LYCEBELL E2-QX1201

LYCEBELL Digital Manometer Gas Pressure Tester User Manual

Model: E2-QX1201

1. Introduction

The LYCEBELL Digital Manometer (Model: E2-QX1201) is a professional-grade dual-port air pressure meter engineered for high-precision measurement of gas pressure and temperature. This versatile device supports 12 different measurement units and includes a backlight display for clear readability in various conditions. Its robust design and advanced features make it an essential tool for gas measurement and calibration, HVAC system troubleshooting, laboratory testing, and maintenance of gas appliances.

LYCEBELL Digital Manometer with tubes and connector

Figure 1.1: LYCEBELL Digital Manometer E2-QX1201

Key features of the manometer including handheld, dual-port, data record, 12 units, auto shut-down, and low battery reminder

Figure 1.2: Key Features of the Digital Manometer

2. What's in the Box

Upon opening the package, please verify that all the following components are included and in good condition:

  • 1 x Digital Manometer Unit
  • 1 x Tool Bag
  • 1 x Flexible Tube
  • 1 x Hose Connector
  • 1 x Set of Batteries
  • 1 x User Manual
Contents of the product package including the manometer, tool bag, flexible tube, hose connector, batteries, and user manual

Figure 2.1: Package Contents

Video 2.1: Unboxing and Package Contents (0:09 - 0:23)

3. Setup

3.1 Battery Installation

To power on your manometer, you will need to install the included 9V battery. Follow these steps:

  1. Locate the battery compartment cover on the back of the device.
  2. Gently slide the cover downwards to open the compartment.
  3. Insert the 9V battery, ensuring the correct polarity (+ and -) as indicated inside the compartment.
  4. Close the battery compartment cover by sliding it back into place until it clicks securely.
Front and back view of the manometer with numbered parts, showing the battery compartment on the back

Figure 3.1: Rear View of Manometer with Battery Compartment

Video 3.1: Battery Installation (0:24 - 0:36)

4. Operating Instructions

4.1 Button Functions

Familiarize yourself with the control buttons on the front panel of the manometer:

Close-up of the manometer's LCD screen and control buttons

Figure 4.1: Manometer Display and Buttons

  • Power On/Off Button (): Press to turn the device on or off.
  • UNITS Button: Press to switch between the 12 available pressure units (Pa, KPa, psi, kgcm², ozin², bar, mbar, mmHg, inHg, inH₂O, ftH₂O, cmH₂O). Press and hold for over 2 seconds to clear stored data.
  • HOLD Button: In power-on status, press to hold the current reading on the display. Press and hold for over 2 seconds to make the reading zero (tare function).
  • DIF Button: Press to look up stored data.
  • MAX Button: Press to look down stored data. Press and hold to enter Max/Min measuring mode.
  • °C/°F Button: Press to store up to 100 data points.

Video 4.1: Button Descriptions and Functions (0:37 - 1:16)

4.2 Connecting Tubes

The manometer features two tube connectors for differential pressure measurement:

  • Tube Connector (+): For positive pressure input.
  • Tube Connector (-): For negative pressure input.

Connect the flexible tubes to these ports as required for your measurement application. Ensure a secure fit to prevent leaks and ensure accurate readings.

Close-up of the dual-port connectors on the manometer, showing tube connection points

Figure 4.2: Dual-Port Connectors

Video 4.2: Tube Connection (1:16 - 1:20)

5. Applications

The LYCEBELL Digital Manometer is suitable for a wide range of applications requiring precise pressure measurement and analysis. Its high accuracy and multiple units make it adaptable to various industrial and scientific needs.

  • Gas Measurement and Calibration: Essential for verifying and calibrating gas systems.
  • HVAC Systems: Ideal for troubleshooting and maintaining heating, ventilation, and air conditioning systems.
  • Gas Appliance Repair and Installation: Used to ensure proper pressure settings and detect leaks in gas appliances.
  • Laboratory Testing: Provides accurate pressure readings for experimental setups.
  • Blower and Clean Room Monitoring: Measures airflow and pressure differentials in controlled environments.
  • Boiler Maintenance: Assists in checking and adjusting boiler pressure for optimal performance and safety.
Manometer shown in various application settings including clean rooms, furnaces, boilers, blowers, and HVAC systems

Figure 5.1: Diverse Applications of the Manometer

Video 5.1: Wide Application Examples (1:20 - 1:40)

6. Maintenance

To ensure the longevity and accuracy of your LYCEBELL Digital Manometer, follow these maintenance guidelines:

  • Cleaning: Wipe the device with a soft, dry cloth. Do not use abrasive cleaners or solvents.
  • Storage: Store the manometer in its protective tool bag in a cool, dry place away from direct sunlight and extreme temperatures.
  • Battery Care: Remove the battery if the device will not be used for an extended period to prevent battery leakage and damage.
  • Tube Inspection: Regularly inspect the flexible tubes for cracks, kinks, or blockages that could affect readings. Replace if necessary.

7. Troubleshooting

If you encounter issues with your manometer, refer to the following common problems and solutions:

  • Device Does Not Turn On:
    • Check if the battery is installed correctly with the right polarity.
    • Replace the battery with a new 9V battery.
  • Inaccurate Readings:
    • Ensure the tubes are securely connected and free from leaks or blockages.
    • Perform a zero adjustment using the HOLD button (press and hold for 2 seconds).
    • Verify that the correct measurement unit is selected.
  • Display is Dim or Flickering:
    • The battery may be low. Replace the battery.
  • Cannot Store Data:
    • Ensure the device is in the correct mode for data storage (refer to °C/°F button function).
    • The memory might be full. Clear stored data by pressing and holding the UNITS button for 2 seconds.

8. Specifications

Detailed technical specifications for the LYCEBELL Digital Manometer:

FeatureValue
Product Dimensions5.31 x 2.17 x 1.1 inches
Item Weight4.52 ounces
Model NumberE2-QX1201
ManufacturerLYCEBELL
Country of OriginChina
Power Source9V Battery (included)
DisplayLCD with Backlight
Measurement Units12 (Pa, KPa, psi, kgcm², ozin², bar, mbar, mmHg, inHg, inH₂O, ftH₂O, cmH₂O)
Data StorageUp to 100 data points
Table showing units, range, and resolution for the manometer

Figure 8.1: Measurement Units, Range, and Resolution

9. Warranty and Support

LYCEBELL products are manufactured to high-quality standards. For warranty information or technical support, please refer to the contact details provided in the original product packaging or visit the official LYCEBELL website. Keep your purchase receipt as proof of purchase for warranty claims.

Related Documents - E2-QX1201

Preview ATuMan and DUKA Product Overview - Tools and Electronics
Explore the range of high-tech, design-focused electronic and power tools from DUKA, and well-designed, high-quality hand tools from ATuMan. Featuring laser rangefinders, temperature and humidity meters, socket testers, and more.
Preview Keto-Mojo GK+ Meter Error Codes: Meanings and Solutions
Comprehensive guide to understanding and resolving error codes (E1-E11, HI, LO) displayed on the Keto-Mojo GK+ Meter. Find solutions for common issues like incorrect strips, samples, temperature, low battery, and high/low readings.
Preview Rex Service Menu: Machine Maintenance and Error Codes
Comprehensive guide to Rex coffee machine service, detailing error codes, their descriptions, and the Steam-Safety test procedure. Includes maintenance advice and safety regulations.
Preview Joyoung Y-50C19 Pressure Cooker Troubleshooting Guide
A comprehensive troubleshooting guide for the Joyoung Y-50C19 electric pressure cooker, detailing common faults, their causes, and recommended solutions for issues such as lid closure problems, steam leaks, float valve errors, and digital display alarms.
Preview OMRON R7 Automatic Wrist Blood Pressure Monitor: User Manual and Guide
Comprehensive user manual for the OMRON R7 Automatic Wrist Blood Pressure Monitor. Learn how to measure blood pressure, use memory functions, understand readings, and troubleshoot common errors.
Preview Water Heater Troubleshooting Guide: Error Codes and Solutions
This guide provides detailed troubleshooting steps for water heater error codes (E0-E8, En), including possible causes and fault handling. It also covers non-defect conditions and common operational queries.