Prisma 20A Auto, Prisma SMART, Breas Z2 Travel, iSleep 25, XT Fit/Auto CPAP Machine, Sefam S.Box CPAP, Transcend 3 Auto, Luna G3, Luna TravelPAP, and Curasa Auto.

Figure 8.2: Broad compatibility with an inverter (sold separately).

The ES400 AIR is designed to be compatible with most CPAP machines on the market. The included DC cables provide direct compatibility with:

For other CPAP models, compatibility can be achieved using a separate voltage converter or an AC inverter connected to the battery's 12V car socket output.

8.2 Factors Affecting Runtime

Comparison of CPAP runtime for AirSense 11: 12 hours with humidifier and heated tube OFF, versus 4 hours with them ON.

Figure 8.3: Impact of humidifier and heated tube on runtime.

List of factors affecting CPAP battery duration, including humidifier, ramp up function, altitude compensation, machine type, pressure relief, patient's breathing pattern, mask leaks, automatic leak compensator, Bluetooth/App/Wifi, Smart Start/Stop, and Therapy Mode.

Figure 8.4: Comprehensive list of factors affecting battery duration.

The actual runtime of the ES400 AIR when powering a CPAP machine can vary significantly based on several factors:

Estimated Runtimes (Humidification and Heating OFF, Ambient Temperature: 25°C / 77°F):

CPAP ModelPressure (cm H₂O)Estimated Run Time
ResMed AirMini818 hrs
ResMed AirMini1216 hrs
ResMed AirMini1612 hrs
AirSense 116-814 hrs
AirSense 1110-1212 hrs
AirSense 1114-169 hrs
AirSense 106-814 hrs
AirSense 1010-1212 hrs
AirSense 1014-169 hrs
DreamStation 2815 hrs
DreamStation 21213 hrs
DreamStation 2169 hrs

9. Maintenance

Proper maintenance ensures the longevity and optimal performance of your EASYLONGER ES400 AIR battery.

10. Troubleshooting

If you encounter issues with your EASYLONGER ES400 AIR, refer to the following common troubleshooting steps:

ProblemPossible CauseSolution
Battery not chargingAC adapter not connected properly; Faulty adapter or cable; Battery too hot/cold.Ensure all connections are secure. Try a different outlet. Allow battery to reach room temperature. Contact support if issue persists.
Device not powering CPAPIncorrect voltage setting; Incorrect DC cable used; CPAP machine power requirements too high (e.g., humidifier ON); Battery discharged.Verify the voltage setting matches your CPAP. Ensure the correct DC cable is used. Turn off humidifier/heated tube. Recharge the battery.
Short runtimeHumidifier/heated tube ON; High CPAP pressure; Mask leaks; Using an inverter.Turn off humidifier/heated tube. Check for mask leaks. Consider direct DC connection instead of inverter.
USB ports not workingDevice not powered on; Cable issue; Device not compatible.Ensure the battery is powered on. Try a different USB cable. Check device compatibility with USB-C PD or USB-A.

For more detailed troubleshooting or issues not listed here, please refer to the full User Manual PDF available online or contact EASYLONGER customer support.

11. Specifications

FeatureDetail
Model NumberGP48 AIR (ES400 AIR)
Battery TypeLithium Ion
Capacity148Wh / 40000mAh
Product Dimensions7.28 x 4.76 x 1.57 inches
Item Weight2.05 pounds
DC IN/OUT Voltage12V, 16.5V, 20V, 24V (3.5A)
USB-C Output30W Power Delivery (PD) Max
USB-A Output18W Power Delivery (PD) Max
DC 12V OUT (Car Socket)160W Max
Recharge Time (AC Adapter)4-5 hours
Recharge Time (Car Charger)2-3 hours
Recharge Time (Solar Panel)3-4 hours (with 80W panel)
Special FeaturesTravel, Over Voltage Protection, Fast Charging, Built-in BMS
ManufacturerDongguan Yihang Electronic Co., Ltd
Date First AvailableMay 9, 2023

12. Warranty and Support

EASYLONGER products are manufactured with high-quality materials and undergo rigorous testing. For warranty information and customer support, please refer to the warranty card included in your package or visit the official EASYLONGER website. If you have any questions or require assistance, do not hesitate to contact our customer service team.

Online Resources:

Related Documents - ES400 AIR

Preview EASYLONGER ES960 CPAP Battery Backup Power Supply User Manual
User manual for the EASYLONGER ES960 CPAP Battery Backup Power Supply, offering 297.6Wh capacity for AirSense, AirCurve, AirMini, and DreamStation devices. Ideal for emergency power and outdoor use.
Preview EASYLONGER E8400 AIR CPAP Battery Backup User Manual
User manual for the EASYLONGER E8400 AIR CPAP Battery Backup, detailing its features, usage, and specifications for powering CPAP machines and other devices.
Preview EASYLONGER EL240 Laptop Power Bank User Manual
User manual for the EASYLONGER EL240 Laptop Power Bank, detailing its specifications, features, charging instructions for laptops, CPAPs, and other devices, as well as troubleshooting and warranty information.
Preview EASYLONGER ES400 AIR Portable Power Station User Manual
User manual for the EASYLONGER ES400 AIR portable power station, detailing its specifications, package contents, charging methods, usage instructions for various ports (USB, USB-C, DC, 12V cigar lighter), part identification, usage notes, FAQs, and warranty information.
Preview ES960 PRO CPAP Battery Backup User Manual
User manual for the EASYLONGER ES960 PRO CPAP Battery Backup, detailing safety information, product overview, specifications, operation instructions, charging methods, CPAP usage, troubleshooting, maintenance, and warranty.
Preview EASYLONGER ES720 PRO CPAP Battery Backup User Manual
Comprehensive user manual for the EASYLONGER ES720 PRO CPAP battery backup, detailing safety information, product specifications, operation instructions, charging methods, CPAP compatibility, usage scenarios, troubleshooting, maintenance, and warranty.