AIVOLT APV24080

AIVOLT 240V 50-Amp Parallel Kit (Model APV24080) Instruction Manual

1. Introduction

This instruction manual provides essential information for the safe and effective use of your AIVOLT 240V 50-Amp Parallel Kit, model APV24080. This kit is designed to connect two compatible inverter generators to increase their combined power output, providing clean power for various electronic devices and appliances. Please read this manual thoroughly before installation and operation.

2. Safety Information

Always observe the following safety precautions to prevent injury or damage to the equipment:

  • Ensure all connections are secure and properly seated before operating.
  • Do not operate the parallel kit in wet conditions or expose it to rain.
  • Always turn off and disconnect generators before connecting or disconnecting the parallel kit.
  • Verify that your generators are compatible with the ANSI/PGMA G300-2018 Standard Parallel Link.
  • Do not exceed the maximum wattage or amperage ratings of the parallel kit or connected generators.
  • Keep children and pets away from operating generators and electrical connections.
  • In case of malfunction, immediately turn off the generators and disconnect the parallel kit.

3. Package Contents

The AIVOLT 240V 50-Amp Parallel Kit package includes:

  • AIVOLT 240V 50-Amp Parallel Kit (Model APV24080)
  • Integrated connection cables
  • Instruction Manual

4. Product Features

The AIVOLT 240V 50-Amp Parallel Kit offers the following features:

  • Clean Power: Inverter technology provides stable power suitable for sensitive electronics.
  • Toolless Installation: Designed for quick and easy clip-on connection to compatible inverter generators.
  • Increased Output: Connects two generators to double the output, supporting up to 80 amps (actual output determined by generator power).
  • Additional Outlets: Features one 240V 50A (14-50R) outlet and one 240V 30A (L6-30R) locking outlet.
  • Circuit Protection: Includes 30-amp and 50-amp circuit breakers to prevent overloads.
  • Outlet Protection: Equipped with covers to protect outlets from dust and debris.

5. Compatibility and Setup

This parallel kit is compatible with AIVOLT VS8000411 and AT20-2100001E inverter generators, as well as other brands that feature an ANSI/PGMA G300-2018 Standard Parallel Link outlet. Before purchasing, verify that your generator's parallel port is ANSI/PGMA G300-2018 compliant.

AIVOLT Parallel Kit compatibility with various generator models
Image: This diagram illustrates the compatibility of AIVOLT parallel kits (APV12080 and APV24080) with specific AIVOLT generator models (VS4350101, VS8000411, AT20-2100001E).

5.1. Connecting the Parallel Kit

  1. Prepare Generators: Ensure both inverter generators are turned off and cooled down. Place them on a stable, level surface in a well-ventilated area.
  2. Identify Parallel Ports: Locate the parallel connection ports on both generators. These ports are typically color-coded (red and black) and designed for quick connection.
  3. Connect Cables: Connect the integrated cables from the AIVOLT parallel kit to the corresponding parallel ports on each generator. Ensure the connections are firm and secure.
  4. Side view of AIVOLT parallel kit with connection cables
    Image: Side view of the AIVOLT parallel kit, showing the integrated connection cables ready for attachment to generators.
  5. Verify Port Size: The APV24080 kit supports 240V voltage and has a port size of 10.2mm / 0.4016 inches. Confirm your generator's ports match this specification.
  6. Close-up of the 10.2mm / 0.4016 inch port size for AIVOLT APV24080 parallel kit
    Image: A close-up view highlighting the 10.2mm (0.4016 inch) port size on the APV24080 parallel kit, which supports 240V operation.
  7. Example Connections:
  8. Two AIVOLT VS8000411 inverter generators connected to the 240V parallel kit
    Image: Two AIVOLT VS8000411 inverter generators successfully connected to the 240V parallel kit, capable of providing up to 12200 watts.
    Two AIVOLT AT20-2100001E inverter generators connected to the 240V parallel kit
    Image: Two AIVOLT AT20-2100001E inverter generators connected to the 240V parallel kit, capable of providing up to 16000 watts.

6. Operating Instructions

  1. Start Generators: Once the parallel kit is securely connected to both generators, start both generators according to their individual operating instructions.
  2. Engage Parallel Mode: If your generators have a parallel mode switch, ensure it is engaged.
  3. Connect Appliances: Plug your 240V appliances into the 14-50R or L6-30R outlets on the parallel kit.
  4. Power On Appliances: For optimal performance and to prevent overload, it is recommended to start devices with higher power requirements first, and then connect other devices once the initial device is running stably.
  5. Monitor Load: Pay attention to the load indicators on your generators to avoid overloading the system. The parallel kit includes 30-amp and 50-amp circuit breakers for protection.
  6. Shut Down: To turn off the system, first disconnect all appliances, then turn off the generators according to their instructions, and finally disconnect the parallel kit.

7. Maintenance

Regular maintenance ensures the longevity and safe operation of your parallel kit:

  • Cleaning: Keep the parallel kit clean and free of dust and debris. Use a dry cloth for cleaning. Do not use harsh chemicals or solvents.
  • Outlet Covers: Ensure the outlet covers are properly closed when not in use to protect against dust and moisture.
  • Cable Inspection: Periodically inspect the connection cables for any signs of wear, cuts, or damage. Replace if necessary.
  • Storage: Store the parallel kit in a dry, cool place away from direct sunlight and extreme temperatures when not in use.

8. Troubleshooting

If you encounter issues with your AIVOLT 240V 50-Amp Parallel Kit, consider the following:

  • No Power Output:
    • Ensure both generators are running correctly and producing power.
    • Check all cable connections between the parallel kit and generators for tightness.
    • Verify that the circuit breakers on the parallel kit are not tripped. Reset if necessary.
    • Confirm that the generators are in parallel mode, if applicable.
  • Overload Tripping:
    • Reduce the total load connected to the parallel kit. The combined wattage of your generators may be exceeded.
    • Ensure high-starting-wattage appliances are started one at a time.
  • Loose Connections: If power is intermittent, check all connections for looseness.

If problems persist after following these steps, please contact AIVOLT customer support.

9. Specifications

Key specifications for the AIVOLT 240V 50-Amp Parallel Kit (Model APV24080):

SpecificationValue
Model Name240V Parallel Kit (APV24080)
BrandAIVOLT
Power Source240V
Voltage240 Volts
Number of Outlets2 (14-50R, L6-30R)
Output PowerUp to 19200 Watts (dependent on connected generators)
Peak Output Power Watts5760 (This value seems low compared to 19200W output, likely refers to a single generator's peak or a specific test condition. Refer to generator manuals for combined peak output.)
Electrical Output WaveformPure Sine Wave
Frequency60 Hz
Item Dimensions (L x W x H)11.3"L x 7.2"W x 6.5"H
Item Weight2.77 Kilograms
Safety StandardUL (Energy Specifications Met)
UPC664008295877, 664008295716
AIVOLT 240V 50-Amp Parallel Kit with dimensions
Image: The AIVOLT 240V 50-Amp Parallel Kit displaying its physical dimensions: 11.3 inches in length, 7.2 inches in width, and 6.5 inches in height.

10. Warranty and Support

The AIVOLT 240V 50-Amp Parallel Kit comes with a 1-year limited warranty. AIVOLT also offers free lifetime technical support from experts.

For warranty claims, technical assistance, or any questions regarding your product, please contact AIVOLT customer support through their official channels.

Ask a question about this manual