Contents
NJOY Keen 600 VA 360 W UPS User Manual
Model: UPLI-LI060KE-CG01B
1. Product Overview
The NJOY Keen UPS series is designed to provide essential backup power and protection for your electronic devices against common power anomalies such as surges, spikes, brownouts, and blackouts. This Line-interactive UPS features Automatic Voltage Regulation (AVR) to stabilize incoming power and a simulated sine wave output suitable for most home and office electronics. It ensures continuous operation for critical equipment like PCs, modems, routers, and TVs during power interruptions.

Figure 1.1: The NJOY Keen 600 UPS unit, showcasing its compact tower design and front panel with power button and indicator light.
2. Setup and Installation
2.1 Unpacking and Inspection
Carefully unpack the UPS and inspect it for any shipping damage. If any damage is found, do not operate the unit and contact your dealer. The package should contain the UPS unit and this user manual.
2.2 Placement
Place the UPS in a clean, cool, and well-ventilated area. Avoid direct sunlight, heat sources, and excessive moisture. Ensure there is adequate space around the unit for proper airflow. The UPS should be placed on a stable, flat surface.
2.3 Initial Charging
Before initial use, connect the UPS to a standard wall outlet and allow it to charge for at least 8 hours. This ensures the internal battery is fully charged and ready to provide optimal backup time. The UPS will charge whether it is turned on or off.
2.4 Connecting Equipment
Connect your computer, monitor, modem, router, or other critical electronic devices to the Schuko outlets on the rear of the UPS. Ensure that the total power consumption of connected devices does not exceed the UPS's capacity (360W for the 600VA model). Do not connect laser printers or shredders to the UPS, as their high surge current can overload the unit.

Figure 2.1: Rear view of the NJOY Keen 600 UPS, showing the two Schuko outlets for connecting protected devices.
3. Operation
3.1 Powering On/Off
To turn on the UPS, press and hold the power button on the front panel for a few seconds until you hear a beep and the indicator light illuminates. To turn off the UPS, press and hold the power button again until the indicator light turns off.
3.2 Indicator Lights
The NJOY Keen 600 UPS features an LED indicator on the front panel:
- Green LED On: The UPS is operating in AC mode, providing power to connected devices and charging the battery.
- Green LED Flashing and Beeping: The UPS is operating on battery power due to a power outage or significant voltage fluctuation. The beeping indicates battery mode.
- Green LED Off: The UPS is off or not receiving input power.

Figure 3.1: Front panel of the NJOY Keen UPS, highlighting its power button and indicator light, along with icons representing its key features: two Schuko outlets, auto-restart function, and simulated sine wave output.
3.3 Line-Interactive Technology and AVR
The Line-interactive mode allows the UPS to regulate voltage over a wide range without switching to battery mode. The Automatic Voltage Regulation (AVR) system automatically corrects minor voltage fluctuations (sags and surges) in incoming power, providing stable and clean power to your connected devices and extending battery life by reducing unnecessary battery usage.
3.4 Simulated Sine Wave Output
The NJOY Keen UPS produces a simulated sine wave output when operating on battery power. This waveform is suitable for most electronic devices, including computers, monitors, and networking equipment. It provides a cost-effective solution while closely approximating the utility power waveform.
3.5 Auto-Restart Function
The UPS is equipped with an auto-restart function. After a complete power outage and once utility power is restored, the UPS will automatically restart and resume providing power to connected devices, ensuring seamless operation without manual intervention.
3.6 Battery Runtime
The battery runtime depends on the load connected to the UPS. Higher loads will result in shorter backup times. Refer to the typical runtime graph below for an estimate.

Figure 3.2: A graph illustrating the estimated battery runtime of the NJOY Keen UPS at various load percentages, indicating longer runtime at lower loads. For example, at 25% load, the runtime is approximately 19 minutes, while at 100% load, it is less than 1 minute.
4. Maintenance
4.1 Battery Care
The UPS contains a sealed lead-acid battery. To maximize battery life:
- Keep the UPS connected to AC power at all times to keep the battery charged.
- Avoid frequent deep discharges.
- Store the UPS in a cool, dry place if not in use for extended periods. Recharge the battery every 3-6 months to prevent permanent damage.
- Battery replacement should only be performed by qualified service personnel.
4.2 Cleaning
Clean the exterior of the UPS with a soft, dry cloth. Do not use liquid or aerosol cleaners. Ensure ventilation openings are free from dust and debris.
5. Troubleshooting
If the UPS is not operating correctly, refer to the following table for common issues and solutions:
| Problem | Possible Cause | Solution |
|---|---|---|
| UPS does not turn on. | Battery discharged or not connected to AC power. | Connect the UPS to a wall outlet and allow it to charge for at least 8 hours. Ensure the power cord is securely plugged in. |
| UPS beeps continuously in battery mode. | Battery is low or overloaded. | Save your work and shut down connected equipment immediately. Reduce the load by disconnecting non-essential devices. |
| Short backup time. | Battery not fully charged or battery nearing end of life. | Ensure the UPS is charged for 8 hours. If the issue persists after charging, the battery may need replacement. |
| UPS does not provide power to connected devices. | UPS is off or in fault mode. | Ensure the UPS is turned on. Check if the total load exceeds the UPS capacity. If the problem persists, contact support. |
If the problem persists after attempting these solutions, please contact NJOY customer support.
6. Specifications
| Feature | Description |
|---|---|
| Model | UPLI-LI060KE-CG01B |
| Phase | Single-phase |
| Technology | Line-interactive (VI) |
| Type | Tower |
| Output Waveform | Simulated Sine Wave |
| Power (VA/W) | 600 VA / 360 W |
| Input Nominal Voltage | 230 V AC |
| Input Voltage Range | 162 ~ 290 V AC |
| Input Frequency | 50 Hz / 60 Hz (Auto-sensing) |
| Output Nominal Voltage | 230 V AC |
| Output Voltage Accuracy | ± 10% |
| Outlets | 2 x Schuko |
| Battery Type | 1 x 12 V - 7 Ah Sealed Lead-Acid |
| Noise Level | < 40 dB |
| Color | Black |
| Material | Alloy Steel |
| Compatible Devices | DVR and video surveillance systems, Wi-Fi ADSL/Fiber Modem, Monitor, Printer (non-laser), TV, Desktop Computer, Gaming Computer |
7. Warranty and Support
NJOY offers a comprehensive warranty for the Keen series UPS:
- UPS Unit: 3-year warranty
- Internal Battery: 1-year warranty
Our professional customer service team is dedicated to providing prompt and quality support. If you require assistance or have any questions before, during, or after your purchase, please do not hesitate to contact NJOY customer support. Refer to your purchase documentation or the NJOY website for specific contact details.
Documents and downloads
Ask a question about this manual
Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.