1. Introduction
The ANENG A3005 Pen Type Multimeter is a compact, intelligent, and multi-functional electrical testing instrument. It is designed to provide accurate and reliable measurements for a wide range of electrical parameters, making it an indispensable tool for professionals and hobbyists alike. Its pen-style design ensures portability and ease of use in various settings.
2. Safety Information
Please read all safety warnings and instructions carefully before using this product. Failure to follow these instructions may result in electric shock, fire, or serious injury.
- Always ensure the device is in good working condition before use.
- Do not attempt to measure voltages or currents exceeding the specified maximum ratings.
- Use caution when working with live circuits. Always assume circuits are live until proven otherwise.
- Do not use the device if it appears damaged or if the test leads are frayed or broken.
- Keep the device away from water and moisture.
- Replace batteries promptly when the low battery indicator appears.
- Always disconnect the test leads from the circuit before changing functions or turning off the device.
3. Package Contents
Verify that all items are present in your package:
- 1 x ANENG A3005 Pen Type Multimeter
- 1 x Test Lead
- 2 x 1.5V AAA Batteries
- 1 x User Manual (this document)
4. Product Overview
The ANENG A3005 is designed for ease of use and portability. Below are the key components and their functions:

Figure 4.1: Main view of the ANENG A3005 Pen Type Multimeter, including the main unit, test lead, and two AAA batteries.

Figure 4.2: Overview of the multimeter's functions, including AC/DC voltage, buzzer, resistance, NCV, Live wire detection, flashlight, auto power-off, audible/visual alarm, low battery indication, backlight, and data retention.

Figure 4.3: The A3005 combines the capabilities of a traditional multimeter and a voltage tester into one convenient pen-style device.

Figure 4.4: The non-contact voltage (NCV) detection feature allows for safe voltage detection without direct contact with conductors.

Figure 4.5: The integrated bright flashlight assists in taking measurements in dimly lit environments.

Figure 4.6: The device is powered by two AAA batteries, easily accessible for replacement.

Figure 4.7: The A3005 in use, demonstrating its application in testing electrical circuits within a panel.
5. Setup
5.1 Battery Installation
The ANENG A3005 requires two 1.5V AAA batteries for operation. Batteries are included in the package.
- Locate the battery compartment cover on the back of the multimeter.
- Slide the cover open in the direction indicated by the arrow.
- Insert the two AAA batteries, ensuring correct polarity (+ and -) as marked inside the compartment.
- Close the battery compartment cover securely.

Figure 5.1: Connect the black test lead to the COM port on the multimeter.
5.2 Test Lead Connection
Connect the included test lead to the multimeter. The black test lead should be inserted into the COM (Common) port. The red test lead (integrated into the pen tip) is the positive input.
6. Operating Instructions
6.1 Power On/Off
Press the Power button (usually marked with a power symbol) to turn the device on. The device will automatically enter Auto mode. To turn off, press and hold the Power button. The device also features an automatic shutdown function after 5 minutes of inactivity to conserve battery life.
6.2 Function Selection
The A3005 operates primarily in an intelligent Auto mode, which automatically identifies the measurement type (AC/DC voltage, resistance, continuity). For specific functions like NCV or Live wire detection, use the SELECT button.
- AC/DC Voltage Measurement: In Auto mode, simply touch the test leads to the circuit. The device will automatically detect and display the voltage.
- Resistance Measurement: In Auto mode, touch the test leads to the component. The device will measure and display resistance.
- Continuity Test: In Auto mode, touch the test leads to the circuit points. If continuity exists, the device will beep.
- Capacitance Measurement: The device supports capacitance testing. In Auto mode, connect the test leads across the capacitor.
- Diode Test: In Auto mode, connect the test leads across the diode.
- Non-Contact Voltage (NCV) Detection: Press the SELECT button to cycle to NCV mode. Hold the tip of the multimeter near a live wire or electrical outlet. The device will indicate the presence of AC voltage with an audible alarm and visual indicator.
- Live Wire Detection: Press the SELECT button to cycle to Live mode. Insert the red probe into the live wire. The device will indicate if it's a live wire.

Figure 6.1: The multimeter supports multiple test functions including AC/DC voltage, buzzer, resistance, and NCV detection.
6.3 Backlight and Flashlight
- Backlight: Single press the HOLD button to toggle the display backlight on/off.
- Flashlight: Long press the SELECT button to turn the built-in flashlight on/off.
6.4 Data Hold
Press the HOLD button to freeze the current reading on the display. Press it again to release the data hold function.
7. Maintenance
7.1 Cleaning
Wipe the device with a dry, soft cloth. Do not use abrasive cleaners or solvents. Ensure the device is off and disconnected from any power source before cleaning.
7.2 Storage
When not in use for an extended period, remove the batteries to prevent leakage. Store the multimeter in a cool, dry place, away from direct sunlight and extreme temperatures.
7.3 Probe Tip Replacement
The probe tip can be replaced if damaged or for specific applications. Gently unscrew the existing tip and screw in the new one.

Figure 7.1: The probe tip can be replaced for maintenance or specific testing needs.
8. Troubleshooting
- Device does not power on: Check if batteries are installed correctly and have sufficient charge. Replace batteries if necessary.
- Inaccurate readings: Ensure test leads are properly connected. Verify the correct measurement mode is selected (if not in Auto mode). Clean the probe tips and connection ports.
- No NCV detection: Ensure the device is in NCV mode. The NCV function requires proximity to an AC voltage source.
- Display is dim or flickering: Batteries may be low. Replace them.
9. Specifications
| Feature | Specification |
|---|---|
| Brand | ANENG |
| Model | A3005 |
| Measurement Accuracy | 1.0% ± 5 digits |
| AC Voltage Range | 0.8V - 600V |
| DC Voltage Range | 0.8V - 600V |
| Resistance Range | 0.1Ω - 40MΩ |
| Non-Contact Voltage Detection | Yes |
| Live Wire Detection | Yes |
| Continuity Test | Yes |
| Capacitance Test | Yes |
| Diode Test | Yes |
| Display Counts | 4000 Counts |
| Power Source | 2 x 1.5V AAA Batteries |
| Auto Power Off | Yes (after 5 minutes of inactivity) |
| Item Weight | 130 g |
| Package Dimensions | 19.7 x 6 x 3.2 cm |
10. Warranty and Support
ANENG electrical testers come with a lifetime warranty and technical support. For any issues or inquiries, please contact ANENG customer service through the retailer or the official ANENG website.