AOPUTTRIVER T4-1013D-E

AOPUTTRIVER 1013D Plus Oscilloscope User Manual

Model: T4-1013D-E

Comprehensive Guide for Operation and Maintenance

1. Introduction

Thank you for choosing the AOPUTTRIVER 1013D Plus Oscilloscope. This portable handheld tablet oscilloscope is designed for a wide range of applications, from electronic production and home appliance repair to scientific research and product development. Featuring a 7-inch TFT LCD touch screen, 100MHz bandwidth, and 1GSa/s sampling rate, it offers powerful functionality in a compact form factor.

This manual provides detailed instructions for the proper setup, operation, and maintenance of your oscilloscope. Please read this manual thoroughly before using the device to ensure safe and efficient operation.

2. Safety Information

Always observe the following safety precautions to prevent injury and avoid damage to the instrument or other devices connected to it.

Intelligent anti-burning feature of the oscilloscope

Image: The oscilloscope's intelligent anti-burning feature, highlighting its built-in high-voltage protection module that tolerates up to 400V continuous voltage input.

3. Product Overview and Features

The AOPUTTRIVER 1013D Plus is a versatile and portable oscilloscope designed for precision measurements. Key features include:

AOPUTTRIVER 1013D Plus Oscilloscope with touch screen interface

Image: The AOPUTTRIVER 1013D Plus Oscilloscope displaying waveforms on its 7-inch touch screen, with a hand interacting with the interface.

Close-up of the oscilloscope's touch screen functionality

Image: A close-up view of the oscilloscope's touch screen, demonstrating its flat panel design and dual-channel display capabilities.

4. Specifications

The following table details the technical specifications of the AOPUTTRIVER 1013D Plus Oscilloscope:

ParameterValueParameterValue
Channels2CursorPosition XY Trigger Y
Display7inch 800*480 pixelsRoll modeSupport
Bandwidth100MHzOne-Button AUTOSupport
Sampling Rate1GSa/sWaveform Storage1000 Picture + 1000 Waveform
Rise time<3nSWaveform ManagerSupport
Storage Depth240 KbitVoltage Accuracy±2%
Input Resistance1MΩFrequency Precision+0.01% High Precision
Sensitivity50mV~500VParameter12 Kinds in Total
Time Base50S~10nSBattery6000mAh Lithium
Trigger ModeSingle/Normal/AutoStandby4 Hours
Trigger EdgeRising/FallingExtensionUSB Export
CouplingAC/DCChargingType-C 5V 2A/3A/4A
Highest Test Voltage1X:40V 10X:400V
Oscilloscope dimensions and detailed specifications table

Image: Physical dimensions of the oscilloscope and a comprehensive table of its technical specifications.

5. Setup

5.1 Unboxing and Package Contents

Carefully unpack all components and verify that all items listed below are present and undamaged. If any items are missing or damaged, please contact customer support.

Contents of the AOPUTTRIVER 1013D Plus Oscilloscope package

Image: A visual representation of the items included in the product package, such as the oscilloscope, probes, USB cable, charger, and user manual.

5.2 Initial Charging

Before first use, it is recommended to fully charge the oscilloscope's built-in 6000mAh lithium battery. Connect the provided Type-C USB cable to the oscilloscope's charging port and the 5V2A charger to a power outlet. The charging indicator will show the charging status.

5.3 Probe Connection

Connect the oscilloscope probes to the input channels (CH1, CH2) on the device. Ensure a secure connection. For accurate measurements, calibrate the probes as described in the operating instructions section.

6. Operating Instructions

6.1 Power On/Off

To power on the oscilloscope, press and hold the power button located on the side/top of the device until the screen illuminates. To power off, press and hold the power button again until the device shuts down.

6.2 Navigating the Touch Screen Interface

The 1013D Plus features an intuitive touch screen interface. Most functions and settings can be accessed by tapping icons and menus directly on the screen. Use gestures like swiping to navigate through menus or adjust waveform positions.

6.3 Waveform Display and Adjustment

Upon powering on, the oscilloscope will display real-time waveforms. You can adjust various parameters to optimize the display:

6.4 Data Storage and Management

The oscilloscope allows for convenient storage of waveforms and screenshots:

Data waveform storage capability of the oscilloscope

Image: Illustration of the oscilloscope's data waveform storage feature, showing its ability to store up to 1000 screenshots and 1000 sets of waveform data with a single tap.

6.5 Connecting to a Computer for Secondary Analysis

The oscilloscope is equipped with a USB interface, allowing you to connect it to a computer for further analysis of stored data. This feature is convenient for detailed examination and reporting.

Oscilloscope connected to a laptop for data sharing and analysis

Image: The oscilloscope connected to a laptop, demonstrating its capability for data sharing and secondary analysis of captured waveforms and screenshots.

7. Maintenance

7.1 Cleaning the Device

To clean the oscilloscope, first ensure it is powered off and disconnected from all power sources and probes. Use a soft, lint-free, slightly damp cloth to wipe the exterior. Do not use harsh chemicals, abrasive cleaners, or solvents, as these can damage the screen or casing.

7.2 Battery Care and Storage

To prolong the life of the built-in lithium battery:

8. Troubleshooting

This section addresses common issues you might encounter with your AOPUTTRIVER 1013D Plus Oscilloscope. If you experience a problem not listed here, or if the suggested solutions do not resolve the issue, please contact customer support.

ProblemPossible CauseSolution
Device does not power on.Battery is depleted; Power button not pressed correctly.Charge the battery using the provided charger and USB cable. Ensure the power button is pressed and held until the screen illuminates.
No waveform displayed.Probe not connected; Input signal too small or too large; Trigger settings incorrect.Verify probe connections. Adjust vertical scale (V/div) and horizontal scale (Time/div). Check trigger mode and level settings, try "One-Button Auto".
Waveform is unstable or rolling.Trigger level or mode is incorrect; Input signal is noisy.Adjust the trigger level. Try different trigger modes (Normal for stable signals). Ensure proper grounding and minimize noise in the test environment.
Touch screen unresponsive.Temporary software glitch; Screen dirty.Restart the device. Clean the screen with a soft, dry cloth.
Cannot save data.Storage space full; Software error.Delete old data to free up space. Restart the device.

9. Warranty and Support

AOPUTTRIVER stands behind the quality of its products. This oscilloscope is covered by a manufacturer's warranty against defects in materials and workmanship. For specific warranty terms and conditions, please refer to the warranty card included in your package or contact AOPUTTRIVER customer support.

If you have any questions, require technical assistance, or need to arrange for a refund or replacement, please feel free to contact AOPUTTRIVER customer service. Contact information can typically be found on the manufacturer's official website or through your point of purchase.

Related Documents - T4-1013D-E

Preview 7200APP DC/AC True-RMS Digital Clamp Multimeter User Manual
User manual for the AOPUTTRIVER 7200APP DC/AC True-RMS Digital Clamp Multimeter. This auto-ranging, 6000-count meter measures amperage, voltage, capacitance, continuity, and resistance, featuring Bluetooth connectivity via the AILink app. Includes safety, operation, and maintenance details.
Preview 6000 Counts True-RMS Auto Range Intelligent Digital AC/DC Clamp Multimeter Operation Manual
This document provides the operation manual for the AOPUTTRIVER 6000 Counts True-RMS Auto Range Intelligent Digital AC/DC Clamp Multimeter (Model AP-570S-APP), detailing its features, specifications, operating instructions, and companion AiLink mobile application.
Preview Quick Start Guide - AOPUTTRIVER Infrared Thermometer AP-2732
Get started quickly with your AOPUTTRIVER Infrared Thermometer (AP-2732). This guide covers battery installation, basic operation, and understanding the display readings for models like the AP-2732.
Preview AOPUTTRIVER AP-570C-APP Bluetooth Connection Guide
Step-by-step instructions for connecting the AOPUTTRIVER AP-570C-APP clamp meter to your smartphone via Bluetooth. Includes troubleshooting tips for a seamless setup.
Preview AOPUTTRIVER AR8500 Ammonia Gas Detector User Manual and Technical Specifications
Comprehensive instruction manual for the AOPUTTRIVER AR8500 Ammonia Gas Detector. Covers product description, technical parameters, operation, maintenance, and safety precautions for this precision measurement apparatus.
Preview FNIRSI 1013D: Dvoukanálový digitální osciloskop s 7" dotykovým TFT LCD displejem – Návod k obsluze
Uživatelská příručka pro digitální dvoukanálový osciloskop FNIRSI 1013D. Tento přenosný tablet osciloskop nabízí 100 MHz šířku pásma, 1 GSa/s vzorkovací frekvenci a 7" dotykový TFT LCD displej pro snadné a přesné měření v terénu i v laboratoři.