1. Introduction
Thank you for choosing the AIVOLT VS2000101 Inverter Generator. This manual provides essential information for the safe operation, maintenance, and troubleshooting of your generator. Please read this manual thoroughly before operating the generator to ensure proper use and to prevent injury or damage.
The AIVOLT VS2000101 is a portable and quiet inverter generator designed to provide clean and stable power for various applications, including camping, outdoor activities, and as a backup power source.
2. Safety Information
WARNING: Failure to follow these safety instructions could result in serious injury or death.
- Carbon Monoxide Hazard: Generators produce carbon monoxide, a colorless, odorless, poisonous gas. Operate the generator outdoors in a well-ventilated area, far away from windows, doors, and vents. Never operate indoors, in a garage, or in any enclosed space.
- Fire Hazard: Fuel is highly flammable. Refuel in a well-ventilated area with the engine off and cooled. Do not smoke or allow open flames near the generator. Store fuel in an approved container in a safe location.
- Electrical Shock Hazard: Do not operate the generator in wet conditions. Ensure all electrical connections are dry and secure. Never touch electrical components with wet hands.
- Hot Surfaces: The generator engine and muffler become very hot during operation and remain hot for a period after shutdown. Avoid touching hot surfaces to prevent burns.
- Children and Pets: Keep children and pets away from the generator, especially during operation.
- Grounding: Always properly ground the generator before operation to prevent electrical shock.
- Read the Manual: Always read and understand the entire user manual before attempting to operate or service the generator.
3. Product Overview
The AIVOLT VS2000101 Inverter Generator is designed for portability and efficient power delivery. Key features include ultra-quiet operation, clean electricity output (less than 3% THD), Eco-Mode for fuel efficiency, and parallel capability for increased power.
3.1 Generator Components

Figure 3.1: Main view of the AIVOLT VS2000101 Inverter Generator, showcasing its compact and portable design with the control panel on the right side.

Figure 3.2: Overview of key features including ultra-quiet operation (<59dB), clean electricity (<3% THD), Eco-Mode, parallel readiness, 80CC powerful engine, and long run time.

Figure 3.3: Demonstrates the portability of the generator, highlighting its lightweight design (15kg) for easy transport.
3.2 Control Panel

Figure 3.4: Detailed view of the control panel, showing all outlets, switches, and indicator lights.
- Fuel Switch (Multi-Switch): Controls fuel flow and engine operation modes (OFF, RUN, START CHOKE).
- DC 5V USB Outlets: Two USB Type-A ports and one USB Type-C port for charging small electronic devices.
- DC 12V Outlet: For 12V DC appliances.
- AC 230V Outlet: Standard AC outlet for 230V appliances.
- Low Idle Switch (Eco-Mode): Engages Eco-Mode for reduced fuel consumption and noise when power demand is low.
- Parallel Ports: Allows connection of two identical generators for increased power output (requires a parallel kit, sold separately).
- ESC (Engine Stop Control) / 9A (Circuit Breaker): Engine stop switch and 9 Amp circuit breaker for DC output.
- GND (Ground Terminal): For connecting the generator to an earth ground.
- Output Ready Indicator: Illuminates when the generator is producing stable power.
- Overload Indicator: Illuminates and may shut down the generator if the connected load exceeds its capacity.
- Oil Warning Indicator: Illuminates if the engine oil level is too low, and will shut down the engine to prevent damage.
3.3 Included Accessories

Figure 3.5: The generator comes with essential accessories: a spark plug wrench, a screwdriver, a 12V battery charging cable, and an oil funnel.
- Spark Plug Wrench
- Screwdriver
- 12V Battery Charging Cable
- Oil Funnel
4. Setup
Before starting the generator, perform the following setup steps:
- Unpacking: Carefully remove the generator and all accessories from the packaging. Inspect for any shipping damage.
- Add Engine Oil:
- Place the generator on a level surface.
- Remove the oil filler cap/dipstick.
- Using the provided oil funnel, slowly add 0.35 liters of 10W30 engine oil.
- Check the oil level with the dipstick; it should be at the upper mark. Do not overfill.
- Securely replace the oil filler cap.
- Add Fuel:
- Ensure the generator is off and cooled.
- Open the fuel tank cap.
- Fill the fuel tank with fresh, unleaded petrol (gasoline). Do not use E85 or other alternative fuels.
- Do not overfill; leave space for fuel expansion.
- Securely close the fuel tank cap.
- Grounding: Connect a grounding wire (not included) from the generator's ground terminal to a suitable earth ground. This is crucial for safety.
5. Operating Instructions
5.1 Starting the Generator
- Ensure the generator is on a level surface and all electrical loads are disconnected.
- Turn the Fuel Switch (Multi-Switch) to the "START CHOKE" position.
- Grasp the recoil starter handle firmly and pull it slowly until resistance is felt, then pull quickly and smoothly.
- Once the engine starts, slowly move the Fuel Switch to the "RUN" position.
- Allow the engine to warm up for a few minutes. The "Output Ready" indicator light should illuminate.
5.2 Connecting Electrical Devices
- Ensure the "Output Ready" light is on before connecting devices.
- Plug your 230V AC appliances into the AC 230V outlet.
- Plug your 12V DC appliances into the DC 12V outlet.
- Connect USB devices to the DC 5V USB ports.
- Do not exceed the generator's rated wattage (1700W running, 1800W starting). If the "Overload" indicator illuminates, disconnect some devices.
5.3 Eco-Mode Operation
To conserve fuel and reduce noise during periods of low power demand, activate the Low Idle Switch (Eco-Mode). In Eco-Mode, the engine speed will automatically adjust to match the load, improving fuel efficiency.
5.4 Parallel Operation

Figure 5.1: Two AIVOLT VS2000101 generators connected for parallel operation, allowing for double the power output.
The AIVOLT VS2000101 generator is "Parallel Ready," meaning two identical units can be connected using a parallel kit (sold separately) to double the available power. Refer to the parallel kit's instruction manual for detailed connection and operation procedures.
5.5 Stopping the Generator
- Disconnect all electrical loads from the generator.
- Allow the generator to run for a few minutes without load to cool down.
- Turn the Fuel Switch (Multi-Switch) to the "OFF" position.
6. Maintenance
Regular maintenance is crucial for the longevity and reliable operation of your generator. Always ensure the generator is off and cooled before performing any maintenance.
6.1 Maintenance Schedule
| Item | Initial (First Use) | Every 25 Hours / 1 Month | Every 100 Hours / 6 Months |
|---|---|---|---|
| Engine Oil | Change after 5 hours | Change | Change |
| Air Filter | Inspect | Clean | Clean |
| Spark Plug | Inspect | Inspect | Inspect and Adjust Gap / Replace |
| Fuel Filter | - | - | Inspect / Replace |
6.2 Storage
For extended storage (more than 30 days), prepare the generator as follows:
- Drain all fuel from the fuel tank and carburetor. Run the engine until it stops from lack of fuel.
- Change the engine oil.
- Remove the spark plug and pour a tablespoon of clean engine oil into the cylinder. Slowly pull the recoil starter a few times to distribute the oil, then reinstall the spark plug.
- Clean the exterior of the generator.
- Store the generator in a clean, dry, well-ventilated area.
7. Troubleshooting
This section outlines common issues and their potential solutions. If you encounter a problem not listed here, or if the suggested solutions do not resolve the issue, contact customer support.
| Problem | Possible Cause | Solution |
|---|---|---|
| Engine will not start | No fuel Low oil level Fuel switch in wrong position Spark plug issue | Add fresh fuel Add engine oil (check Oil Warning light) Move fuel switch to "START CHOKE" then "RUN" Inspect/clean/replace spark plug |
| No power output | Overload Circuit breaker tripped "Output Ready" light off | Reduce connected load (check Overload light) Reset circuit breaker Ensure generator is running stably and warmed up |
| Engine stops during operation | Low oil level Out of fuel Overload | Check Oil Warning light, add oil Add fuel Check Overload light, reduce load |
8. Specifications
| Parameter | Value |
|---|---|
| Model | VS2000101 |
| Brand | AIVOLT |
| Starting Watts | 1800W |
| Running Watts | 1700W |
| Rated Wattage | 1700W |
| Max Output Wattage | 1800W |
| AC Voltage | 230V |
| DC Voltage | 12V |
| USB Output | 5V (Type-A, Type-C) |
| Engine Type | 80CC |
| Fuel Type | Unleaded Petrol |
| Oil Type | 10W30 |
| Oil Capacity | 0.35 Liters |
| Weight | 15 kg |
| Dimensions (L x W x H) | 470 x 275 x 410 mm |
| Noise Level | <59dB |
9. Warranty and Support
AIVOLT products are manufactured to high-quality standards. For warranty information, technical support, or to order replacement parts, please contact AIVOLT customer service through your retailer or the official AIVOLT website. Please have your model number (VS2000101) and purchase date available when contacting support.