1. Introduction

The Cleiscry H807 DMX512 is a dedicated LED controller designed for stage lighting applications, capable of managing up to 1024 pixel points across three output ports. It is specifically engineered to interface with a DMX512 console, providing precise control over various addressable LED chips such as WS2811, WS2812B, WS2813, and WS2815. This manual provides essential information for the proper setup, operation, and maintenance of your H807 DMX512 controller.

Cleiscry H807 DMX512 LED Controller front view

Figure 1: Front view of the H807 DMX512 LED Controller, showing the DMX IN/OUT ports and power/status indicators.

2. Setup Instructions

Follow these steps to correctly set up your H807 DMX512 controller:

2.1 Power Connection

The H807 DMX512 controller requires a DC input voltage ranging from 5V to 24V. Ensure your power supply matches the requirements of your LED strips and the controller.

Cleiscry H807 DMX512 LED Controller top view with power input

Figure 2: Top view of the H807 DMX512 controller, showing the VCC, GND, and DAT output terminals.

2.2 DMX512 Console Connection

The H807 DMX512 controller is designed to operate exclusively with a DMX512 console. Connect your DMX master console to the DMX IN port on the controller. Use the DMX OUT port to daisy-chain to other DMX devices if needed.

Cleiscry H807 DMX512 LED Controller showing DMX IN and DMX OUT ports

Figure 3: Side view of the H807 DMX512 controller, highlighting the DMX IN and DMX OUT ports for console connection.

The DMX IN/OUT ports utilize RJ45 connectors. Ensure proper wiring according to the DMX512 standard. The pinout for the RJ45 connector is typically 1:D+, 2:D-, 3-6:NC, 7-8:GND.

Cleiscry H807 DMX512 LED Controller with DIP switches and DMX ports

Figure 4: View of the H807 DMX512 controller showing the DIP switches for address setting and the DMX ports.

2.3 Setting DMX Address

The H807 DMX512 controller occupies 13 DMX channels. Use the DIP switches on the device to set the starting DMX address for each controller. Refer to the DIP switch configuration table (not provided, typically found in a separate DMX address chart) for specific address settings.

2.4 LED Strip Connection

The controller features three output ports, each capable of controlling a maximum of 1024 pixels. All three ports output the same data. Connect your addressable LED strips (e.g., WS2811, WS2812B, WS2813, WS2815) to the VCC, GND, and DAT terminals. Ensure correct polarity and data line connection.

The H807DMX supports a wide range of LED driver chips, including but not limited to: TM1812, P943, P943S, P9411, P9412, P9883, TM1804, TM1809, UCS1903, UCS1909, UCS1912, WS2811, WS2812, WS2813, SM16703, SM16709, SM16712, INK1003.

Wiring diagram for H807 DMX512 controller with LED strips and power supplies

Figure 5: Example wiring diagram illustrating connections from the DMX master, H807 controller, power supplies, and multiple LED strips.

3. Operating Instructions

Once the H807 DMX512 controller is properly connected and powered, its operation is managed entirely through your DMX512 console. The controller acts as an interface, translating DMX signals into control signals for the connected pixel LED strips.

  1. Power On: Ensure all connections are secure, then apply power to the H807 controller and your LED strips. The PWR indicator on the controller should illuminate.
  2. DMX Signal: Send DMX signals from your DMX512 console to the H807 controller. The STA (Status) indicator may flash or change to indicate active DMX signal reception.
  3. Control: Use your DMX512 console to send commands for color, brightness, and patterns to the connected LED strips. The controller will interpret these commands based on its assigned DMX address and control the pixels accordingly.

Refer to your DMX512 console's manual for specific programming and control procedures.

4. Maintenance

The H807 DMX512 controller is designed for reliable operation with minimal maintenance. Follow these guidelines to ensure its longevity:

  • Cleaning: Keep the device clean and free from dust. Use a soft, dry cloth for cleaning. Do not use liquid cleaners or solvents.
  • Environment: Operate the controller within its specified operating temperature range (-20°C to 85°C). Avoid exposure to extreme humidity, direct sunlight, or corrosive environments.
  • Connections: Periodically check all wiring connections to ensure they are secure and free from damage.
  • Ventilation: Ensure adequate airflow around the controller to prevent overheating.

5. Troubleshooting

If you encounter issues with your H807 DMX512 controller, refer to the following common troubleshooting steps:

  • No Power:
    • Check the power supply connection and ensure it provides the correct DC voltage (5-24V).
    • Verify that the power outlet is functional.
  • LEDs Not Responding:
    • Confirm that the DMX512 console is sending signals and is properly connected to the DMX IN port.
    • Check the DMX address setting on the H807 controller using the DIP switches. Ensure it matches the address configured on your DMX console.
    • Verify the wiring between the controller and the LED strips (VCC, GND, DAT). Ensure correct polarity and data line connection.
    • Confirm that the LED strips are compatible with the supported chip types (e.g., WS2811, WS2812B).
    • Ensure the number of pixels connected does not exceed 1024 per port.
    • Check if the LED strips have their own power supply, if required, and that it is functioning correctly.
  • Intermittent Control:
    • Inspect DMX cables for damage or loose connections.
    • Ensure proper DMX termination if you have a long DMX chain.
    • Check for electromagnetic interference from other equipment.

If problems persist, consult a qualified technician or contact customer support.

6. Specifications

FeatureSpecification
ModelH807DMX
Input VoltageDC 5-24V
Power Consumption0.2W
Operating Temperature-20°C to 85°C
Dimensions (L x W x H)164mm x 65mm x 40mm
Load Points (Max)1024 points per port (3 ports total, same data)
DMX Channels Occupied13 Channels
Supported ChipsTM1812, P943, P943S, P9411, P9412, P9883, TM1804, TM1809, UCS1903, UCS1909, UCS1912, WS2811, WS2812, WS2813, SM16703, SM16709, SM16712, INK1003, etc.

7. Warranty and Support

Specific warranty information for the Cleiscry H807 DMX512 LED Controller is not provided in this manual. Please refer to the retailer or manufacturer's website for detailed warranty terms and conditions.

For technical support or inquiries, please contact Cleiscry customer service through their official channels.

© 2024 Cleiscry. All rights reserved.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.