1. Important Safety Instructions

Please read this manual carefully before operating your Orbegozo ADR 127 Portable Air Conditioner. Keep this manual for future reference.

  • Ensure the unit is placed on a stable, level surface.
  • Do not block air inlets or outlets. Maintain at least 20 cm clearance from walls and other objects.
  • Do not operate the unit with a damaged cord or plug.
  • Do not insert objects into the air vents.
  • Unplug the unit before cleaning or maintenance.
  • This appliance uses R290 refrigerant. Do not puncture the refrigerant circuit.
  • Keep children and pets away from the unit during operation.
  • Do not use the unit in wet environments or near water.

2. Product Overview

The Orbegozo ADR 127 is a versatile portable air conditioner designed for cooling, heating, ventilation, and dehumidification. It features a compact design with castor wheels for easy mobility and a user-friendly control panel.

Key Features:

  • Cooling Capacity: 3000 frigories/hour (1400W consumption)
  • Heating Capacity: 2400 kilocalories/hour (1300W consumption)
  • Energy Class: A
  • Environmentally friendly R290 refrigerant
  • Four operating modes: Cool, Heat, Fan, Dehumidify
  • Dehumidification Capacity: 72 liters/day
  • 3 fan speeds
  • Temperature range: 16 °C to 32 °C (or °F)
  • 24-hour ON/OFF timer
  • Remote control included
  • Pivoting castor wheels for easy movement
  • Directional louvers with full closure option
  • Full water tank indicator
  • Drain connection for continuous drainage
  • Airflow: 480 m³/h

Components:

Orbegozo ADR 127 Portable Air Conditioner front view

Figure 2.1: Front and side view of the Orbegozo ADR 127 Portable Air Conditioner, showcasing its compact white design and the Orbegozo logo.

Orbegozo ADR 127 Portable Air Conditioner side view with exhaust port

Figure 2.2: Side view of the unit, highlighting the exhaust air outlet connection point for the hot air duct.

Orbegozo ADR 127 Portable Air Conditioner top control panel

Figure 2.3: Top view of the control panel, showing the various buttons for mode selection, fan speed, timer, and temperature adjustment, along with indicator lights.

3. Setup and Installation

Proper setup is crucial for optimal performance and safety.

  1. Unpacking: Carefully remove the unit from its packaging. Retain packaging for future storage or transport.
  2. Placement: Place the air conditioner on a firm, level surface. Ensure there is at least 20 cm of space around the unit for proper airflow. Avoid direct sunlight.
  3. Exhaust Hose Installation:
    • Attach the exhaust hose connector to the air outlet on the back of the unit.
    • Extend the exhaust hose and connect the window kit adapter to the other end.
    • Install the window kit in a suitable window opening, ensuring a tight seal to prevent hot air from re-entering the room.
  4. Drainage Connection (Optional for continuous drainage): For continuous dehumidification or cooling in high humidity, connect a drain hose (not included) to the continuous drain port at the back of the unit and direct it to a suitable drain or container.
  5. Power Connection: Plug the power cord into a grounded 230V ~ 50 Hz electrical outlet.

4. Operating Instructions

The unit can be operated via the control panel on top of the unit or the included remote control.

Control Panel / Remote Control Functions:

  • Power Button (): Turns the unit ON or OFF.
  • Mode Button (): Cycles through operating modes: Cool, Heat, Fan, Dehumidify.
  • Fan Speed Button (): Adjusts fan speed (Low, Medium, High).
  • Temperature Up/Down Buttons ( / ): Adjusts the desired temperature (16°C - 32°C).
  • Timer Button (): Sets the 24-hour ON/OFF timer. Press to set the desired time increment.
  • Sleep Mode: (If available on remote) Activates a quiet operation mode for comfortable sleep.
  • Swing Function: (If available on remote) Activates automatic louver swing for wider air distribution.

Operating Modes:

  • Cool Mode: For cooling the room. Set desired temperature and fan speed.
  • Heat Mode: For heating the room. Set desired temperature and fan speed.
  • Fan Mode: Circulates air without cooling or heating. Select desired fan speed.
  • Dehumidify Mode: Removes excess moisture from the air. The fan speed is typically fixed in this mode. Ensure continuous drainage is set up or empty the water tank regularly.

5. Maintenance

Regular maintenance ensures efficient operation and extends the lifespan of your unit.

  • Cleaning the Air Filter:
    • The air filter should be cleaned every two weeks or more frequently depending on usage.
    • Unplug the unit.
    • Remove the filter from the back of the unit.
    • Wash the filter with warm, soapy water. Rinse thoroughly and allow to air dry completely before reinserting.
  • Draining the Water Tank:
    • When the "Full Water Tank" indicator lights up, the unit will stop operating.
    • Unplug the unit.
    • Place a shallow pan or tray under the drain port at the bottom rear of the unit.
    • Remove the drain plug and allow all water to drain out.
    • Replace the drain plug firmly.
  • Cleaning the Unit Exterior: Wipe the exterior with a soft, damp cloth. Do not use harsh chemicals or abrasive cleaners.
  • Storage: Before long-term storage, drain all water, clean the filter, and allow the unit to run in fan mode for a few hours to dry the internal components. Store in a dry, cool place, preferably in its original packaging.

6. Troubleshooting

Refer to this section for common issues and their solutions.

ProblemPossible CauseSolution
Unit does not turn on.No power; power cord unplugged; circuit breaker tripped.Check power connection; reset circuit breaker.
Unit runs but does not cool/heat.Window kit not properly sealed; room too large; air filter dirty; temperature setting too high/low.Ensure window kit is sealed; clean air filter; adjust temperature setting.
Water tank full indicator is on.Water tank is full.Drain the water tank as per maintenance instructions.
Unit is noisy.Unit not on a level surface; fan obstruction.Place on a level surface; check for obstructions in fan area.

If the problem persists after attempting these solutions, please contact customer support.

7. Specifications

ParameterValue
Model NumberADR 127
Cooling Capacity3000 frigories/hour
Heating Capacity2400 kilocalories/hour
Cooling Power Consumption1400 W
Heating Power Consumption1300 W
Energy ClassA
RefrigerantR290
Dehumidification Capacity72 liters/day
Airflow480 m³/h
Temperature Range16 °C to 32 °C
Noise Level52 – 54 dB
Dimensions (W x H x D)45.5 x 74.5 x 39.5 cm
Power Supply230V ~ 50 Hz

8. Warranty and Customer Support

Orbegozo products are manufactured to high quality standards. In the unlikely event of a defect, please refer to your purchase receipt for warranty terms and conditions.