EVERSTEIN M6612BI-10BL

EVERSTEIN M6612BI-10BL Shower System with Tub Spout User Manual

Brand: EVERSTEIN | Model: M6612BI-10BL

1. Important Safety Information

Please read all instructions carefully before installation and use. Failure to follow these instructions may result in personal injury or property damage. Retain this manual for future reference.

2. Product Components

Verify that all components are present and undamaged before proceeding with installation.

Overview of EVERSTEIN M6612BI-10BL Shower System components

Figure 2.1: Overview of the EVERSTEIN M6612BI-10BL Shower System components, including the 10-inch rain shower head, handheld sprayer, tub spout, and control valve.

Detailed dimensions of the EVERSTEIN M6612BI-10BL Shower System components

Figure 2.2: Detailed dimensions of the shower head, shower arm, control trim, handheld shower, and tub spout.

3. Specifications

BrandEVERSTEIN
Model NumberM6612BI-10BL
ColorMatte Black
MaterialBrass, Stainless Steel
Finish TypeMatte Black Finish
Number of Handles1
Mounting TypeWall Mount
Flow Rate2.5 GPM
Maximum Pressure60 PSI
Item Weight10.5 Pounds
Head Size10 inches

4. Installation Instructions

Before starting, ensure the main water supply is turned off. This manual provides general guidance; professional installation is recommended.

4.1. Installation Video Guide

Video 4.1: Official installation guide for the EVERSTEIN Shower Tub Faucet. This video demonstrates the step-by-step process for installing the valve, trim, and various shower components.

4.2. Valve & Trim Installation

  1. Prepare the Wall: Ensure the wall framing is ready for the valve body. The valve should be positioned at a height of 43 5/8" - 51 3/16" (1100-1300mm) from the floor for the main control.
  2. Connect Water Lines: Connect the hot water inlet (left) and cold water inlet (right) to the valve body. The rainfall shower outlet is at the top, handheld shower outlet on the right, and tub spout outlet at the bottom. Standard connections are 1/2-14 NPT for USA/Canada and G1/2" for Europe.
  3. Flush Pipes: Before connecting to the valve, flush the inlet pipes for at least two minutes to remove any debris and prevent blockage.
  4. Secure Valve Body: Mount the valve body securely to the wall framing. Ensure the built-in lever is properly balanced. Make marks for drilling anchors.
  5. Pressure Test: After connecting all pipes, perform a pressure test. Flush the outlet pipes for one minute to check for appropriate water pressure.
  6. Leakage Test: Insert plugs for a water test. Ensure there is no leakage at any joint.
  7. Tile Installation: When cutting tiles, ensure the size of the cut does not exceed the dimensions of the trim. The embedded box should be cut flush with the tile surface.
  8. Install Trim: Remove the plastic protective case from the valve. Install the decorative trim plate and secure it.
Pipe connection diagram for the EVERSTEIN M6612BI-10BL Shower System

Figure 4.1: Diagram illustrating the recommended pipe replacement and connections for the rainfall shower, handheld shower, and tub spout.

Internal view of the pressure balancing valve with labeled components

Figure 4.2: Detailed view of the pressure balancing valve, showing hot water inlet, cold water inlet, rainfall shower outlet, handheld shower outlet, tub spout outlet, brass body, and ceramic valve core.

4.3. Rainfall Shower Installation

  1. Prepare Shower Arm: Ensure the distance from the tiled surface to the brass fitting is 7/8" (22mm). Wrap Teflon tape around the threads of the shower arm for at least 12 turns to prevent leaks.
  2. Install Shower Arm: Install the cover to the shower arm, then screw the shower arm clockwise into the wall fitting until secure.
  3. Attach Shower Head: Insert a gasket into the shower head connection. Connect the 10-inch rainfall shower head to the shower arm.
Wall mounted shower arm component

Figure 4.3: The wall-mounted shower arm, ready for installation.

4.4. Handheld Shower Installation

  1. Prepare Holder: Ensure the distance from the tiled surface to the brass fitting is 3/4" (20mm). Use an Allen key to remove the brass piece from the handheld shower holder by turning it counterclockwise.
  2. Install Brass Fitting: Wrap Teflon tape around the brass fitting for at least 12 turns. Mount the brass fitting into the wall.
  3. Attach Holder: Use the Allen key to turn clockwise and connect the shower bracket to the brass parts.
  4. Connect Hose and Sprayer: Insert a gasket into the hose connection. Connect the 59-inch metal hose to the handheld shower holder and then to the handheld sprayer.
Stainless steel handheld shower component

Figure 4.4: The stainless steel handheld shower, ready for connection.

59-inch stainless steel hose for handheld shower

Figure 4.5: The 59-inch stretchable metal hose for the handheld shower.

4.5. Tub Spout Installation

  1. Prepare Spout: Ensure the distance from the tiled surface to the brass fitting is 7/8" (21mm). Wrap Teflon tape around the threads of the tub spout for at least 12 turns to prevent leaks.
  2. Install Spout: Install the cover to the tub spout, then screw the tub spout clockwise into the wall fitting until secure.
Brass tub spout component

Figure 4.6: The brass tub spout, designed for efficient water flow.

5. Operating Instructions

The EVERSTEIN M6612BI-10BL shower system features a single handle for temperature control and a diverter for selecting water outlets.

Shower mixer valve control with temperature and function settings

Figure 5.1: The shower mixer valve control, showing the main handle for temperature and flow, and the diverter knob for selecting shower functions.

6. Maintenance

Regular cleaning and maintenance will ensure the longevity and optimal performance of your shower system.

7. Troubleshooting

Refer to the following table for common issues and their potential solutions.

ProblemPossible CauseSolution
Low Water PressureClogged nozzles, debris in pipes, low household water pressure.Clean shower head/handheld nozzles. Flush water lines (refer to installation). Check main water supply pressure.
Water LeaksLoose connections, worn gaskets, improper Teflon tape application.Ensure all connections are tight. Replace worn gaskets. Reapply Teflon tape correctly.
Inconsistent Water TemperaturePressure-balanced valve malfunction, issues with hot/cold water supply.Verify hot and cold water supply. If problem persists, contact customer service or a qualified plumber.
Diverter Not Switching ProperlyDebris in diverter mechanism, internal component issue.Ensure diverter knob is fully engaged in each position. If stuck or not functioning, contact customer service.

8. Warranty and Support

The EVERSTEIN M6612BI-10BL Shower System is backed by a Lifetime Warranty, which includes free parts replacement.

For technical support, warranty claims, or any questions regarding your product, please contact EVERSTEIN customer service. Our technical support team is available 24/7 to assist you.

Contact Information: Please refer to the contact details provided on the EVERSTEIN official website or your purchase documentation for the most up-to-date support information.

You can also visit the EVERSTEIN Store on Amazon for more product information and support resources.

Related Documents - M6612BI-10BL

PreviewPressure Balance Shower Faucet Installation Guide - Model W-88(ES)
Comprehensive installation manual for the Pressure Balance Shower Faucet, Model W-88(ES). Includes parts list, dimensions, installation steps, and maintenance tips. Features lifetime limited warranty information.
PreviewEVERSTEIN Thermostatic Shower Faucet Installation Manual | M6513, SFS-1065
Detailed installation manual for the EVERSTEIN Thermostatic Shower Faucet system, model numbers M6513 and SFS-1065 (W-254(ES)). This guide provides step-by-step instructions, parts lists, dimensions, maintenance tips, and warranty information for a safe and proper installation.
PreviewBalance Shower Faucet Installation Manual
This installation manual provides detailed instructions for the EVERSTEIN Balance Shower Faucet, model W-316(ES). It covers installation, parts, dimensions, maintenance, and warranty information, available in English and Spanish.
PreviewPressure Balance Shower Faucet Installation Manual - EVERSTEIN W-93(ES)
Installation manual for EVERSTEIN Pressure Balance Shower Faucet systems, including models W-93(ES), M6989-6, and M6988-6. Covers warranty, parts, dimensions, and detailed step-by-step installation instructions for single-function rain shower systems.
PreviewEverstein AquaSpa Bathtub Faucet Installation Manual W-250(ES)
This document provides comprehensive installation and maintenance instructions for the Everstein AquaSpa Bathtub Faucet, model W-250(ES). It includes a detailed parts list, step-by-step assembly guides, troubleshooting tips, and warranty information.
PreviewThermostatic Shower Faucet Installation Manual - Model W-256(ES)
Comprehensive installation and maintenance manual for the EVERSTEIN Thermostatic Shower Faucet System, Model W-256(ES), M6510-ZS, SFS-1062. Includes parts list, dimensions, installation steps, and warranty information.