1. Introduction
The Hoymiles HM-600N is a 2-in-1 microinverter designed to connect up to two solar panels, optimizing the photovoltaic (PV) energy production of your installation. This microinverter features a maximum DC voltage of 60V, classifying it as PV Rapid Shutdown Equipment. It complies with NEC-2017 and NEC-2020 Article 690.12, as well as CEC-2021 Sec 64-218, ensuring safety and regulatory adherence for solar energy systems.

Image 1.1: The Hoymiles HM-600N Microinverter, a compact device designed for converting DC power from solar panels into AC power for grid connection.
2. Safety Information
Please read all instructions and warnings carefully before installation and operation. Failure to follow these instructions may result in electric shock, fire, or serious injury. Keep this manual for future reference.
- Installation must be performed by qualified personnel.
- Do not attempt to repair the microinverter yourself. Contact qualified service personnel.
- Ensure all electrical connections are secure and properly insulated.
- Disconnect all power sources before servicing or installing the microinverter.
- Wear appropriate personal protective equipment (PPE) during installation.
- The microinverter is designed for outdoor use but should be protected from direct exposure to extreme weather conditions where possible.
3. Package Contents
Verify that all components are present and undamaged upon opening the package. The standard package for the HM-600N microinverter typically includes:
- Hoymiles HM-600N Microinverter unit
- Mounting bracket (pre-attached or separate)
- Necessary connectors for DC input and AC output
- User Manual (this document)

Image 3.1: Top view of the Hoymiles HM-600N Microinverter as it appears within its protective packaging, showing the main unit and attached cables.

Image 3.2: Bottom view of the Hoymiles HM-600N Microinverter within its packaging, highlighting the underside of the unit and cable routing.

Image 3.3: The shipping box for the Hoymiles HM-600N Microinverter, displaying product labels and handling instructions.
4. Setup and Installation
The HM-600N microinverter is designed for easy installation, often described as 'plug and play'. Follow these steps for proper setup:
4.1 Mounting the Microinverter
- Choose a suitable location under the PV module, ensuring adequate ventilation and protection from direct sunlight or extreme weather.
- Attach the microinverter to the PV module racking system using the integrated mounting bracket. Ensure it is securely fastened.
4.2 Electrical Connections
- DC Input: Connect the DC cables from up to two solar panels to the corresponding DC input ports on the microinverter. Ensure correct polarity (+ to + and - to -).
- AC Output: Connect the AC output cable of the microinverter to the AC branch circuit. For multiple microinverters, daisy-chain them according to local electrical codes and the system design.
- Grounding: Ensure the microinverter is properly grounded as per local electrical regulations.
The HM-600N is a PV Rapid Shutdown Equipment and conforms with NEC-2017 and NEC-2020 Article 690.12 and CEC-2021 Sec 64-218, which may require specific wiring practices for rapid shutdown functionality.

Image 4.1: A side view of the Hoymiles HM-600N Microinverter, illustrating the various cable connection points for DC input and AC output.

Image 4.2: An angled perspective of the Hoymiles HM-600N Microinverter, providing a comprehensive view of its design and connection interfaces.
5. Operating Instructions
Once installed and connected, the Hoymiles HM-600N microinverter operates automatically. It will begin converting DC power from your solar panels into AC power for your home or the grid as soon as sufficient sunlight is available.
- Automatic Operation: The microinverter automatically starts and stops based on the availability of DC power from the solar panels and the presence of grid power.
- Monitoring: For detailed performance monitoring, a Hoymiles DTU (Data Transfer Unit) and S-Miles Cloud platform are typically used (sold separately). These allow you to track energy production, system status, and troubleshoot remotely.
6. Maintenance
The Hoymiles HM-600N microinverter is designed for minimal maintenance. However, periodic checks can help ensure optimal performance and longevity:
- Visual Inspection: Periodically inspect the microinverter and all cables for any signs of damage, corrosion, or loose connections.
- Cleaning: If necessary, gently clean the exterior of the microinverter with a soft, damp cloth. Do not use harsh chemicals or abrasive materials. Ensure the unit is de-energized before cleaning.
- Ventilation: Ensure that the area around the microinverter remains clear to allow for proper airflow and heat dissipation.
7. Troubleshooting
If your microinverter is not performing as expected, consider the following common issues:
| Problem | Possible Cause | Solution |
|---|---|---|
| No power output | No sunlight; DC input disconnected; AC output disconnected; Grid outage | Wait for sunlight; Check DC connections; Check AC connections and circuit breaker; Verify grid power is active |
| Low power output | Shading on panels; Dirty panels; Faulty panel; High ambient temperature | Clear shading; Clean panels; Inspect panels; Ensure proper ventilation |
| Indicator light off/abnormal | No power to microinverter; Internal fault | Check all connections; If problem persists, contact Hoymiles support |
For issues not listed or if solutions do not resolve the problem, please contact Hoymiles technical support.
8. Technical Specifications
Detailed specifications for the Hoymiles HM-600N Microinverter:
| Parameter | Value |
|---|---|
| Model Name | HM-600N |
| Dimensions | 250 × 170 × 28mm |
| Peak Output Power | 600VA |
| Maximum Continuous Output Power | 590VA |
| Commonly Used Module Power | 240W to 405W+ |
| Max. Input Current | 2 × 11.5A |
| Max. Input Voltage | 60V |
| Number of Modules Connected | 2 |
| MPPT Voltage Range | 16V–60V |
| Number of MPPTs | 2 |
| Power Source | Solar Powered |
| Color | Silver |
9. Warranty and Support
Hoymiles products are manufactured to high-quality standards and come with a limited warranty. For specific warranty terms and conditions, please refer to the warranty card included with your product or visit the official Hoymiles website.