Micsig ATO1004
Contents
Micsig ATO1004 Tablet Automotive Oscilloscope User Manual
Model: ATO1004
1. Introduction
This manual provides detailed instructions for the safe and effective use of the Micsig ATO1004 Tablet Automotive Oscilloscope. Please read this manual thoroughly before operating the device to ensure proper functionality and to prevent damage. Keep this manual for future reference.
2. Product Overview
The Micsig ATO1004 is a 4-channel tablet automotive oscilloscope designed for precise diagnostic and measurement tasks in automotive applications. It features a 10.1-inch TFT LCD capacitive touch screen, 100MHz bandwidth, 1GSa/s sampling rate, and 110Mpts memory depth. Its robust design and intuitive Android operating system facilitate efficient field work and advanced analysis.

Figure 2.1: Micsig ATO1004 Tablet Automotive Oscilloscope in operation, showing the touch interface.
Key Features:
- Smooth System: Equipped with SigtestUI professional system for full touch operation and an upgraded user interface.
- Specialized in Precision: Offers rich trigger modes, bus analysis and decoding (UART, CAN, LIN, SPI, I2C), high-pass and low-pass filtering, FFT analysis, automatic range, and segment storage.
- Rich Interface: Includes Wi-Fi, USB 3.0/2.0 Host, USB Type-C, grounding jack, HDMI, and Trigger out ports for versatile connectivity.
- Ultra-Clear Display: 10.1-inch TFT-LCD display with 1280x800 resolution and capacitive touch screen.
- Professional Automotive Functions: Supports testing of Charging/Start Circuits, Sensors, Actuators, Ignition, Networks (CAN L/H, CAN FD, LIN, Flexray, K line), and various combination tests.

Figure 2.2: Front view of the Micsig ATO1004 Tablet Oscilloscope.
3. What's in the Box
Verify that all items listed below are present in your package:
- 1 x Micsig ATO1004 Automotive Oscilloscope (with built-in battery)
- 1 x Power cable
- 2 x Test needles
- 2 x Passive probes
- 1 x Screen protector
- 1 x Adapter
- 2 x Alligator clips
- 4 x BNC banana lines
4. Setup
4.1 Charging the Battery
The ATO1004 comes with a built-in 7.4V, 7500mAh Li-ion battery. Before first use, fully charge the device using the provided power cable and adapter. Connect the adapter to the DC 12V input port on the rear of the oscilloscope.

Figure 4.1: Bottom view, indicating the battery compartment.
4.2 Powering On/Off
- To power on, press and hold the power button located on the rear panel until the screen illuminates.
- To power off, press and hold the power button until a shutdown prompt appears on the screen, then follow the on-screen instructions.
4.3 Connecting Probes and Cables
The ATO1004 features four BNC input channels and an Aux out port on the top panel. Connect the passive probes, test needles, or BNC banana lines as required for your measurement setup.

Figure 4.2: Top view showing BNC input channels.
The rear panel provides various I/O ports for connectivity:
- USB 3.0/2.0 Host: For connecting USB devices like flash drives.
- USB Type-C: For data transfer and potentially charging.
- HDMI: For external display output.
- Trigger Out: For external triggering.
- Grounding: For safety grounding.

Figure 4.3: Rear view showing I/O ports.
5. Operating Instructions
5.1 Basic Touch Screen Operation
The ATO1004 features a responsive capacitive touch screen. Use gestures such as tap, swipe, pinch-to-zoom, and drag to navigate the interface, adjust settings, and manipulate waveforms.
5.2 Waveform Acquisition and Display
After connecting your probes and powering on, the oscilloscope will display waveforms. Use the on-screen controls to adjust vertical scale (Volts/div), horizontal scale (Time/div), trigger level, and position. The device supports a high waveform capture rate for observing transient events.

Figure 5.1: Multiple waveforms displayed on the ATO1004 screen.
5.3 Advanced Measurement Functions
- Trigger Modes: Access various trigger modes (e.g., Edge, Pulse Width, Logic, Nth Edge, Runt, Slope, Time Out, Video) to stabilize and capture specific events.
- Bus Analysis and Decoding: Utilize built-in decoders for common automotive communication protocols such as UART, CAN, LIN, SPI, and I2C.
- Filters: Apply high-pass or low-pass filters to refine your signal analysis.
- FFT Analysis: Perform Fast Fourier Transform (FFT) to analyze signal frequency components.
- Automotive Specific Tests: The device supports a wide range of automotive tests including:
- Charging & Start circuits
- Sensors (e.g., ABS, Accelerator Pedal, Throttle Position, Fuel Pressure, Air Flow meter, Crankshaft, Camshaft, Knock, MAP)
- Actuators
- Ignition systems
- Networks (CAN L/H, CAN FD, LIN, Flexray, K line)
5.4 Remote Control
The ATO1004 supports remote control via Wi-Fi using a dedicated PC or smartphone application. This allows for flexible operation and monitoring from a distance.

Figure 5.2: Remote control of the ATO1004 via a smartphone application.
6. Maintenance
6.1 Cleaning
Regularly clean the device with a soft, dry cloth. For stubborn dirt, use a slightly damp cloth with a mild cleaning solution. Avoid abrasive cleaners or solvents that could damage the screen or casing. Ensure the device is powered off and disconnected from all power sources before cleaning.
6.2 Battery Care
To prolong battery life, avoid fully discharging the battery frequently. If storing the device for an extended period, ensure the battery is charged to approximately 50-70% and recharge it every few months.
6.3 Storage
Store the oscilloscope in a cool, dry place away from direct sunlight, extreme temperatures, and high humidity. Use the original packaging or a protective case to prevent physical damage.
7. Troubleshooting
7.1 Device Does Not Power On
- Ensure the battery is sufficiently charged. Connect the power adapter and try again.
- Verify the power cable and adapter are securely connected and functioning correctly.
7.2 No Waveform Displayed
- Check if probes are correctly connected to the input channels and the test point.
- Adjust the vertical scale (Volts/div) and horizontal scale (Time/div) to appropriate ranges.
- Verify the trigger settings. Ensure the trigger level is within the signal's amplitude.
- Confirm the input signal is present and within the oscilloscope's measurement capabilities.
7.3 Touch Screen Unresponsive
- Restart the device.
- Ensure the screen is clean and free of debris or moisture.
7.4 Wi-Fi Connectivity Issues
- Ensure Wi-Fi is enabled on the device.
- Check network settings and ensure the device is connected to the correct network.
- Verify the remote control application on your PC or smartphone is up-to-date and correctly configured.
8. Specifications
| Feature | Specification |
|---|---|
| Model | ATO1004 |
| Bandwidth | 100MHz |
| Channels | 4 |
| Sampling Rate | 1GSa/S (single channel) |
| Memory Depth | 110Mpts (single channel) |
| Rise Time | ≤3.5ns |
| Waveform Capture Rate (Max) | 78,000 wfms/s |
| Input Sensitivity Range | 1mV/div ~ 10V/div (1MΩ); 1mV/div ~ 10V/div (50Ω) |
| Bandwidth Filter | Full bandwidth, Low pass (to 30KHz) |
| Input Impedance | 1MΩ |
| Timebase Range | 2ns/div ~ 1ks/div |
| Trigger Types | Edge, Pulse Width, Logic, Nth Edge, Runt, Slope, Time Out, Video |
| Bus Decoding | UART, CAN, CAN FD, LIN, SPI, I2C |
| Advanced Math | Sqrt(), Abs(), Deg(), Rad(), Exp(), Diff(), In(), Sine(), Cos(), Tan(), Intg(), Log(), Arcsin(), Arccos(), Arctan() |
| Interfaces | Wi-Fi, USB 3.0/2.0 Host, USB Type-C, Grounding, HDMI, Trigger out |
| Storage | 32GB internal storage |
| Display | 10.1" TFT LCD capacitive touch screen, 1280*800 pixels, 11*10 grids |
| Battery | 7.4V, 7500mAh, Li-ion battery (5H duration) |
| Dimension / Net Weight | 265*192*50mm / 1.9kg (with battery) |

Figure 8.1: Technical specifications overview.
9. Warranty and Support
For warranty information and technical support, please refer to the documentation provided with your purchase or contact the manufacturer directly. Keep your proof of purchase for warranty claims.