Introduction
The Aritech Advisor Advanced Secure (ATS1136) is a sophisticated security system keypad designed for advanced control and monitoring of your security installation. This manual provides comprehensive instructions for its setup, operation, maintenance, and troubleshooting, ensuring optimal performance and security.
Product Overview

Figure 1: Aritech Advisor Advanced Secure (ATS1136) Keypad
This image displays the front panel of the Aritech Advisor Advanced Secure (ATS1136) keypad. It features a monochrome LCD screen showing 'Aritech' and the date/time '04/01/2021 09:48'. Above the screen are indicator LEDs for power, alerts, and system status. To the right of the screen is a numeric keypad (0-9, *, ?) and function keys (F, X, home icons). A central navigation cluster with directional arrows and a checkmark/hash button is also visible. Three oval buttons labeled A, B, and C are located below the screen.
Setup
1. Installation Guidelines
- Ensure the keypad is installed in a dry, secure location, away from direct sunlight and extreme temperatures.
- Mount the keypad at an accessible height for all users.
- Refer to the separate installation guide for wiring and power connections.
2. Initial Power-Up
- Connect the keypad to the main control panel as per the wiring diagram.
- Apply power to the system. The keypad display should illuminate.
- The system will perform a self-test. Wait for the display to show the default screen or a prompt for initial setup.
3. Basic Configuration (Date/Time)
Upon first power-up or after a power loss, you may need to set the date and time.
- Press the MENU button.
- Navigate to "System Settings" using the arrow keys.
- Select "Date/Time" and enter the current date and time using the numeric keypad.
- Confirm the settings by pressing the CHECK button (center of navigation cluster).
Operating Instructions
1. Arming the System
To arm the security system:
- Full Arm: Enter your user code and press the HOME icon button (top right).
- Part Arm (Stay Arm): Enter your user code and press the PARTIAL HOME icon button (second from top right).
- The system will provide an exit delay countdown. Ensure all protected areas are clear before the delay expires.
2. Disarming the System
To disarm the security system:
- Enter your user code when prompted or upon entry.
- The system will disarm, and the status indicator will change.
3. Viewing System Status
The display provides real-time system status. Key indicators include:
- Green LED (Power): Indicates power is supplied.
- Red LED (Alert): Indicates an alarm or fault condition.
- Display Messages: Provide detailed information on zones, faults, and system events.
4. Using Function Keys (A, B, C, F, X)
- A, B, C Buttons: These are programmable quick-action buttons. Their function depends on your system configuration (e.g., panic, medical alert, specific zone bypass).
- F Button: Typically used for 'Function' or 'Fire' related actions, depending on system programming.
- X Button: Used for 'Clear' or 'Exit' functions, to cancel an entry or go back in a menu.
Maintenance
1. Cleaning the Keypad
- Use a soft, dry, lint-free cloth to clean the display and keypad surface.
- Do not use abrasive cleaners, solvents, or spray directly onto the keypad.
2. Battery Backup
The main control panel typically includes a battery backup. The keypad will indicate low battery status if applicable. Consult a qualified technician for battery replacement.
3. System Testing
Regularly test your security system as recommended by your installer. This typically involves:
- Testing all sensors (doors, windows, motion detectors).
- Verifying communication with the monitoring station (if applicable).
- Checking siren functionality.
Troubleshooting
| Problem | Possible Cause | Solution |
|---|---|---|
| Keypad display is blank. | No power to the keypad or control panel. | Check power supply to the control panel. Ensure all connections are secure. Contact a technician if the issue persists. |
| System will not arm. | A zone is open (e.g., door/window open) or a fault exists. | Check the keypad display for open zones or fault messages. Close all open zones. Clear any fault conditions as indicated. |
| False alarms. | Improper sensor placement, environmental factors, or faulty sensor. | Review sensor placement. Ensure pets or drafts are not triggering motion sensors. Contact a technician to inspect sensors. |
| Keypad buttons unresponsive. | Temporary software glitch or hardware issue. | Try restarting the system (if safe to do so, consult your installer). If unresponsive, contact a qualified technician. |
For issues not listed here, or if solutions do not resolve the problem, please contact your security system installer or Aritech customer support.
Specifications
| Feature | Detail |
|---|---|
| Brand | Aritech |
| Model Number | ATS1136 |
| Product Type | Security System Keypad |
| Display Type | Monochrome LCD |
| Keypad Type | Numeric with Function Keys |
| ASIN | B0BYMXRYNS |
| Date First Available (Amazon.com.be) | March 2, 2023 |
Warranty and Support
For warranty information, please refer to the documentation provided with your complete security system or contact your authorized Aritech dealer/installer. Aritech products are typically covered by a limited warranty against defects in materials and workmanship.
For technical support, service, or replacement parts, please contact your security system installer. They are best equipped to provide assistance specific to your installation and system configuration. You can also visit the official Aritech website for general product information and support resources.