1. Introduction
Thank you for choosing the AOPUTTRIVER 1013D Plus Oscilloscope. This portable handheld tablet oscilloscope is designed for a wide range of applications, from electronic production and home appliance repair to scientific research and product development. Featuring a 7-inch TFT LCD touch screen, 100MHz bandwidth, and 1GSa/s sampling rate, it offers powerful functionality in a compact form factor.
This manual provides detailed instructions for the proper setup, operation, and maintenance of your oscilloscope. Please read this manual thoroughly before using the device to ensure safe and efficient operation.
2. Safety Information
Always observe the following safety precautions to prevent injury and avoid damage to the instrument or other devices connected to it.
- Power Source: Use only the specified power adapter and USB cable provided with the device.
- High Voltage Protection: The oscilloscope features a built-in high voltage protection module, capable of withstanding up to 400V continuous voltage. However, always exercise extreme caution when working with high voltages. Do not exceed the maximum input voltage ratings.
- Probe Usage: Ensure probes are correctly connected and rated for the voltage being measured. Use the 100X high voltage probe for high voltage measurements.
- Environment: Operate the device in a dry, well-ventilated area. Avoid exposure to moisture, dust, and extreme temperatures.
- Maintenance: Do not attempt to open or repair the device yourself. Refer all servicing to qualified personnel.
- Cleaning: Disconnect power before cleaning. Use a soft, dry cloth. Do not use abrasive cleaners or solvents.

Image: The oscilloscope's intelligent anti-burning feature, highlighting its built-in high-voltage protection module that tolerates up to 400V continuous voltage input.
3. Product Overview and Features
The AOPUTTRIVER 1013D Plus is a versatile and portable oscilloscope designed for precision measurements. Key features include:
- Display: 7-inch color TFT LCD touch screen with 800x480 resolution, offering bright colors and high contrast for clear waveform display.
- Performance: 2 channels, 100MHz analog bandwidth, and a real-time sampling rate of up to 1GSa/s.
- Triggering: Full range of triggering functions (single/normal/automatic) suitable for both periodic analog and non-periodic digital signals.
- Signal Generator: Built-in DDS signal generator supporting 12 kinds of function signals.
- Data Storage: Built-in 1GB storage space, capable of storing up to 1000 screenshots and 1000 sets of waveform data.
- Connectivity: USB interface for connection to a computer for secondary analysis and data sharing.
- Portability: Slim, compact, and easy to carry, powered by a 6000mAh lithium battery for up to 4 hours of standby time.

Image: The AOPUTTRIVER 1013D Plus Oscilloscope displaying waveforms on its 7-inch touch screen, with a hand interacting with the interface.

Image: A close-up view of the oscilloscope's touch screen, demonstrating its flat panel design and dual-channel display capabilities.
4. Specifications
The following table details the technical specifications of the AOPUTTRIVER 1013D Plus Oscilloscope:
| Parameter | Value | Parameter | Value |
|---|---|---|---|
| Channels | 2 | Cursor | Position XY Trigger Y |
| Display | 7inch 800*480 pixels | Roll mode | Support |
| Bandwidth | 100MHz | One-Button AUTO | Support |
| Sampling Rate | 1GSa/s | Waveform Storage | 1000 Picture + 1000 Waveform |
| Rise time | <3nS | Waveform Manager | Support |
| Storage Depth | 240 Kbit | Voltage Accuracy | ±2% |
| Input Resistance | 1MΩ | Frequency Precision | +0.01% High Precision |
| Sensitivity | 50mV~500V | Parameter | 12 Kinds in Total |
| Time Base | 50S~10nS | Battery | 6000mAh Lithium |
| Trigger Mode | Single/Normal/Auto | Standby | 4 Hours |
| Trigger Edge | Rising/Falling | Extension | USB Export |
| Coupling | AC/DC | Charging | Type-C 5V 2A/3A/4A |
| Highest Test Voltage | 1X:40V 10X:400V |

Image: Physical dimensions of the oscilloscope and a comprehensive table of its technical specifications.
5. Setup
5.1 Unboxing and Package Contents
Carefully unpack all components and verify that all items listed below are present and undamaged. If any items are missing or damaged, please contact customer support.
- T4-1013D-E Pro Oscilloscope (x1)
- Matching Probe (x2)
- Type-C USB Cable (x1)
- 5V2A Charger (x1)
- User Manual (x1)

Image: A visual representation of the items included in the product package, such as the oscilloscope, probes, USB cable, charger, and user manual.
5.2 Initial Charging
Before first use, it is recommended to fully charge the oscilloscope's built-in 6000mAh lithium battery. Connect the provided Type-C USB cable to the oscilloscope's charging port and the 5V2A charger to a power outlet. The charging indicator will show the charging status.
5.3 Probe Connection
Connect the oscilloscope probes to the input channels (CH1, CH2) on the device. Ensure a secure connection. For accurate measurements, calibrate the probes as described in the operating instructions section.
6. Operating Instructions
6.1 Power On/Off
To power on the oscilloscope, press and hold the power button located on the side/top of the device until the screen illuminates. To power off, press and hold the power button again until the device shuts down.
6.2 Navigating the Touch Screen Interface
The 1013D Plus features an intuitive touch screen interface. Most functions and settings can be accessed by tapping icons and menus directly on the screen. Use gestures like swiping to navigate through menus or adjust waveform positions.
6.3 Waveform Display and Adjustment
Upon powering on, the oscilloscope will display real-time waveforms. You can adjust various parameters to optimize the display:
- Vertical Scale (V/div): Adjust the voltage per division for each channel to fit the waveform vertically on the screen.
- Horizontal Scale (Time/div): Adjust the time per division to control the horizontal spread of the waveform.
- Trigger Settings:
- Mode: Select between Auto, Normal, or Single trigger modes. Auto mode is suitable for most signals, Normal for stable displays of repetitive signals, and Single for capturing single-shot events.
- Edge: Set the trigger to rising or falling edge.
- Level: Adjust the trigger level to stabilize the waveform display.
- One-Button Auto: Utilize the efficient one-touch automatic device function to quickly display the measurement waveform without tedious manual adjustments.
6.4 Data Storage and Management
The oscilloscope allows for convenient storage of waveforms and screenshots:
- Save Waveform/Screenshot: Use the dedicated "Save Pic" or "Save Wave" functions on the touch screen to store data with one click.
- Waveform Image Manager: Access the powerful waveform image manager to browse, view, zoom, move, and delete stored data.

Image: Illustration of the oscilloscope's data waveform storage feature, showing its ability to store up to 1000 screenshots and 1000 sets of waveform data with a single tap.
6.5 Connecting to a Computer for Secondary Analysis
The oscilloscope is equipped with a USB interface, allowing you to connect it to a computer for further analysis of stored data. This feature is convenient for detailed examination and reporting.

Image: The oscilloscope connected to a laptop, demonstrating its capability for data sharing and secondary analysis of captured waveforms and screenshots.
7. Maintenance
7.1 Cleaning the Device
To clean the oscilloscope, first ensure it is powered off and disconnected from all power sources and probes. Use a soft, lint-free, slightly damp cloth to wipe the exterior. Do not use harsh chemicals, abrasive cleaners, or solvents, as these can damage the screen or casing.
7.2 Battery Care and Storage
To prolong the life of the built-in lithium battery:
- Avoid fully discharging the battery frequently.
- If storing the device for an extended period, charge the battery to approximately 50-70% before storage.
- Store the oscilloscope in a cool, dry place, away from direct sunlight and extreme temperatures.
8. Troubleshooting
This section addresses common issues you might encounter with your AOPUTTRIVER 1013D Plus Oscilloscope. If you experience a problem not listed here, or if the suggested solutions do not resolve the issue, please contact customer support.
| Problem | Possible Cause | Solution |
|---|---|---|
| Device does not power on. | Battery is depleted; Power button not pressed correctly. | Charge the battery using the provided charger and USB cable. Ensure the power button is pressed and held until the screen illuminates. |
| No waveform displayed. | Probe not connected; Input signal too small or too large; Trigger settings incorrect. | Verify probe connections. Adjust vertical scale (V/div) and horizontal scale (Time/div). Check trigger mode and level settings, try "One-Button Auto". |
| Waveform is unstable or rolling. | Trigger level or mode is incorrect; Input signal is noisy. | Adjust the trigger level. Try different trigger modes (Normal for stable signals). Ensure proper grounding and minimize noise in the test environment. |
| Touch screen unresponsive. | Temporary software glitch; Screen dirty. | Restart the device. Clean the screen with a soft, dry cloth. |
| Cannot save data. | Storage space full; Software error. | Delete old data to free up space. Restart the device. |
9. Warranty and Support
AOPUTTRIVER stands behind the quality of its products. This oscilloscope is covered by a manufacturer's warranty against defects in materials and workmanship. For specific warranty terms and conditions, please refer to the warranty card included in your package or contact AOPUTTRIVER customer support.
If you have any questions, require technical assistance, or need to arrange for a refund or replacement, please feel free to contact AOPUTTRIVER customer service. Contact information can typically be found on the manufacturer's official website or through your point of purchase.