Pulsar PGD95BISCO

Pulsar PGD95BISCO Inverter Generator User Manual

Model: PGD95BISCO | Brand: Pulsar

1. Introduction

This manual provides essential information for the safe and efficient operation, maintenance, and troubleshooting of your Pulsar PGD95BISCO Super Quiet Dual Fuel Portable Inverter Generator. Designed for home use backup, RV readiness, and various portable power needs, this generator offers reliable power with advanced features like remote control, electric start, and comprehensive safety shut-offs.

2. Safety Information

Operating a generator safely is paramount to prevent injury or property damage. Always read and understand all safety warnings and instructions before use.

  • Carbon Monoxide (CO) Hazard: Generators produce carbon monoxide, an odorless, colorless, and poisonous gas. Operate the generator outdoors only, far away from windows, doors, and vents. Never operate it inside a home, garage, shed, or any partially enclosed space. The PGD95BISCO features a CO Sentry system that automatically shuts off the generator if carbon monoxide levels become too high.
  • Fire Hazard: Fuel is highly flammable. Store gasoline in approved containers in a well-ventilated area away from ignition sources. Do not refuel a hot or running engine. Ensure proper ventilation when using propane.
  • Electrical Shock Hazard: Never operate the generator in wet conditions. Ensure all electrical connections are secure and dry. Do not overload the generator.
  • Hot Surfaces: The generator's engine and muffler become very hot during operation and remain hot for some time after shutdown. Avoid contact with hot surfaces.
  • Grounding: Always properly ground the generator before operation to prevent electrical shock. Refer to local electrical codes for specific grounding requirements.

3. Product Overview

The Pulsar PGD95BISCO is a powerful and versatile inverter generator designed for various applications. It features dual fuel capability, allowing operation on either gasoline or propane.

Key Features:

  • Super Quiet 62 dBA Operation
  • Dual Fuel Capability (Gasoline & LPG)
  • 9500 Peak Watts / 7600 Rated Watts (Gasoline)
  • 8550 Peak Watts / 7200 Rated Watts (LPG)
  • Electric Start, Remote Control, and Recoil Start options
  • CO Sentry Carbon Monoxide Detection with Auto Shut-off
  • Low Battery and Low Oil Shutoff for engine protection
  • Multiple Outlets: 120V/240V 30A/50A, 120V 20A (x4), USB-A, USB-C
  • 6.9 Gallon Fuel Tank for extended run time (up to 9.5 hours at half load)
  • Low Idle Mode for fuel efficiency

Component Identification:

Main view of the Pulsar PGD95BISCO Inverter Generator
Figure 3.1: Main view of the Pulsar PGD95BISCO Inverter Generator, showcasing its overall design and portability.
Front view of the Pulsar PGD95BISCO Inverter Generator
Figure 3.2: Front view of the generator, highlighting the control panel with various outlets and switches.
Side view of the Pulsar PGD95BISCO Inverter Generator
Figure 3.3: Side view of the generator, showing its robust frame and integrated wheels for easy transport.
Rear view of the Pulsar PGD95BISCO Inverter Generator
Figure 3.4: Rear view of the generator, providing a perspective of its exhaust and cooling vents.
Detailed view of the generator's control panel
Figure 3.5: Detailed view of the generator's control panel, labeling various switches, outlets, and display indicators for user interaction.
Close-up of the generator's side panel, emphasizing the CO Sentry and Dual Fuel features
Figure 3.6: Close-up of the generator's side panel, emphasizing the CO Sentry (Carbon Monoxide Protection) and Dual Fuel capabilities.
Graphic emphasizing the Super Quiet operation and Clean Electricity output
Figure 3.7: Graphic emphasizing the 'Super Quiet' operation and 'Clean Electricity' output, making it safe for sensitive electronics.

4. Setup

Before first use, proper setup is crucial for safe and effective operation.

4.1 Unpacking and Initial Inspection:

  • Remove the generator from its packaging and inspect for any shipping damage.
  • Ensure all included accessories are present.

4.2 Adding Engine Oil:

  • The generator is shipped without engine oil. Add the recommended type and amount of oil before starting. Refer to the oil fill cap or engine specifications for details.
  • Use the provided oil funnel and ensure the generator is on a level surface.

4.3 Adding Fuel:

  • Gasoline: Use fresh, unleaded gasoline with an octane rating of 87 or higher. Do not use E85 or any gasoline containing more than 10% ethanol. Fill the fuel tank carefully, avoiding spills.
  • Propane (LPG): Connect a standard 20lb or 40lb propane tank to the LPG inlet using a compatible hose. Ensure all connections are tight to prevent leaks.
  • Always add fuel in a well-ventilated area, away from ignition sources.

4.4 Grounding the Generator:

  • For safe operation, the generator must be properly grounded. Connect a grounding wire from the generator's grounding terminal to a suitable earth ground, such as a ground rod.

5. Operating Instructions

Follow these steps for starting and operating your Pulsar PGD95BISCO generator.

5.1 Starting the Generator:

  • Preparation: Ensure the generator is on a level surface, outdoors, and away from any obstructions. Check oil and fuel levels.
  • Fuel Source Selection: Turn the Fuel Source dial to the desired fuel (Gasoline or LPG).
  • Main Switch: Turn the Main SW to the 'ON' position.
  • Starting Methods:
    • Electric Start: Press and hold the 'ENGINE START/STOP' button until the engine starts.
    • Remote Start: Use the provided remote control. Press the start button on the remote.
    • Recoil Start: If electric start is unavailable, pull the recoil handle firmly and smoothly until the engine starts.
  • Allow the engine to warm up for a few moments before connecting loads.

5.2 Low Idle Mode:

  • The 'LOW IDLE' switch allows the generator to automatically adjust engine speed based on the load, improving fuel efficiency and reducing noise.
  • Turn the 'LOW IDLE' switch to 'ON' for optimal fuel consumption when running light loads. Turn 'OFF' for full power output or when starting high-demand appliances.

5.3 Connecting Electrical Devices:

  • Connect your appliances or power cords to the appropriate outlets (120V AC, 240V AC, 30A, 50A, USB-A, USB-C).
  • Ensure the total wattage of connected devices does not exceed the generator's rated running wattage.
  • The '120V ONLY' switch allows you to select between 120V only output or 120V/240V output. For full power from all outlets, ensure it is set correctly for your needs.

5.4 Stopping the Generator:

  • Disconnect all electrical loads.
  • Press the 'ENGINE START/STOP' button or turn the Main SW to 'OFF'.
  • If using LPG, close the valve on the propane tank.

6. Maintenance

Regular maintenance ensures the longevity and reliable performance of your generator.

6.1 Routine Checks:

  • Before Each Use: Check engine oil level, fuel level, and inspect for any visible damage or leaks.
  • Every 25 Hours or Annually: Change engine oil.
  • Every 50 Hours or Annually: Clean or replace air filter, inspect spark plug.
  • Every 100 Hours or Annually: Inspect fuel filter, clean spark arrestor.

6.2 Fuel Storage:

  • For long-term storage (over 30 days), drain the gasoline from the fuel tank and carburetor, or use a fuel stabilizer.
  • Propane does not degrade like gasoline, making it a good option for extended storage.

7. Troubleshooting

This section provides solutions for common operational issues.

ProblemPossible CauseSolution
Engine will not startNo fuel, low oil, spark plug issue, fuel valve closed, Main SW OFFAdd fuel, check oil level, inspect/clean spark plug, open fuel valve, turn Main SW ON
No power outputCircuit breaker tripped, overload, Eco-mode engaged with high load, 120V ONLY switch settingReset circuit breaker, reduce load, turn Low Idle OFF, check 120V ONLY switch
Engine runs roughStale fuel, dirty air filter, spark plug issueReplace fuel, clean/replace air filter, inspect/clean spark plug
CO Sentry shuts off generatorHigh carbon monoxide levels detectedMove generator to a well-ventilated outdoor area. Allow area to clear before restarting.

8. Specifications

Detailed technical specifications for the Pulsar PGD95BISCO Inverter Generator.

SpecificationValue
BrandPulsar
Model NamePulsar 9500W Duel Fuel Inverter Generator
Part NumberPGD95BISCO
Wattage (Peak)9500 Watts (Gasoline) / 8550 Watts (LPG)
Wattage (Running)7600 Watts (Gasoline) / 7200 Watts (LPG)
Fuel TypeGasoline, Propane
Engine Type4 Stroke, 458cc OHV
Voltage120 Volts, 240 Volts
Frequency60 Hz
Tank Volume6.9 Gallons
Runtime (Half Load)9.5 hours
Item Weight281 Pounds
Product Dimensions (L x W x H)29.5" x 22.7" x 29.5"
Total Power Outlets8
Special FeaturesElectric Start, Super Quiet, Dual Fuel, Low Battery / Low Oil Shutdown, Remote Start, CO Sentry

9. Warranty and Support

Pulsar stands behind its products with a comprehensive warranty and customer support.

9.1 Warranty Information:

The Pulsar PGD95BISCO Inverter Generator comes with a 3-year limited warranty. Please refer to the warranty card included with your product for full terms and conditions, including coverage details and limitations.

9.2 Customer Support:

For technical assistance, parts, or warranty claims, please contact Pulsar customer support. Keep your model number and purchase date readily available when contacting support.

For general inquiries or to find more information, you may visit the official Pulsar website or refer to the contact details provided in your product packaging.

Related Documents - PGD95BISCO

Preview Pulsar 9500 Watt Dual Fuel Inverter Generator Operator's Manual
This operator's manual provides comprehensive instructions for the Pulsar PGD95BiSCO 9500 Watt Dual Fuel Inverter Generator, covering safety precautions, operation, maintenance, and troubleshooting.
Preview Pulsar PG4500BiSRCO Inverter Generator Operator's Manual
Operator's manual for the Pulsar PG4500BiSRCO Inverter Generator, covering safety, features, operation, maintenance, and troubleshooting for gasoline and LPG dual-fuel use.
Preview Pulsar PGX60BISRCO 6000 Watt Inverter Generator Operator's Manual
This operator's manual provides comprehensive instructions for the Pulsar PGX60BISRCO 6000 Watt Dual Fuel Inverter Generator. It covers essential safety information, preparation steps, operating procedures, maintenance schedules, troubleshooting tips, and technical specifications to ensure safe and efficient use.
Preview Pulsar 1600 Watt Inverter Generator Operator's Manual PGD16iSCO
Comprehensive operator's manual for the Pulsar PGD16iSCO 1600 Watt Inverter Generator. Includes detailed safety instructions, operating procedures, maintenance schedules, troubleshooting guides, and technical specifications for safe and efficient use.
Preview Pulsar GD400BN 4000 Watt Dual Fuel Inverter Generator Operator's Manual
Comprehensive operator's manual for the Pulsar GD400BN 4000 Watt Dual Fuel Inverter Generator, covering safe operation, maintenance, troubleshooting, and technical specifications for gasoline and propane use.
Preview Pulsar 10000 Watt Dual Fuel Generator Owner's Manual PG10000B
Comprehensive owner's manual for the Pulsar 10000 Watt Dual Fuel Generator (Model PG10000B), covering safety, operation, maintenance, troubleshooting, and specifications for both gasoline and LPG use.